• Title/Summary/Keyword: 하프늄

Search Result 22, Processing Time 0.024 seconds

Effect of Insertion of Hf layer in Al oxide tunnel barrier on the properties of magnetic tunnel junctions (알루미늄 산화물 절연막에 하프늄의 첨가가 자기터널접합의 특성에 미치는 영향)

  • Lim, W.C.;Bae, J.Y.;Lee, T.D.;Park, B.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • We have investigated the effect of Hf insertion in the Al oxide tunnel barrier on the properties of magnetic tunnel junctions (MTJs). MTJs with Hf inserted barrier show the higher tunnel magnetoresistance (TMR) ratio and less temperature and bias voltage dependence of TMR than MTJs with a conventional Al$_2$O$_3$ barrier. The enhancement of TMR ratio and the reduction of the temperature and bias voltage dependence might be due to the reduction of defects in the barrier. Al-Hf oxide was formed by depositing Al and Hf simultaneously, and oxidizing the compound films. The TMR ratio of 36% was almost the same value as that with Hf inserted barrier. This implies that the inserted Hf layers mixed with Al layers during deposition or oxidation, and they might form Al Hf oxide barriers. This compound Al Hf oxide formation may be responsible to reduction of defect concentration which enhanced the TMR ratio and reduced temperature and bias-voltage dependence.

Thermal/Mechanical Properties of Hafnium Carbide Coatings on Carbon-Carbon Composites (탄소-탄소 복합재료의 하프늄 탄화물 코팅재의 열적/기계적 특성)

  • Choi, So-dam;Seo, Hyoung-IL;Lim, Byung-Joo;Sihn, Ihn Cheol;Lee, Jung Min;Park, Jong Kyoo;Lee, Kee Sung
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.260-266
    • /
    • 2018
  • This study investigates thermal and mechanical characterization of Hafnium carbide coating on the $C_f-C$ composites. The hafnium carbide coatings by vacuum plasma spray on the C/C-SiC composites are prepared to evaluate oxidation and wear resistance. We perform the thermal durability tests by thermal cycling at $1200^{\circ}C$ for 10cycles in air and investigates the weight change of each cycle. We also evaluate the wear and indentation behavior using tungsten carbide ball indenter as a mechanical evaluation. As a result, the HfC coating is beneficial to reduce of weight loss during thermal cycling test and improve the elastic property of C/C-SiC composite. Especially, the HfC coating improves the wear resistance of C/C-SiC composite.

Solvent Extraction of Zr(IV) and Hf(IV) from Sulfuric Acid Solutions by Acidic Extractants and Their Mixtures with TBP (황산용액에서 양이온계 추출제 및 TBP와의 혼합추출제에 의한 지르코늄(IV)과 하프늄(IV)의 용매추출)

  • Wang, Ling Yun;Lee, Man Seung
    • Resources Recycling
    • /
    • v.25 no.2
    • /
    • pp.3-9
    • /
    • 2016
  • Separation of Zr(IV) and Hf(IV) from sulfuric acid solutions was investigated by extraction with several acidic extractants such as Versatic acid, LIX 63, and Cyanex 301. From strong sulfuric acid solutions, the separation of Zr(IV) and Hf(IV) by Versatic acid and LIX 63 was not possible, while selective extraction of Hf(IV) over Zr(IV) was obtained with Cyanex 301. However, the extraction percentage of the two metals was much lower compared to that by D2EHPA. Mixing of TBP with Cyanex 301 and D2EHPA led to negative effect on the extraction and separation of the two metal ions. The difference in the extraction reaction and separation selectivity between HCl, $HNO_3$ and $H_2SO_4$ media with each extractant was discussed.

Solvent Extraction of Zirconium and Hafnium from Hydrochloric Acid solution by LIX 63 and Cyanex 301 (염산용액(鹽酸溶液)에서 LIX 63 및 Cyanex 301에 의한 지르코늄과 하프늄의 용매추출(溶媒抽出))

  • Min, Soo-Hwan;Lee, Man-Seung
    • Resources Recycling
    • /
    • v.22 no.6
    • /
    • pp.19-25
    • /
    • 2013
  • Solvent extraction experiments have been conducted to separate Zr(IV) and Hf(IV) from chloride solutions by using LIX63 and Cyanex301. Zr and Hf were extracted by cation exchange reaction in the pH range from 1 to 4 by the extratants. Since the extraction percentage of the two metals was similar to each other, it was difficult to separate the two metals by using LIX63 or Cyanex301. Use of a mixture of LIX63/TBP or Cyanex301/TBP resulted in antagonism in our experimental ranges. Our data showed that there is some possibility of separating the two metals by the mixture of Cyanex301 and TBP because the extraction percentage of Hf decreased more rapidly than that of Zr as HCl concentration was decreased. The mixture of LIX63 and Cyanex301 had little effect on the separation of the two metals.

A Study on the Defect Annealing of Hafnium Metal By Positron Annihilation Techniques (양전자소멸기법을 이용한 하프늄금속의 격자결함 회복에 관한 연구)

  • Kang, Myung-Soo;Jung, Sung-Hoon;Yoon, Young-Ku;Park, Yong-Ki
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.71-79
    • /
    • 1993
  • Positron annihilation characteristics and microhardness of 25% cold worked and isochronally annealed hafnium specimens were measured to study recovery and recrystallization stages of hafnium specimens. The annihilation lifetime of positrons in hafnium has been measured for the distinct cases of annihilation in the annealed lattice and annihilation after trapping at lattice defects generated by cold deformation at room temperature. The annihilation lifetime in the annealed lattice was 187 $\pm$3.7 psec, whereas it was 217 $\pm$ 4.2 psec for positrons trapped at deformation-induced defects (mostly dislocations). The changes in Doppler broadening and hardness showed similar trend in the recrystallization range, however, the measured value of Doppler broadening variation were quite sensitive to changes in the recovery region in which the variation in hardness value was completely insensitive. Recovery of cold worked hafnium initiated at about 623 K and recrystallization occurred at around 1023 K.

  • PDF

A Study on Improvement of the Ablation Resistance of Two Types of the Carbon/Carbon Composites by HfC Coating (하프늄카바이드 코팅을 통한 2종형상의 탄소/탄소복합재의 내삭마성 향상연구)

  • Kang, Bo-Ram;Kim, Ho-Seok;Oh, Phil-Yong;Choi, Seong-Man
    • Composites Research
    • /
    • v.33 no.4
    • /
    • pp.205-212
    • /
    • 2020
  • In this study, HfC was coated on two types of carbon/carbon composites coated with SiC by vacuum plasma spraying(VPS). The experiment was performed using a plasma wind tunnel with heat flux of 5.06 MW/㎡ for 120 s heat flux before and after the coating. The mass ablation rate was calculated through the mass change before and after the test, and the length change was measured by using calipers and high speed camera. The oxidation/ablation behavior were observed by FE-SEM with EDS analysis of the specimens cross section. The plasma wind tunnel test results showed that the coated specimens had low weight loss and length change, and high oxidation/ablation resistance. However, two types of the specimens tested under the same conditions were different in the ablation behavior and ablation rate, and it was evaluated that the cylindrical type had higher oxidation/ablation resistance.