• Title/Summary/Keyword: 하천이격거리

Search Result 30, Processing Time 0.394 seconds

Experimental Study on the Adjustment Processes of a Series of Mining Pits in the Dredged Channels (준설하천에서 직렬로 배열된 웅덩이의 적응에 관한 실험적 연구)

  • Jang, Chang-Lae;Lee, Gi-Ha
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.4
    • /
    • pp.385-395
    • /
    • 2011
  • The adjustment processes and responses of a series of mining pits by sand or gravel mining were investigated by laboratory experiments. The filling processes of the two pits were affected by the bars developed in the upstream of the channel. However, the bars were not developed and the bed was degradated in the downstream of the pits due to little sediment flow, which was trapped in the pits. The submerged angle of repose in the pits was nearly constant when the pits were being filled. After the filling processes of the pits were finished, the pit was speedily filled with sediment, and the bed was aggradated and migrated with speed. However, the angle of repose decreased. As the distance between the upstream pit and the downstream pit increased, the bed of the pit downstream was tailcutted and degradated. The migration speed of the pit decreased. However, the dimensionless pit depth increased as the distance between the pits increased. The dimensionless pit depth increased with time.

Effects of Vane Distance from Outer Bank on Bed Variation in Curved Channel (날개형 수제의 이격거리가 만곡부 하상변동에 미치는 영향)

  • Jeon, Woo Sung;Park, Sang Deog;Park, Ho Kook
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.135-135
    • /
    • 2019
  • 수제는 만곡부의 유로 조정이나 하상보호와 같은 하천공학적인 목적을 가진 수공구조물이다. 본 연구에서는 개수로 만곡부에 수제 설치 시 외측벽과 수제 사이의 거리에 따라 하상변동이 어떤 차이가 있는지를 파악하기 위해 이동상 수리실험을 했다. 본 연구에서는 폭 1.45 m, 길이 24 m인 $90^{\circ}$ 만곡수로에 $4.2{\times}8.4cm$의 직사각형 단면 수제를 외측으로부터 이격하여 2열로 설치하였다. 하상재료는 $d_{50}$이 3.3 mm인 잔자갈을 사용했고 하상경사는 1/300로 하였다. 실험은 평균 유량 163 l/s를 3시간 동안 공급했고, 종료 후 만곡부의 주요횡단면별 하상고를 측정했다. 여기서 실험별 이격거리는 8.4 cm, 14 cm, 19.6 cm로 하였다. 실험 결과 외측벽과 수제 사이의 거리가 멀어질수록 만곡부의 최대세굴심은 커지고 그 발생 위치는 하류로 이동하는 경향을 보였다. 만곡부 최대세굴이 발생한 횡단면 형상은 만곡 내측에서 외측방향으로 무차원 위치 $y_1$(=내측에서의거리/폭)가 0.27보다 작으면 퇴적에 의해 하상이 상승하고, 0.35보다 클 때는 세굴에 따른 하상저하가 나타났다. 만곡 외측벽 부근 하상은 이격거리가 짧을수록 수제 설치에 의한 하상고 변화가 작았다.

  • PDF

Thalweg Change According to Outer-bank Distance of the Submerged Vane in Curved Channel (날개형 수제의 이격거리에 따른 개수로 만곡부의 유심선 변화)

  • Ham, Gwang Hyeon;Jeon, Woo Sung;Sim, Young Ju;Park, Sang Deog
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.261-261
    • /
    • 2021
  • 자연하천은 직선하천보다 만곡하천으로 존재하는 경우가 많다. 하천의 만곡부에서 2차류 흐름과 나선형 흐름, 원심력이 수충부와 외측제방에 작용하여 하상에 국부적인 세굴이 발생한다. 세굴이 발생하게 되면 수충부나 외측제방에 붕괴나 피해가 일어날 수 있다. 세굴의 피해를 줄이고 만곡부유로를 조정하기 위해 날개형 수제를 설치할 수 있다. 날개형 수제를 설치한 하상은 수제의 두께, 길이, 높이, 간격, 위치, 배열 등에 따라 다르게 반응한다. 본 연구에서는 만곡 개수로에 잠긴 날개형 수제를 설치할 때 만곡 외측에서 수제 열까지의 거리가 만곡부의 유심선 변화에 미치는 영향을 이동상 개수로 수리실험으로 조사하였다. 이동상 수리실험은 폭 1.16 m, 깊이 1 m, 길이 24 m인 90° 만곡 개수로에 d50이 3.3mm인 잔자갈을 깔아 하상경사 1/300로 정리한 후 수제를 설치하는 순서로 이루어졌다. 수제는 폭 20mm, 길이 70mm의 직사각형 단면 목재로 제작하여 설치하였고, 실험별 이격거리는 외측 제방으로부터 8.4 cm, 14 cm, 19.6 cm로 하였다. 실험유량은 140l/s로 3시간 동안 흘린 뒤 하상측정장치를 이용하여 주요 횡단면별 하상고를 측정하였다. 측정한 데이터를 이용하여 최심하상고의 크기와 위치, 유심선의 변화 등을 분석하였다.

  • PDF

Experimental Study on Debris Reduction Effects Verification by Deflector (우회말뚝을 이용한 유송잡물 저감효과 검증실험)

  • Kim, Sung Joong;Kang, Jun Gu;Kim, Jong Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.513-513
    • /
    • 2017
  • 홍수 시 하천을 따라 유하되는 유송잡물은 구조물에 집적을 통해 유수의 흐름을 방해하고 구조물 주변의 지반을 약화시키거나 월류로 인한 심각한 피해를 야기 시킨다. 교량의 경우 유송잡물의 집적은 교각의 항력을 증가시켜 전도파괴를 유발시킬 수 있으며, 교각주변 흐름교란을 통한 하상 세굴로 인해 기초부를 파괴시키기도 한다. 또한 통수단면적 증가로 인해 높아진 수위는 제방월류로 인해 재산 및 인명피해를 유발하기도 한다. 본 연구는 이러한 유송잡물의 집적을 억제시키는 저감시설물을 대상으로 연구를 수행하고자 한다. 유송잡물 저감시설 중 우회말뚝을 대상으로 수리모형실험을 수행하고 실규모 실험을 통해 저감효과를 검토하였다. 우회말뚝은 교각 전면부에 상류방향으로 이격되어 설치되는 말뚝형태의 구조물로 유송잡물의 우회를 통해 교각에 집적을 저감하는 목적으로 설치된다. 본 연구에서는 수리실험 및 실규모실험을 통해 우회말뚝의 저감능력 검토를 수행하였으며, 1개의 말뚝을 대상으로 교각과의 이격거리와의 관계를 검토하고자 하였다. 수리모형실험의 결과 유송잡물의 길이가 경간장의 100% 일 경우 저감시설이 없을 경우 교각에 87.6% 집적이 발생하였으나 말뚝이 설치되었을 경우 교각에 직접적으로 집적되는 유송잡물은 없으며 31.7% 유송잡물은 우회말뚝에 집적되는 것으로 나타났다. 실규모 실험의 경우 우회말뚝이 없는 경우 집적률은 60%의 집적이 이루어졌으나 우회말뚝을 설치한 경우 10%의 집적률로 나타났다. 우회 말뚝설치에 따른 저감효과는 발생하였으나 이격거리에 대한 저감능력의 차이는 없는 것으로 나타났다. 그러나 우회말뚝의 이격거리가 길어질수록 말뚝주변에서 회전되어진 유송잡물이 교각에 간헐적으로 집적되는 현상이 관측되었다. 따라서 말뚝의 위치를 선정하기 위해서는 유송잡물의 길이를 고려하여 설치하는 것이 유리할 것으로 판단된다.

  • PDF

Analysis of Stream Depletion due to Groundwater Pumping in Variable Stream Stages Using an Analytical Model (해석적 모형을 이용한 지하수 양수 및 하천수위 변화에 따른 하천수 감소 특성 분석)

  • Lee, Jeongwoo
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.439-449
    • /
    • 2019
  • To prevent the drying-out of streams and to make effective use of stream water and groundwater, it is necessary to evaluate the impact of groundwater pumping on nearby streams. To this end, stream depletion due to groundwater pumping should be investigated in terms of various hydraulic characteristics of the aquifer and stream. This study used the Baalousha analytical solution, which accounts for stream-stage variation over time, to analyze stream depletion due to groundwater pumping for cases where the stream level decreases exponentially and recovers after the decrease. For conditions such as an aquifer transmissivity of 10~100 ㎡ d-1, storage coefficient 0.05~0.3, streambed hydraulic conductance 0.1~1.0 m d-1, stream-well distance 100~500 m, and stage recession coefficient 0.1~1.0 d-1, the contribution of stream water (the dimensionless ratio of stream water reduction rate to groundwater pumping rate) was analyzed in cases where stream level change was considered. Considering the effect of stream-stage recession, the contribution of stream water is greatly reduced and is less affected by the stream-depletion factor, which is a function of the stream-to-well distance and hydraulic diffusivity. However, there is no significant difference in stream depletion under constant- and variable-stage recovery after recession. These results indicate that stream level control can distribute the relative impacts on stream water and aquifer storage during groundwater pumping

Assessment of Streamflow Depletion Due to Groundwater Pumping from a Well (단일 관정 지하수 양수에 따른 하천수 감소량 평가)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1079-1088
    • /
    • 2013
  • Groundwater pumping from a well has different impacts on streamflow depletion because hydraulic properties of the aquifer and the stream bed differ depending on its location. Therefore, quantitative assessment of streamflow depletion due to each groundwater pumping with different well locations is needed for the effective groundwater development and streamflow management. In this study, a watershed-based surface water and groundwater integrated model, SWAT-MODFLOW was used to assess the streamflow depletion near stream reach due to groundwater pumping from a well located within the Sinduncheon watershed. The arbitrary 50 wells among the currently used groundwater pumping wells were selected within the study area and the streamflow responses to each groundwater pumping were simulated at nearby and downstream reaches. In particular, the applicability of the Stream Depletion Factor (SDF) and Stream Bed Factor (SBF), which are widely used for evaluating the degree of streamflow depletion due to groundwater pumping, was evaluated. The simulated results demonstrated that the streamflow depletion rate divided by the pumping rate significantly differ depending on well locations and distance between well and stream, showing a wide range of values from below 20% to above 90%. From the simulated results, it was found out that the SDF or the SBF can be a partial referred value but not an absolute criterion in determining whether a pumping well has a great impact on streamflow depletion or not.

Study on the Distribution Characteristics of Storm Damage Area : The Case of Gyeonggi-do (수해지 분포 특성에 관한 연구 : 경기도 사례를 중심으로)

  • Kang, Sangjun;Jung, Juchul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.507-517
    • /
    • 2012
  • The main purpose of this study is to address flooding resilient land use management strategy based on the distributional characteristics of storm damage areas in Gyeonggi-do. The employed methods are 1) Exploratory Spatial Data Analysis (ESDA) to understand the spatial patterns of storm damage areas occurred from 2005 to 2009, 2) Local Indicator of Spatial Association (LISA) to examine spatial autocorrelation existed in storm damage areas for the year of 2009. The results show that 1) crop land damage is very sensitive to heavy precipitation, 2) damaged buildings are found in all over the Gyeonggi areas, but relatively more damages are in the regions closed to the City of Seoul, 3) damaged roads-bridges, streams, and reaches are found in mostly rural areas, 4) building and crop land damage occurs mostly in lowlands with different spatial patterns. These findings imply that 1) it will be useful to consider the average distances and slopes of damaged building and crop lands from streams for the decision making of land use management strategy, 2) further management efforts are required in the north, east, and south regions of Gyeonggi areas to prevent roads-bridge, stream, and reach damages, 3) the present land use pattern needs to be carefully investigated by considering the damage clustered areas for the year of 2009 based on watershed and municipality boundaries.

Estimation of streamflow depletion from groundwater pumping using Hunt's analytical solution (Hunt 해석해를 이용한 지하수 양수에 따른 하천수 감소량 산정)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won;Lee, Min Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.327-327
    • /
    • 2016
  • 하천 인근에서 지하수를 채수할 경우 지하수위 저하로 인해 하천으로의 지하수 유출이 감소하거나 하천수가 역으로 지하수계로 유입되어 하천수 감소(stream depletion) 현상이 발생한다. 이러한 지하수 양수로 인한 하천수 감소량을 산정하기 위한 방법으로 현지 계측, 수치해석 모델링, 해석해 적용 등이 있으며, 이 중에서 해석해를 이용하는 방법은 실제 하천수-지하수 연계시스템을 단순화한 조건에서 유도되었다는 단점이 있지만 비용이나 시간적 측면에서는 가장 유리하다. 본 연구에서는 Hunt(1999)가 개발한 해석해를 전산프로그램화하고 이를 하천변에 위치한 실제 지하수 관정 109개에 적용하여 양수로 인한 지하수위 강하 및 하천수 감소량을 산정하여 대수층 및 하천의 수리특성, 하천과 관정간의 이격거리에 따른 변동 특성을 분석하였다. Hunt 해석해로 양수 시간에 따른 하천수 감소량을 계산한 결과, 양수후 5년 뒤에는 지하수 양수량 대비 하천수 감소량의 비율이 80%를 초과하는 관정이 대부분인 것으로 나타났으며, 특히 수리확산계수가 $1,000m^2/d$를 넘고 하천고갈인자(Stream Depletion Factor, SDF)값이 100 보다 작은 범위에서는 양수의 영향이 크게 발생하는 것으로 분석되었다.

  • PDF

Simulation of Groundwater Flow and Sensitivity Analysis for a Riverbank Filtration Site in Koryeong, Korea (경북 고령군 강변여과 취수 지역의 지하수 유동 모사 및 민감도 분석)

  • Won, Lee-Jung;Koo, Min-Ho;Kim, Hyoung-Su
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.2
    • /
    • pp.45-55
    • /
    • 2006
  • A 2-D unconfined flow model is developed to analyze annual variations of groundwater level and bank filtration rate (BFR) for an experimental riverbank filtration site in Koryeong, Korea. Two types of boundary conditions are examined for the river boundary in the conceptual model: the static head condition that uses the average water level of the river and the dynamic cyclic condition that incorporates annual fluctuation of water level. Simulations show that the estimated BFR ranges $74.3{\sim}87.0%$ annually with the mean of 82.4% for the static head boundary condition and $52.7{\sim}98.1%$ with the mean of 78.5% for the dynamic cyclic condition. The results illustrate that the dynamic cyclic condition should be used for accurate evaluation of BFR. Simulations also show that increase of the distance between the river and the pumping wells slightly decreases BFR up to 4%, and thereby indicate that it is not a critical factor to be accounted for in designing BFR of the bank filtration system. A sensitivity analysis is performed to examine the effects of model parameters such as hydraulic conductivity and specific yield of the aquifer, recharge rate, and pumping rate. The results demonstrate that the average groundwater level and BFR are most sensitive to both the pumping rate and the recharge rate, while the water level of the pumping wells is sensitive to the hydraulic conductivity and the pumping rate.

Estimation of streamflow depletion due to groundwater pumping using analytical and numerical models (해석적 모형과 수치적 모형을 이용한 지하수 양수로 인한 하천수 감소량 산정)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won;Hong, Sung Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.294-294
    • /
    • 2018
  • 복잡한 수문 수리지질학적 조건을 고려할 수 있는 SWAT-MODFLOW 지표수-지하수 통합모형과 대수층-하천-양수정 시스템을 단순화한 Hunt (1999) 해석해를 죽산천 인근 지역에 각각 적용하여 지하수 양수로 인한 하천수 감소량을 모의하고 그 결과를 비교하였다. 하천으로부터 약 1 km 이내에 위치한 천부 지하수 관정들 중에서 취수계획량이 $100m^3$/일을 초과하는 18개의 관정을 선별하고 지하수 양수량 대비 하천수 감소량(하천수 감소비)을 산정한 결과 대부분의 관정에서 해석해와 모델링 결과의 차이가 0.2 미만으로 매우 작은 것으로 나타났다. 따라서 해석해가 하천-대수층 시스템을 단순화한 조건에 대해 유도되었음에도 불구하고 정밀한 모델링에 준하는 결과를 나타낼 수 있는 것으로 분석되었다. 그러나, 양수기간이 장기화되거나 하천과 관정간의 이격거리가 증가함에 따라 해석해와 모의결과의 차이가 다소 증가하는 경향을 나타내었다. 해석해가 대수층 저류량의 감소와 하천수량의 감소가 장기적으로 균형을 이루는 동적 평형 상태를 구현할 수 없고 하천수위의 급격한 변화에 따른 하천수와 지하수간의 상호 교환량의 불규칙한 패턴 또한 모사할 수 없는 한계가 있지만 양수기간 5년 이내의 하천수 감소량의 평균적인 거동은 수치모의 결과와 유사한 것으로 평가되었다.

  • PDF