• Title/Summary/Keyword: 하중진폭

Search Result 167, Processing Time 0.025 seconds

Low Cycle Fatigue Behavior of Longitudinal Reinforcement (축방향철근의 저주파 피로 거동)

  • Lee, Jae-Hoon;Ko, Seong-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.263-271
    • /
    • 2010
  • The purposes of this study is to verify the fracture characteristic of steel which is manufactured in Korea, subjected to cyclic loading. This investigation deals with the low cycle fatigue behavior of longitudinal reinforcement in reinforced concrete bridge substructure (piles and columns of piers). Eighty-one specimens of longitudinal reinforcement were tested under axial strain controlled reversed cyclic tests with strain amplitudes. The selected test variables are ratio of tension strain to compression strain, yield stress of longitudinal reinforcement, ratio of diameter of longitudinal steel to clear length of longitudinal steel, size of longitudinal steel and strain amplitudes. Low cycle fatigue behavior and low-cycle fatigue life are investigated and discussed in this paper.

Simplified Static Analysis of Superstructure on Very Large Floating Structures subjected to Wave Loads (파랑하중을 받는 초대형 부유식 구조물 상부구조체의 실용정적해석법)

  • Song, Hwa-Cheol;Park, Hyo-Seon;Seo, Ji-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.27 no.5
    • /
    • pp.519-526
    • /
    • 2003
  • For preliminary structural analysis of superstructures on very large floating structures(VLFS), superstructures are analyzed considering elastic deformations of barge type lower-structures subjected to wave loads. In this case, to consider the effect of wave loads on the superstructure, initial displacements at the support points of superstructures are evaluated as input data for the analysis. However, the evaluation and application of displacement loads are tedious and very time-consuming processes. Therefore, this paper proposes a simplified static analysis method to analyze the structural behaviors of superstructures on very large floating structures subjected to wave loads. In this study, the member forces due to the variation of beam span and the amplitude and period of wave load are analyzed by using an example 4 span -3 story structure and the amplification factors for beam moments are represented by the specific regression equation.

Variation of Moving Dynamic Vehicle Loads According to Surface Smoothness of Pavement Systems (도로포장 표면평탄성에 따른 주행차량의 동적 하중 변화 특성)

  • Kim, Seong-Min;Rhee, Suk-Keun
    • International Journal of Highway Engineering
    • /
    • v.10 no.1
    • /
    • pp.135-144
    • /
    • 2008
  • The dynamic loads imposed by moving vehicles have variations in the magnitude due to the surface roughness of the pavement systems and the larger dynamic loads than the design loads may affect the pavement performance. This paper presents variations of the moving dynamic vehicle loads due to the pavement surface roughness. This study was performed as a basic study to apply the pay factor to the surface roughness for the improvement of pavement quality and performance. The profile data was obtained from the old and new pavements and the analysis was performed to investigate the dynamic loads when vehicles move on the pavements having those profiles. The artificial profiles were also developed to find the effects of the vehicle speed, wavelength and amplitude of the surface roughness on the dynamic vehicle loads. The increase in the load magnitude due to the surface roughness affects the stresses and strains of pavements and finally reduces the pavement life. The methodology to obtain the relationship between the surface roughness and the pavement performance was proposed in this study.

  • PDF

Vibratory Loads Behavior of a Rotor in High Advance Ratios (고속 전진비 조건에서의 로터 진동하중 특성 연구)

  • Na, Deok Hwan;You, Younghyun;Jung, Sung Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.237-243
    • /
    • 2018
  • In this study, the hub vibration load characteristic is evaluated for a rotor in high advance ratio conditions while investigating blade loads through the structural load prediction and harmonic analysis. Numerical studies are performed to validate the wind tunnel test data performed in NASA as the rotor advance ratios are varied from 0.40 to 0.71. A good correlation is obtained for rotor performance calculation at the range of advance ratios considered. It is observed that the hub vibration loads remain almost unchanged when the advance ratios are higher than 0.5, even though the amplitudes of blade structural loads become larger with increasing advance ratios. A harmonic analysis on blade moments is confirmed that the dominant structural mode is 3/rev component for flap bending moments and 4/rev for lag bending moments. The reason is due to the tendency of the second flap and lag mode frequencies which approach 3/rev and 4/rev, respectively, as the advance ratios are increased.

The Fatigue Evaluation of Structural Steel Members under Variable-Amplitude Loading (변동하중을 받는 강구조부재의 피로거동 해석)

  • Chang, Dong Il;Kwak, Jong Hyun;Bak, Yong Gol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.167-175
    • /
    • 1988
  • The principle objective of this study is to evaluate the fatigue behavior of structural steel components of highway bridges subjected to service stresses. The main aspects of this investigation are; 1) a measurement and statistical analysis of service stress cycles observed in highway bridge. 2) fatigue tests under equivalent constant-amplitude(CA) loading and simulated variable-amplitude(VA) loading 3) a evaluation of the fatigue behavior under VA-loading by eqivalent root mean cube (RMC) stress range. Theoretically, the RMC model is adequate in evaluation of fatigue behavior under VA-loading, because the regression coefficient (m) of crack growth rate is 3 approximately. The result of fatigue test shows that the RMC model is fitter than the current RMS model in fatigue evaluation under VA-loading. The interaction effects and sequence effects under VA-loading affect little fatigue life of structural components. As the transition rate of stress ranges is higher, the crack growth rate is higher.

  • PDF

An Experimental Study for the Liquefaction Resistance Strength of Saturated Sand Using Real Earthquake Loading (실지진하중을 이용한 포화사질토의 액상화 저항강도에 관한 실험적 연구)

  • 심재욱;박근보;최재순;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.329-337
    • /
    • 2002
  • Based on the equivalent uniform stress concept presented by Seed and Idriss, sinusoidal cyclic loads which simplified the earthquake loads have been applied in evaluating the liquefaction resistance strength experimentally. However, the liquefaction resistance strength of soil based on the equivalent uniform stress concept can not exactly reflect the dynamic characteristics of the irregular earthquake motion. In this study, the criterion of the liquefaction resistance strength was determined by applying real earthquake loading to the cyclic triaxial test. From the test results, relationships between liquefaction behaviors of saturated sand and earthquake characteristics such as magnitude or time-duration were determined. Magnitude scaling factors to determine the soil liquefaction resistance strength in seismic design were also proposed.

Vibratory Loads Reduction of a Rotor in Slow Descent using Higher Harmonic Control Technology (고조파제어(HHC) 기법을 이용한 저속 하강 비행중인 로터의 진동하중 억제에 관한 연구)

  • You, Younghyun;Jung, Sung Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.440-447
    • /
    • 2013
  • In this paper, a higher harmonic control (HHC) methodology is applied to find the optimum input scenario for the vibratory hub loads reduction. A comprehensive aeroelastic analysis code, CAMRAD II, is used to model the HART (Higher-harmonic-control Aeroacoustic Rotor Test) II rotor, and parametric study is conducted for the best HHC inputs leading to a minimum vibration (MV) condition. The resulting outcomes are compared with the earlier HART II test results. It is indicated that the control input adopted in the MV condition showed less satisfactory results. The new MV condition obtained in the present investigation can achieve 45% lower vibration level than the baseline uncontrolled condition. The optimum HHC input results lead to 3/rev harmonic input having $0.8^{\circ}$ amplitude and $350^{\circ}$ phase angle. About 5% reduction in the required power is possible but accompanies with the increase of vibration level.

과대, 과소응력하에서의 피로크랙발생 전파거동(I)

  • 송삼홍;원시태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.3
    • /
    • pp.301-308
    • /
    • 1985
  • 본 논문에서는 불규칙 하중을 받는 부재에 대한 연구의 고초로서 간단한 응력 모델을 설정하고 이들 변동응력이 가해지는 시기를 명확히 구분하여 크랙전파곡선의 거동을 고찰하였다. 특히 부하되는 응력 진폭의 크기에 따라서 크랙선단부의 미시적 인 변화의 크기가 다르고 이로인하여 크랙전파에 대한 피해의 정도가 달라진다고 하면 크랙전파의 지연 및 가속현상이 나타날 것이 예측이 되고 따라서 이때 나타나는 피해 정도의 크기를 미소 경도치로 환산하여 그것과 피로크랙 전파 특성과를 비교 검토 하 였다.

MICROSCOPIC OBSERVATION OF DRAPED COMPOSTTE MATERIALS : Picture Frame Test (직물 복합재료의 드레이핑 미소 거동 관찰: 사진틀 전단실험)

  • Kang Jae-Hoon;Chang Seung-Hwan
    • Composites Research
    • /
    • v.18 no.2
    • /
    • pp.13-19
    • /
    • 2005
  • In this paper deformation of micro-mechanical parameters such as tow interval, tow thickness and change in tow amplitude are investigated by using dry fabrics (Five-harness satin weave) under shear deformation. To evaluate the observation results according to the generated in-plane forces in the material, bias extension, biaxial test results are compared with. It was found that a picture frame test with a misaligned fibre orientation angle shows large differences in deformation between tensile and compressive tow directions.