• Title/Summary/Keyword: 하중의 기울기

Search Result 106, Processing Time 0.033 seconds

A Case Study of Post-Grouted Drilled Shaft in Weathered Rock (풍화암소켓 대구경 현장타설말뚝의 선단보강그라우팅 사례)

  • Kwon, Oh-Sung;Jung, Sung-Min;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.6
    • /
    • pp.5-16
    • /
    • 2011
  • Post-grouting for the drilled shaft is known to remarkably increase the end bearing capacity of pile by consolidating and reinforcing the disturbed ground containing slime around the pile tip. However, the general design guideline for post-grouting has not been established yet in Korea. Especially in the domestic application, the post-grouting is employed just for repairing the pile with unacceptable resistance rather than for increasing the design resistance of pile. Therefore, little is reported about the effect of post-grouting on the pile resistance itself. In this study, the effect of post-grouting on the resistance of drilled shafts installed in the weathered rock in Korea was estimated by performing the bi-directional load tests on the piles with and without the post-grouting. The test results presented that the initial slope of end bearing-base displacement curve in the pile with post-grouting was 4 times higher than that without post-grouting. At the acceptable settlement (1% of pile diameter), the end bearing capacities of piles with and without the post-grouting were estimated to be 12.0 MPa and 7.0 MPa, respectively, which indicate that the post-grouting could increase the end bearing resistance of pile in weathered rock more than 70%.

Correlation Between the Point-Load Strength and the Uniaxial Compressive Strength of Korean Granites (국내 화강암의 점하중강도와 일축압축강도간의 상관분석)

  • Woo, Ik
    • The Journal of Engineering Geology
    • /
    • v.24 no.1
    • /
    • pp.101-110
    • /
    • 2014
  • This study presents the results of a regression analysis of the point-load strength ($I_{s(50)}$) and the uniaxial compressive strength (UCS) of granites in Korea. The regression was carried out for three cases using the least-squares method, reclassifying the granite samples based on their physical properties. The first regression analysis through the origin according to the weathering grade did not give a result with a sufficient degree of confidence, due to the small number of samples. However, the general trend of the correlation between UCS and $I_{s(50)}$according to weathering grade shows that the slope of the linear regression for weathered granite is steeper than that for fresh granite. The second analysis was a simple linear regression for all the granite samples using the least-squares method as well as a linear regression using the bootstrap resampling method in order to increase the confidence level and the accuracy of the regression results. The third regression considered the average strength of granite groups reclassified according to physical properties. These linear regression analyses yielded linear regression equations with slopes of 14 and small standard deviations being similar to values reported in previous studies on Korean granites, but whose intercept values range from 16 to 43 and have a larger standard deviation than those of the present study. In conclusion, it would be advisable to estimate UCS from $I_{s(50)}$, considering the error range derived from the deviation of the regression equations.

The 33-mode Dielectric and Piezoelectric Properties of PIN-PMN-PT Single Crystal under Stress and Electric Field (압축하중 및 전계 인가에 따른 PIN-PMN-PT 단결정의 33-모드 유전 및 압전특성)

  • Lim, Jae Gwang;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.91-96
    • /
    • 2020
  • The 33-mode dielectric and piezoelectric properties of Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 piezoelectric single crystals were measured under large electric field and compressive stress. The phase transition from the low temperature rhombohedral to the high temperature tetragonal structure was observed in the range of 110~140℃, and the Curie temperature changing to the cubic structure was about 165℃. The polarization change according to the compressive stress and electric field was measured. Relative dielectric constant was calculated from the slope of the polarization curve applied to the electric field, and the calculated relative dielectric constant increased as the applied stress increased, and the relative dielectric constant decreased as the applied electric field increased. The strain according to the compressive stress and electric field change was measured, the piezoelectric constant was calculated from the slope of the curve, and the phase transition according to the application of pressure was confirmed. In the case of practical application as an underwater or medical ultrasonic actuator, it is necessary to properly design the magnitude of the compressive stress applied to the device and the DC bias in order to maintain linear driving.

Evaluation of Fluidity Over Time and Mechanical Properties of Cement-based Composite Materials for 3D Printing (3D 프린팅용 시멘트계 복합재료의 경시변화 및 역학적 특성평가)

  • Seo, Eun-A;Lee, Ho-Jae;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.73-80
    • /
    • 2022
  • This study evaluated changes in fluidity and rheological properties over time for 3D printed composite materials, and evaluated compressive strength and splitting tensile strength properties for laminated and molded specimens. The composite material for 3D printing starts to change rapidly after 30 minutes of extrusion, and the viscosity of the material tends to be maintained up to 90 minutes, but it was confirmed that construction within 60 minutes after mixing is effective. The compressive strength of the laminated test specimen showed equivalent or better performance at all ages compared to the molded test specimen. In the stress-strain curve of the laminated specimen, the initial slope was similar to that of the molded specimen, but the descending slope was on average 1.9 times higher than that of the molded specimen, indicating relatively brittle behavior. The splitting tensile strength of the P-V laminated specimen was about 6% lower than that of the molded specimen. It is judged that this is because the interfacial adhesion force against the vertical load is affected by the pattern direction of the laminated test specimen.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

A Proposal of Stress-Strain Relations Model for Recycled-PET Polymer Concrete under Uniaxial Stress (일축 하중을 받는 PET 재활용 폴리머콘크리트의 응력-변형률 모델의 제안)

  • Jo Byung-Wan;Moon Rin-Gon;Park Seung-Kook
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.767-776
    • /
    • 2004
  • Polymer concrete shows excellent mechanical properties and chemical resistance compared with conventional normal cement concrete. The polymer concrete is drawing a strong interest as high-performance materials in the construction industry. Resins using recycled PET offer the possibility of a lower source cost of materials for making useful polymer concrete products. Also the recycling of PET in polymer concrete would help solve some of the solid waste problems posed by plastics and save energy. The purposed of this paper is to propose the model for the stress-strain relation of recycled-PET polymer concrete at monotonic uniaxial compression and is to investigate for the stress-strain behavior characteristics of recycled-PET polymer concrete with different variables(strength, resin contents, curing conditions, addition of silane and ages). The maximum stress and strain of recycled-PET polymer concrete was found to increase with an increase in resin content, however, it decreased beyond a particular level of resin content. A ascending and descending branch of stress-strain curve represented more sharply at high temperature curing more than normal temperature curing. Addition of silane increases compressive strength and postpeak ductility. In addition, results show that the proposed model accurately predicts the stress-strain relation of recycled-PET polymer concrete

Dynamic Behavior Characteristics of Group Piles with Relative Density in Sandy Soil (건조 모래지반의 상대밀도에 따른 무리말뚝의 동적거동특성)

  • Heungtae Kim;Hongsig Kang;Kusik Jeong;Kwangkuk Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.9
    • /
    • pp.33-40
    • /
    • 2023
  • The lateral load which is applied to the pile foundation supporting the superstructure during an earthquake is divided into the inertia force of the upper structure and the kinematic force of the ground. The inertia force and the kinematic force could cause failure to the pile foundation through different complex mechanisms. So it is necessary to predict and evaluate interaction of the ground-pile-structure properly for the seismic design of the foundation. The interaction is affected by the lateral behavior of the structure, the length of the pile, the boundary conditions of the head, and the relative density of the ground. Confining pressure and ground stiffness change accordingly when the relative density changes, and it results that the coefficient of subgrade reaction varies depending on each system. Horizontal bearing behavior and capacity of the pile foundation vary depending on lateral load condition and relative density of the sandy soil. Therefore, the 1g shaking table tests were conducted to confirm the effect of the relative density of the dried sandy soil to dynamic behavior of the group pile supporting the superstructure. The result shows that, as the relative density increases, maximum acceleration of the superstructure and the pile cap increases and decreases respectively, and the slope of the p-y curve of the pile decreases.

Evaluation of Size Effects of Shallow Foundation Settlement Using Large Scale Plate Load Test (대형 평판재하시험을 이용한 얕은 기초의 침하에 대한 크기효과 평가)

  • Kim, Kyung-Suk;Lee, Sang-Rae;Park, Young-Ho;Kim, Sung-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.7
    • /
    • pp.67-75
    • /
    • 2012
  • This paper addresses the size effect of shallow foundation settlement in very dense weathered granite soil commonly encountered in bridge foundation. Load-settlement curves measured from the plate load tests of 5 different plate sizes in 2 sites were analyzed. The test results showed that the ground beneath the plate was considered not to reach the failure state and the settlement continuously increased proportionately as load increased. The result implies that settlement would govern the stability or serviceability of foundation on very dense weathered soil. The size effect is expressed as a relationship of subgrade reaction modulus to the size of plate. Compared with the previous relationships, the size effect in this result was more prominent and indicated that settlement prediction using the previous method could possibly underestimate the settlement of foundation in dense weathered granite soil.

Stability Evaluation Methods of Agricultural Reservoir by Field Monitoring (현장계측에 의한 농업용저수지 제체의 안정관리기법)

  • Lee, Dal-Won;Oh, Beom-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.30 no.2
    • /
    • pp.164-174
    • /
    • 2003
  • This study was performed to suggest a rational method for the stability evaluation of agricultural reservoir in the very soft ground. The stability methods for agricultural reservoir was used to compare and analyze with various condition by limit equilibrium method. The behavior of settlement-displacement obtained by field monitoring system was used to compare and analyze with various stability methods, and to investigate the applicability of the methods for stability evaluation of agricultural reservoir. The horizontal displacement was abruptly increased when physical properties of soft clay reached its maximum values and therefore, the values of these properties could be used to the fundamental data for stability evaluation. The evaluation of the stability of agricultural reservoir was suggested to use the inclination of curve rather than critical line.

  • PDF

Case Study of Characteristics on Lateral Deformation in Soft Ground under Embankment in the Nakdong River Estuary(I) (낙동강 하구지역 성토하부 연약지반의 측방변형 특성에 관한 사례 연구(I))

  • Han, Byung-Won;Son, Hwa-Soo;Sung, In-Chool;Baek, Young-Gyun;Lee, Gay-Chun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1178-1189
    • /
    • 2010
  • 낙동강 하구지역 연직배수공법이 적용된 연약지반에서 성토시 발생할 수 있는 지반의 측방변형에 대해 3개소 현장 35개 지점에서 수행한 현장 계측데이터를 분석하였다. 성토과정에서 측방변형 패턴 및 변형량을 파악하는데 가장 우선적으로 파악해야 할 계측항목이 지중경사계이며 지반특성별 측방변형 패턴(최대 측방변위발생 지점, 전단변위 발생지점, 지층에 따른 변위발생 형태 등)의 정밀 분석을 위해서는 지중경사계가 설치된 지점의 지층구성을 파악하는 것이 가장 중요하다는 것을 알 수 있었다. 최대 측방변위량과 성토체 중앙부 침하량과의 관계에서는 Tavenas et al.(1979)이 제안한 ${\Delta}_y=(0.18+0.09){\Delta}_s$이하로 관측되었다. 또한 측방변형 억제 및 인접지반의 동반침하를 차단하기 위해 보강된 D.C.M., C.I.P.구간에서는 Tavenas et al.(1979)이 제안한 ${\Delta}_y=(0.18-0.09){\Delta}_s$이하로 관측되었다. 최대 측방변위량과 성토속도와의 관계에서는 과잉간극수압 소산에 필요한 충분한 시간과 원활한 배수가 될 수 있도록 시공관리(성토속도조절, 배수관리 철저)하는 것이 무엇보다도 중요하다는 사실을 다시 한 번 확인 할 수 있었다. 마지막으로 편재하중 재하에 따른 인접 지반 및 구조물의 침하 및 기울기 변화는 측방유동에 의한 거동과 함께 압밀침하에 의한 제체의 체적감소로 인한 인접지반의 동반침하가 상당기간 동안 발생하고 있는 것으로 관측되었다.