Analysis of Cloudiness and Radiation Characteristics during Summer in the Greater Daegu Area (대구지역의 하절기 운량과 장·단파 복사 특성 분석)

  • Baek, Chang-Hyeon;Choi, Dong-Ho;Lee, Bu-Yong;Lee, In-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.13-22
    • /
    • 2017
  • In this study, long and short-wave radiations were observed in urban and suburban areas during the summer season, and frequency analysis was performed for each radiation intensity by a new analysis method. The following results were obtained. (1) Long-wave radiation values were found to be larger in the afternoon than in the morning, in both urban and suburban areas, unlike short-wave radiation values. (2) Short-wave radiation showed a right-skewed frequency distribution. In the high energy area greater than $900W/m^2$, the frequency was significantly higher in the suburbs than in the urban areas. (3) Long-wave radiation was in the range of $290{\sim}479W/m^2$, its frequency distribution resembled a normal distribution, and the frequency of 410, $420W/m^2$ was the highest.

Evaluation of Field Applicability with Coal Mine Drainage Sludge (CMDS) as a Liner: Part I: Physico-Chemical Characteristics of CMDS and a Mixed Liner (차수재로의 광산슬러지 재활용 적용성 평가: Part I: 광산배수슬러지 및 혼합차수재의 물리·화학적 성질)

  • Lee, Jai-Young;Bae, Sun-Young;Woo, Seung-Hyun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.67-72
    • /
    • 2011
  • CMDS (Coal Mine Drainage Sludge) is mainly generated from acid mine drainage during physicochemical treatment or electrical purification. CMDS is well worth considering on recycling possibilities in various areas. This research applies the liner and cover materials using waste disposal landfill generally to treat acid mine drainage sludge. In this Part I of the two parts paper, physico-chemical characteristics of CMDS, bentonite and cement to prepare the liner have been identified using XRD, XRF, FESEM. In addition, combining their physicochemical characteristics, the optimum mixing ratio has been determined to be 1: 0.5: 0.3 for CMDS: bentonite: cement by the batch tests. Initial permeability of CMDS was $7.10{\times}10^{-7}cm/s$. Through the leaching test, it was confirmed that its mixture was environmentally safe. In the Part 2, a large-scale Lysimeter was used to simulate the effects of the layer on the freeze/thaw for evaluation on field applicability and stability.

The Effect of Plant Coverage on the Constructed Wetlands Performance and Development and Management of Macrophyte Communities (식생피도가 인공습지의 질소 및 인 처리효율에 미치는 영향과 습지식물의 조성 및 관리)

  • Ham, Jong-Hwa;Kim, Hyung-Chul;Koo, Won-Seok;Shin, Hyun-Bhum;Yun, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.393-402
    • /
    • 2005
  • The field scale experiment was performed to examine the effect of plant coverage on the constructed wetland performance and recommend the optimum development and management of macrophyte communities. Four sets (each set of 0.88 ha) of wetland (0.8 ha) and pond (0.08 ha) systems were used. Water flowing into the Seokmoon estuarine reservoir from the Dangjin stream was pumped into wetland system. Water depth was maintained at 0.3 ${\sim}$ 0.5 m and hydraulic retention time was managed to about 2 ${\sim}$ 5 days; emergent plants were allowed to grow in the wetlands. After three growing seasons of the construction of wetlands, plant coverage was about 90%, even with no plantation, from bare soil surfaces at the initial stage. During the start up period of constructed wetlands, lower water levels should be maintained to avoid flooding newly plants, if wetland plants are to be started from germinating seeds. Effluent T-N concentration in low plant coverage wetland was higher in winter than high plant coverage wetland, whereas no T-P effluent concentration and removal efficiency difference was observed within 15% plant coverage. Dead vegetation affected nitrogen removal during winter because it is a source of organic carbon which is an essential parameter in denitrification. Biomass harvesting is not a realistic management option for most constructed wetland systems because it could only slightly increase the removal rate and provide a minor nitrogen removal pathway due to lack of organic carbon.

Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment (지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.571-579
    • /
    • 2014
  • A series of field tests on hybrid desiccant cooling systems were conducted in July-August, 2013. The temperature and humidity of the supply and return air, power, and heat consumption were monitored and transferred in real time through the Internet. The performance parameters of the cooling system, namely, cooling capacity and COP (coefficient of performance), were evaluated from the measured data and their variations under outdoor conditions was analyzed. It was found that with increase in the outdoor temperature, the total energy decreases and cooling capacity increases whereas the latter decreases with increase in the outdoor humidity. The COP was also found to increase with the increase in outdoor temperature.

Development of a DEbris flow Loss Estimation Tool using Inventory and GIS (토석류 충격력과 인벤토리를 고려한 GIS 기반 토사재해 피해액 산정 모형 개발)

  • Kim, Byung Sik;Nam, Dong Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.105-105
    • /
    • 2020
  • 전 세계적으로 기후변화에 따른 기온상승 및 강수량 증가, 호우일수 증가 등 이상기후로 인해 다양한 형태의 자연재해가 발생하고 있으며, 이로 인해 우리나라에서도 폭우, 풍랑, 가뭄, 대설 등으로 인한 자연재해 발생이 증가하고 있다. 특히 우리나라는 연평균 강수량 1,300mm의 대부분의 강우가 하절기인 6 ~ 9월에 태풍 및 집중호우를 동반하여 발생하기 때문에 연강수량의 60%이상이 여름철에 집중된다. 이러한 여름철에 집중된 강우로 인해 홍수 및 범람 피해가 여름철에 급증하고 있으며, 2차 피해인 산사태 및 토석류 피해 또한 급증하고 있는 추세이다. 토석류는 집중호우 시 자연산지의 취약한 사면이 붕괴되어 유출수와 함께 급경사의 계류로 붕괴된 토석이 유출되면서 토석류로 전이 및 발전하여 계류하부의 주택 및 농경지를 매몰하여 피해를 발생시킨다. 특히 토석류는 유출수와 함께 토석이 급경사의 계류를 따라 빠른 속도로 이동하고 퇴적 시작점에서 높이의 6배까지 이동하여 인명피해 등 큰 피해를 발생시키는 특성이 있다. 이러한 토석류 피해로 인한 피해와 손실을 최소화하기 위해서는 토석류 발생 시 피해 규모를 예측하여야하며, 또한 하부 구조물의 손실을 정량적으로 해석하여 방재정책의 우선순위를 수립하여야 한다. 따라서 본 논문에서는 강우로 인한 토석류 발생시 하부 구조물의 손실을 정량적으로 해석하기 위하여 토사재해 손실·손상함수를 개발하여, 함수를 탑재한 토사재해 피해액 산정모형인 DELET(DEbris flow Loss Estimation Tool) 모형을 개발하였다. DELET를 이용하여 실제 토석류 피해가 발생한 피해지역에 적용하여 토사재해 피해 구조물의 손실을 평가하였다.

  • PDF

The Trend of Water Quality Variations and Correlation between COD & Chl-a Concentration for the Juam Reservoir (주암호의 수질변화 및 COD 및 Chl-a 농도의 상관관계 분석)

  • Yang, Hyung-Jae;Kim, Byung-Ik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1331-1336
    • /
    • 2006
  • The Juam reservoir, hydrological investigations on the catchment environment and pollutants inflow have been carried out simultaneously. The average COD in 1992 observed in Juam reservoir was 2.3 mg/L, and reached to 2.72 mg/L in 2005 that is increased 0.23 mg/L for 13 years. Following this trend, the water duality is expected to deteriorate down to the second-grade water quality exceeding the 3 mg/L limit in 2010. The concentration exceeding the value of 46.5 $mg/m^3$ will not guarantee the water quality better than $2^{nd}$ grade drinking water resource since correlative between COD and chl-a is y=0.0732x+2.5953 its $r^2=0.8141$. This result will help control the algal growth in the future by taking into account the expected value as a monitoring target.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

Dynamic Change of the DO Concentration by Continuous Monitoring in Artificial Lake (인공 호소의 연속모니터링을 통한 DO 동적변화 규명)

  • Choi, Sunhwa;Lee, Seungheon;Park, Hyungseok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.494-494
    • /
    • 2017
  • 국내의 호소는 대부분이 농업용수 공급을 목적으로 설치된 인공 호소이다. 최근 이상기후 및 유역 오염원 증가로 호소의 수질오염도가 증가 추이에 있으며, 특히 하절기 외기온도 상승과 함께 녹조 대량발생, 어류 집단폐사 등 수질오염사고가 야기되고 있다. 이러한 수질오염사고는 호소의 지역적 특성으로 인한 여러 가지 원인이 있겠지만 직접적인 원인으로는 호소의 산소 고갈에 기인된다. 본 연구에서는 농업용 호소의 수온, DO, EC 등에 대한 일주기 및 계절적 동적변화를 규명하여 호소의 수질개선대책수립에 활용하고자 하였다. 연구대상 지구는 경기도 시흥시에 소재하고 있는 M 농업용 저수지이며, 2015년 6월 4일부터 9월 22일까지 수온, DO, EC을 측정할 수 있는 연속 자동측정장치를 설치하였고, 측정지점은 저수지 수심을 상(바닥층에서 1.5m 상부), 중(바닥층에서 1.0m 상부), 하(바닥층에서 0.5m 상부)로 구분하여 각각 측정하였다. 호소의 수온은 일주기로 수온성층 형성과 대류혼합이 반복되었으며, 상 하층간의 수온 차이가 평균 $1.4^{\circ}C$, 최대 $5.0^{\circ}C$의 차이를 보였다. 또한 강우가 발생한 이후에는 일시적으로 저수지 상 하 층간 수온 차이가 거의 없는 것으로 나타났는데, 이는 강우에 의한 수체의 수직혼합으로 저수지 전체의 물질순환에 영향을 미친 것으로 판단된다. 호내 DO 농도는 일(day) 주기 동안 농도변화가 크게 나타났으며, 여름철 무강우 기간에는 저수지 바닥층의 평균 DO 농도가 약 0.5mg/L로 거의 무산소 상태가 지속되는 것으로 관측되었다. DO는 기온이 낮아지거나 강수가 발생할 때 대류에 의한 수직혼합에 의해 간헐적으로 회복되다가 다시 고갈되는 현상이 반복되는 것으로 나타났다.

  • PDF

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened - (공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.