• Title/Summary/Keyword: 하절기

Search Result 505, Processing Time 0.032 seconds

Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES (구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델)

  • Lee, Seung Jun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.99-120
    • /
    • 2017
  • In SS branch of Korea District Heating Corporation, Combined Heat & Power power plant with 99MW capacity and 98Gcal / h capacity is operated as a district electricity business. In this region, it is difficult to operate the generator due to the problem of surplus heat treatment between June and September due to the economic recession and the decrease in demand, so it is urgent to develop an economical energy new business model. In this study, we will develop an optimized operation model by introducing a renewable energy hybrid system based on actual operation data of this site. In particular, among renewable energy sources, fuel cell (Fuel Cell) power generation which can generate heat and electricity at the same time with limited location constraints, photovoltaic power generation which is representative renewable energy, ESS (Energy Storage System). HOMER (Hybrid Optimization of Multiple Energy Resources) program was used to select the optimal model. As a result of the economic analysis, 99MW CHP combined cycle power generation is the most economical in terms of net present cost (NPC), but 99MW CHP in terms of carbon emission trading and renewable energy certificate And 5MW fuel cells, and 521kW of solar power to supply electricity and heat than the supply of electricity and heat by 99MW CHP cogeneration power, it was shown that it is economically up to 247.5 billion won. we confirmed the results of the improvement of the zone electricity business condition by introducing the fuel cell and the renewable energy hybrid system as the optimization process model.

Analysis of Temperature Influence Experiment on Green Spaces in Campus (캠퍼스 내 녹지공간의 온도분석 및 온도영향요인 규명 실험)

  • Kim, Jaekyoung;Kim, Wonhee;Kim, Eunil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.511-520
    • /
    • 2020
  • Owing to global warming, heat waves have become stronger in the summer, and research on improving the thermal environment of green spaces, such as urban parks, is being conducted. On the other hand, studies on improving the urban thermal environment, which is changing due to the greening pattern and the intensity of the wind, are still insufficient. This study analyzed the temperature of the green spaces on campus to understand the factors affecting the temperature changes. After investigating the covering condition and planting form of the site, factors, such as temperature, humidity, wind direction, wind speed, and illuminance, were measured. The most influential factors on the temperature distribution are evapotranspiration and wind - induced heat transfer. The other major factors affecting the temperature change were the type of cover, wind velocity/wind direction, type of planting, shade / solar irradiance. In the type of cover, the plant was classified as low temperature, and the asphalt pavement was classified as high temperature. In wind speed, instantaneous temperature was reduced by 1.2 ℃ in southern wind, 0.7 ℃ in the westerly wind, 0.4 ℃ in the north wind and 0.5 ℃ in the east wind when a wind of 3.5m/s or more was blown.

Efficacy and phytotoxicity of a petroleum spray oil for control of citrus red mite in Jeju island (제주지역에서 귤응애에 대한 Petroleum Spray Oil의 방제효과 및 식물독성)

  • Kim, Dong-Whan;Kim, Kwang-Sik;Hyun, Jae-Uk;Kang, Si-Yong;Song, Jeong-Hueb;Riu, Key-Zung
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.4
    • /
    • pp.87-92
    • /
    • 2000
  • Recently, a new developed petroleiun spray oil(PSO; D-C Tron $Plus^{(R)}$) has been used to control key pests in integrated pest management (IPM) system of citrus orchards in Australia. The efficacy and phytotoxicity of the PSO against the citrus red mite (Panonychus citri) were compared with conventional pesticides (e.g.Tebufenpyrad, Bifenazate and Sun spray oil) in field condition in Jeju. And under PSO mixing spray with some fungicides, the occurrence of phytotoxic symptoms on citrus leaf was investigated. All concentrations of PSO spraying (0.25%, 0.33%, 0.5% and 1.0%) were significantly suppressed the citrus red mite to similar levels of other conventional pesticides. And the spraying of PSO levels ${\geq}0.5%$ was induced not only occurrence of some oil-sucked symptoms on leaf, but also increase of the dropping leaf and fruit rates. As results from mixing PSO spraying test with other fungicides, little burning on new flush shoot was founded only in PSO 1% plus Fluazinam treatment. From the results of this study, with the consideration of pesticidal efficacy and phytotoxicity, 0.25% and 0.33% PSO spraying level will be recommended for the control of citrus red mite during summer season in Jeju.

  • PDF

Analysis of Physicochemical Characteristics of Suspended Sediments Flowing into the Saemangeum Reservoir in the Summer (하절기 새만금호 유입유사의 물리화학적 특성 분석)

  • Oh, Kyoung-Hee;Chung, Se-Woong;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.99-106
    • /
    • 2015
  • To estimate the effects of suspended sediments flowing into the Saemangeum Reservoir on the extent of contamination of the reservoir, the suspended sediments were collected with sediment traps, which were installed from the upstream of the Mankyung and Dongjin Rivers to estuary of the reservoir, respectively, and the sedimentation rates and the chemical characteristics of suspended sediments were analyzed. The sedimentation rates in the Mankyung and Dongjin Rivers were ranged from 0.01~5.06 and $0.01{\sim}8.75kg/m^2/day$, respectively. Those were higher to the upstream of rivers, and were mainly affected by flood events. The concentrations of organic matters were from 3.3 to 9.6 times higher than those in the stream sediments and were higher after flood season, indicating the contaminants come from the non-point sources on the basin. The concentrations of total nitrogen and total phosphorus in the suspended sediments showed the same trend with the organic matters. These results indicate that the suspended sediments from the basin of the Mankyung and Dongjin Rivers are highly contaminated and the countermeasures to manage the sources of contamination on the basin are required to maintain the water quality of the Saemangeum Reservoir.

Reliability Analysis of EMU Static Inverters considering Influence of Temperature Stress Factor (온도스트레스 영향을 고려한 전동차 보조전원장치의 신뢰성분석)

  • Park, Nam-Chul;Song, Joong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.493-500
    • /
    • 2017
  • Based on the data accumulated through EMU fault management, this paper examines the reliability of old railway car parts and proposes measurements to improve safety. Subway Line 7 of the Seoul Metropolitan Rapid Transit Corporation, auxiliary power unit (Static Inverter) of the EMU second version is a core equipment to supply power to various room-service units in cars and make an effect directly on passenger satisfaction. To analyze the pattern of failure throughout the field data over a long period of time, this analysis of statistics and reliability considers the operating environment and stress factors. This statistical analysis presents the correlation between failure and the temperature stress factors related to frequent failure occurring intensively in summer. In addition, throughout the analysis of the life of the IGBT inverter, the effect of the temperature stress factor was observed before and after the repair. As a result of an analysis of the optimal operating conditions considering two variations of EMU, such as variable load and outside temperature, a difference in the cooling capacity between the optimal operating conditions and frequent failure conditions was observed. Based on this analysis, this paper suggests a way to minimize cooling capacity difference for the optimal operational conditions.

A Study for Controlling Early-age Temperature Rise of the Concrete Pavement by Shadow Tent in Hot Weather Construction (차광막를 이용한 하절기 콘크리트포장의 초기온도 관리 방안연구)

  • Joh, Young-Oh;Kim, Hyung-Bae;Suh, Young-Chan;Ann, Sung-Soon
    • International Journal of Highway Engineering
    • /
    • v.6 no.4 s.22
    • /
    • pp.75-89
    • /
    • 2004
  • Long term performance of concrete pavement significantly depends on the given construction and environmental condition. It means that random cracks and extreme crack width due to inappropriate quality control at the early age might lead to decreasing the pavement service life. The temperature and moisture during the construction, cement and aggregate types, curing condition are major components to affect the quality of the concrete pavement at the early age. First of all, the high temperature differential, that is made by increasing air temperature and the heat of cement hydration, is known as the major contributor to severe cracks. In this study, tent covering was used for controlling temperature of the concrete slab. The field measurement data indicates that the effect of the tent covering is very significant to decrease possibilities of random crack occurrence and curling stress and enhance the long-term concrete strength. HIPERPAV(High PERformance PAVing software), a program predicting the strength and stress of an earty-age concrete pavement (72 hour after placement), is used for simulating the effects of tent covering. The HIPERPAVE results showed that the section with the tent covering has higher reliability than the section without the tent covering by 22.5%. In details, reliability is increased 72.5% (without the tent covering) to 95% (with the tent covering).

  • PDF

Observational Study of Thermal Characteristics by Distribution Ratio of Green Area at Urban in Summer Season (하절기 관측을 통한 도시의 지역별 공간녹지분포율에 따른 열환경 특성 연구)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.8-16
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of thermal environment in the summer season by conducting the field observation of temperature, relative humidity, and globe temperature in some parts of the city. Observation point was divided to a densely populated area, a residential area, a green area, a waterfront green area and a suburban district by the distribution ratio of green area. In this study, the correlation between maximum temperature and globe temperature, study on index for intensity of the tropical night and the temperature distribution characteristic of measurement points by the distribution ratio of green area were analyzed. The results of this study are as follows. (1) The difference between temperature and globe temperature by the distribution ratio of green area is confirmed. The difference of nighttime is more clearly that of daytime. (2) The average temperature and globe temperature of the densely populated area($29.2^{\circ}C$, $33.7^{\circ}C$) are higher than that of the waterfront green area($27.9^{\circ}C$, $32.0^{\circ}C$) by $1.3^{\circ}C$ and $1.7^{\circ}C$, respectively. (3) The number of tropical nights has different days of tropical nights by the distribution ratio of green area of 17days for the Daegu weather station, 14days for adensely populated area, 14days for a residential area, 6days for a green area, 2days for a waterfront green area, and 2days for a suburban district. (4) The results of the slope of trend line for the effects of the temperature on globe temperature change and the intercept for the size of the impact of radiant energy gained around by the analysis of the correlation between the maximum temperature and globe temperature can be utilized objective evaluation index of the each point's artificial effects.

Environmental Impact Assessment of Different Concrete Mixture Proportions according to Domestic Region and Season (국내의 지역 및 계절에 따른 콘크리트 배합별 환경영향평가)

  • Seo, Eun-A;Yang, Keun-Hyeok;Jung, Yeon-Back
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.239-245
    • /
    • 2014
  • This study analyzed a comprehensive database including 6331 ready-mixed concrete plant mixtures to quantitatively assess the environmental impact of concrete under mixture proportions variable according to the domestic region and season. The environmental impact indicator includes global warming, photochemical oxidant creation, abiotic resource depletion, acidification, eutrophication and human toxicity, which are determined from categorization, characterization, normalization and weighting process based on Korea lifecycle inventories. The determined environmental impact indicator was also normalized by concrete compressive strength ($f_{ck}$), which is defined as impact index, to calculate the environmental impact per unit strength of 1 MPa. The most common compressive strength of concrete used in the country is estimated to be 24 MPa and 27 MPa. For $f_{ct}$ of 24 MPa, the lowest environmental impact indicator is observed in Ulsan, whereas the highest region is Gwangju and Daegu. This difference according to domestic region is primarily resulted from by the replacement of different supplementary cementitious materials. Furthermore, the impact index of concrete with $f_{ck}$ of 24 MPa is higher by approximately 5% at wintertime than at summertime and standard season. The impact index gradually decreases with the increase of $f_{ck}$ up to 35 MPa, beyond which it remains constant.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

Application of Different Packaging Methods and Materials for Comparing Freshness of Lettuce (Lactuca sativa L.) harvested in Summer Season (고온기 결구상추의 포장재와 포장방법 적용에 따른 선도 비교)

  • Lee, Jung-Soo;Choi, JeeWon;Kim, Jin Se;Park, Me Hea;Choi, HyunJinn;Lee, YounSuk;Kim, Dong Eok;Hong, YuunPo;Kim, Ji-Gang
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.3
    • /
    • pp.163-171
    • /
    • 2017
  • Effects of different packaging methods for maintaining the shelf life and postharvest quality of iceberg lettuce (Lactuca sativa L.) were studied after harvesting in summer season. Lettuce heads were packaged in plastic crate with or without different films such as (A) Individual lettuce head sealed packaging with linear low density polyethylene (LLDPE) film; (B) Packaging lettuce head in plastic crate and wrapped with LLDPE film; (C): Individual lettuce head sealed packaging with perforated high density polyethylene (HDPE) film; (D) Packaging lettuce head in plastic crate and wrapped with perforated HDPE; and (E) Packaging lettuce head in plastic crate without any film (control), and stored at $2^{\circ}C$ for 35 days. Several quality parameters such as fresh weight loss, SPAD (soil & plant analyzer development) meter value, respiration rate, moisture content and appearance of lettuce were investigated. The lettuce wrapped with individually-sealed LLDPE film showed the lowest weight loss and the highest SPAD value rendering the best appearance index among the treataments throughout the three-week storage period at $2^{\circ}C$. Extending the freshness of iceberg lettuce during low temperature storage will definitely increase the salability potential in the domestic market even during summer season.