Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption using mandibular suction denture with closed mouth technique: a clinical report (치조골 흡수가 심한 완전 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Ko, Chang Woo;Min, Byungkwee;Yang, Hong-so;Lim, Hyun-Pil;Yun, Kwidug;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • When it comes to treat patient with loss of vestibule, conventional denture impression have limitation which can cause problems of excessive border extension. Suction denture with closed mouth technique which was introduced to solve this problem, forms negative pressure being sealed denture flanges by mobile mucosa when the patient swallows and chews. Also, it can decrease patient's visiting time by taking impression and gothic arch tracing at once. In this case, considering patient's chief complain which is a loose fit of present lower denture, suction dentures with closed mouth technique was planned.

Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system (구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례)

  • Jung, Jiwon;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.44-54
    • /
    • 2022
  • Without proper treatment on the multiple tooth missing area, the lack of posterior support and the supra-eruption of the teeth cause many severe complications of occlusion, vertical dimension and masticatory function. This report is a case of full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion due to missing teeth area left untreated for a long time. The patient who is 68-year old male patient had some teeth fallen out while removing his old maxillary denture and was complaining about pain in the region of anterior teeth due to traumatic contact. The vertical dimension was corrected by 4 mm from the top cervical point of the canine through various evaluations and the edentulous area was treated with the implant fixed prostheses through computer guided implant surgery based on the diagnosis and treatment plan for definitive prostheses supported by computed tomography (CT) data analysis and CAD-CAM (Computer-aided design/computer-aided manufacturing) technique. After full mouth rehabilitation, the patient was very satisfied with remarkable improvements in mastication, function, and aesthetics.

Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report (부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • Implant treatment, which was first attempted in fully edentulous patients, is now widely used in partially edentulous, and a single tooth missing patients. Moreover, implant treatment has become an essential treatment modality in modern dentistry. The material of fabricating implant prostheses has also become more diverse than before, one of which is the use of high-performance polymers. The frequency of using high-performance polymers, which have been used in the medical field, is also increased in the dental field compared to the past. In the first case, a PEKK abutment and a PFG crown (cement-screw-retaining type) were fabricated in the lower left second premolar, and in the second case, a PEKK abutment and a monolithic zirconia crown (cement-screw-retaining type) were fabricated in the missing upper left first molar, and in the third case two PEKK abutments and a splinted PFM crowns (cement-screw-retaining type) were fabricated and connected to the upper right first and second molar implants. Through these procedures the patients obtained esthetically and functionally satisfactory results after 4 years of follow-up.

A retrospective statistical analysis of dental implants (치과 임플란트 환자의 통계 분석에 관한 후향적 연구)

  • Zhao, Chun-Ri;Cho, In-Ho;Moon, Eun-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.266-272
    • /
    • 2009
  • Statement of problem: The number of edentulous patients is increasing due to an aging society, which leads to increased demands and interests on implant restorations. Implant restorations are an effective treatment method for both complete and partially edentulous patients, and the success rate has been reported to be high. But because of the increased use of implants in various situations have resulted in frequent reports of failures on implant restorations. Various efforts to overcome these failures have been made. Purpose: The aim of this study was to investigate the statistic survival rate of dental implants on patients who were treated at Dankook University Dental Hospital during the past 10 years based on their charts. Materials and methods :The research was made for two different periods of time; The first investigation was for patients from August, 1998 to August, 2003 and the second was for patients from September, 2003 to April, 2007. Information on the number of implants placed, the location and distribution of implants, the duration between the first and second surgery, and the survival rate of implants were investigated from the patients'charts. Results: 1. According to the first investigation, 1680 implants were placed on 612 patients and the second investigation showed 2438 implants placed on 933 patients. Thus a total of 4118 implants on 1545 patients. 2. Among the 1545 patients, 884 patients were male (57.2 %) and 661 patients were female (42.8%). Out of 4118 implants, 1739 implants (42.2%) were placed on the maxilla, and 2379 implants (57.8%) on the mandible. Implants were placed most frequently in the posterior region of the mandible. A total of 2043 implants (53.2%) were placed in this region. 3. According to the first investigation, 57 out of 1680, implants failed, while from the second investigation, 17 out of 2438 implants were reported as failure. In total, 74 implants failed, which results in a 98.2% survival rate. 4. The average duration between the first and the second surgeries in maxillas decreased from 7.4 months to 6.8 months. The duration also decreased from 5.6 months to 5.0 months in mandibles. Conclusion: As shown in the results, the number of placed implants and the survival rate of implants were higher in the second investigation than that of the first investigation. And the time spent after the first surgery to the second surgery was less in the second investigation. Consequently, it can be presumed that the demand and consumption of dental implants as well as the survival rate will increase in the future.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.

A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants (스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구)

  • Baik, Sang-Hyun;Jang, Ik-Tae;Kim, Sung-Kyun;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.157-168
    • /
    • 2008
  • Statement of problem: Over the past two decades, implant supported fixed prosthesis have been widely used. However, there are few studies conducted systematically and intensively on the splinting effect of implant systems in mandible. Purpose: The purpose of this study was to investigate the changes in stress distributions in the mandibular implants with splinting or non-splinting crowns by performing finite element analysis. Materials and methods: Cortical and cancellous bone were modeled as homogeneous, transversely isotropic, linearly elastic. Perfect bonding was assumed at all interfaces. Implant models were classified as follows. Group 1: $Br{{\aa}}nemark$ length 8.5mm 13mm splinting type Group 2: $Br{{\aa}}nemark$ length 8.5mm 13mm Non-splinting type Group 3: ITI length 8.5mm 13mm splinting type Group 4: ITI length 8.5mm 13mm Non-splinting type An load of 100N was applied vertically and horizontally. Stress levels were calculated using von Mises stresses values. Results: 1. The stress distribution and maximum von Mises stress of two-length implants (8.5mm, 13mm) was similar. 2. The stress of vertical load concentrated on mesial side of implant while the stress of horizontal load was distributed on both side of implant. 3. Stress of internal connection type was spreading through abutment screw but the stress of external connection type was concentrated on cortical bone level. 4. Degree of stress reduction was higher in the external connection type than in the internal connection type.

Retrospective study on survival rate of 2158 osseointegrated implants placed in 770 patients in Sanbon dental hospital of Wonkwang University (원광대학교 산본치과병원에서 770명의 환자에 식립한 2158개의 골유착성 임플란트의 보철 전 초기 생존율에 관한 후향적 연구)

  • Seon, Hwa-Gyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.278-288
    • /
    • 2014
  • Purpose: The aim of the study was to evaluate preprosthetic initial survival rate and factors associated with survival of osseointegrated implants placed in edentulous area of maxilla and mandible and to suspect the possible causes leading to failure. Materials and Methods: A total of 2158 endosseous implants that had been inserted between 2004 through 2013 were placed in 770 patients. The clinical comparisons were performed to evaluate implant loss in relation to age and gender of patients, position, system, length and diameter of implant, and bone graft technique. Results: According to position, the survival rates were 98.23% in maxillary anterior site, 96.98% in maxillary posterior site, 97.85% in mandibular anterior site and 98.76% in mandibular posterior site (P < 0.05). According to diameter of implant, the survival rates were 100% under 3.0 mm, 97.09% between 3.0 to 3.5 mm, 98.19% between 3.5 to 4.0 mm and 98.29% between 4.0 to 4.5 mm but relatively lower survival rate was 75% in 5.0 mm-over (P < 0.05). The survival rates of implants were 89.51%, 98.28%, 98.34% and 99.27% in the group with isolated sinus graft, with isolated GBR, with sinus graft and GBR simultaneously and without bone graft, especially (P < 0.05). Conclusion: This study establishes a relationship between survival rate of implant and position, diameter of implant system and bone graft technique. In conclusion, there were low survival rates in maxillary posterior site, in dental implants with wide diameter of 5 mm-over, and in the group with isolated sinus graft.

The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures (하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포)

  • Sung, Chai-Ryun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.375-390
    • /
    • 2009
  • Statement of problem: Implant supported overdenture is accepted widely as a way to restore edentulous ridge providing better retention and support of dentures. Various types of attachment for overdenture have been developed. Purpose: The purpose of this study was to investigate the influence of attachment type in implant overdentures on the biomechanical stress distribution in the surrounding bone, prosthesis and interface between implant and bone. Material and methods: Finite element analysis method was used. Average CT image of mandibular body(Digital $Korea^{(R)}$, KISTI, Korea) was used to produce a mandibular model. Overdentures were placed instead of mandibular teeth and 2mm of mucosa was inserted between the overdenture and mandible. Two implants($USII^{(R)}$, Osstem, Korea) were placed at both cuspid area and 4 types of overdenture were fabricated ; ball and socket, Locator, magnet and bar type. Load was applied on the from second premolar to second molar tooth area. 6 times of finite element analyses were performed according to the direction of the force $90^{\circ}$, $45^{\circ}$, $0^{\circ}$ and unilateral or bilateral force applied. The stress at interface between implants and bone, and prosthesis and the bone around implants ware compared using von Mises stress. The results were explained with color coded graphs based on the equivalent stress to distinguish the force distribution pattern and the site of maximum stress concentration. Results: Unilateral loading showed that connection area between implant fixture and bar generated maximum stress in bar type overdentures. Bar type produced 100 Mpa which means the most among 4 types of attachments. Bilateral loading, however, showed that bar type was more stable than other implants(magnet, ball and socket). 26 Mpa of bar type was about a half of other types on overdenture under $90^{\circ}$ bilateral loading. Conclusions: In any directions of stress, bar type was proved to be the most vulnerable type in both implants and overdentures. Interface stress did not show any significant difference in stress distribution pattern.

Mandibular implant supported overdentures with two different mini-implant systems: A case report (두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례)

  • Park, Jin-Hong;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.267-272
    • /
    • 2016
  • This case report describes the treatment of two fully edentulous patients with mini-implant overdentures using different implant systems on narrow mandibular alveolar bone ridge. They were complaining about discomfort and pain wearing mandibular conventional complete dentures caused by insufficient retention. Each patient received four miniimplants in the interforaminal area of the mandible using the non-submerged flapless surgical approach. One-body type implant (Slimline, Dentium, Seoul, Korea) was used for a patient and loaded immediately after surgery. Metal housings of O-ring were attached by direct technique. For the other patient, two-piece type implant (LODI, Zest Anchors, Escondido, CA, USA) was used and impressions were made for attachment connection of the Locator's metal housings after 8 weeks of surgery. Within this case report, mandibular miniimplant overdentures using different implant systems showed improvement of patient satisfaction with favorable peri-implant tissue response 6 months after attachment connection. However, long-term follow-up is needed for further evaluation.