• Title/Summary/Keyword: 하수처리시스템

Search Result 271, Processing Time 0.03 seconds

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method (이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발)

  • Choi, Soo-Jung;Kim, Ye-Jin;Yoom, Hoon-Sik;Cha, Jae-Hwan;Choi, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • Diagnosis on setteability based on human operator's experimental knowledge, which could be established by long term operation, is a limit factor to construction of automation control system in wastewater treatment plant. On-line SVI(Sludge Volume Index) analyzer was developed which can measure SV30 automatically by image capture and image analysis method. In this paper, information got by settling process was studied using On-line SVI analyzer for better operation & management of WWTPs. First, SV30 detection algorithm was developed using image capture and image analysis for settling test and it showed that automatic detection is feasible even if deflocculation and bulking was occurred. Second, turbidity assessment model was developed using image analysis.

The study on introduction of the canal way for Sustainable Development (지속가능한 개발을 위한 주운시설 도입에 관한 연구 (인천 청라지구를 중심으로))

  • Jeon, Jei-Bok;Kwon, Myeong-Sin;Kim, Ji-Ho;Oh, Kyu-Chang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1462-1466
    • /
    • 2008
  • 본 연구에서는 청라지구 경제자유구역 개발사업의 일환으로 지구내 하천 및 공원에 최적의 주운시설을 도입하기 위한 방안을 모색하였다. 유역의 일반현황 및 국내외 사례조사를 통해 현재까지 진행된 주운관련 사례를 분석하여 적용가능성을 검토하였으며 이수, 치수, 환경 측면에서 주운시설 도입을 위한 종합적인 검토를 수행하였다. 물수지분석, 담수량 및 손실량 파악, 물갈이율 조사 등을 통해 필요수량을 파악하였으며, 산정된 필요수량 확보를 위해 하수처리장 고도처리수, 상수원수, 상수도, 유역관리 등의 다각도의 수량확보 방안을 검토하여 적용가능방안을 제시하였다. 또한 하천수질현황, 국내외 수질기준, 생태계 친수환경에 미치는 영향을 고려하여 목표수질을 설정하였으며, 유역, 하천, 호수공원 및 내부수로 등에 적용가능한 수질보전방안을 제시하였다. 인근하천, 중앙호수 공원, 내부수로를 동시에 고려하여 유역통합관리 차원의 치수안전성 확보 방안을 제시하였으며 주운시설 도입에 따른 추가적인 치수안전성 확보방안을 검토하였다. 특히 간척지라는 지역적 특수성을 고려하여 항구적인 치수 및 이수 대책의 필요성을 제시하였으며, 지속 가능한 개발을 위해 최첨단 유지관리 시스템의 도입 및 안전시설 확보를 통해 재해로 부터 안전한 주운계획을 제시하였다. 향후 청라지구-서해-굴포천 방수로-한강을 잇는 해상과 연계된 주운 개발을 통한 광역운하망 구축 방안을 제고하였다. 향후 주운시설의 도입에 따라 도시의 어매니티 증진과 친수도시 구현, 물순환 확보와 치수에 안전한 방재도시 수립이 가능할 것으로 판단되며 이를 통해 지속가능한 신도시 개발의 초석이 될 수 있을 것으로 사료된다.

  • PDF

Advanced Wastewater Treatment Using Biofilter System with Floating Media under Alternative Flow (유로변경식 부상여재 생물여과시스템을 이용한 하수고도처리)

  • Ryu, Hong-Duck;Lee, Jeong-Hun;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.250-257
    • /
    • 2006
  • The objective of this study is to propose an alternative process for the small sewage treatment plants in rural communities. A biofilter has been used for biological wastewater treatment, which is becoming the alternative to the conventional activated sludge system. The proposed process used in this study, which is packed with floating media (i.e. expanded polystylene), has advantages of biofilter system and alternative flow system and they are incorporated into one process. Pilot and bench scale studies were performed using domestic wastewater. In the results of pilot plant study, it was observed that the stable effluent water quality was achieved and it met the present effluent criteria of suspended solid (SS), organic matters, T-N and T-P. In the study for determination of the cycle of backwashing, it was observed that the cycle of backwashing depended on BOD loading rates of influents. In the BOD loading rates of $0.5kg\;BOD/m^3{\cdot}day$ and $1.0kg\;BOD/m^3{\cdot}day$, the backwashing cycle of 28 hour and 16 hour were needed, respectively. The optimum backwashing time was 120~80 seconds at the media expansion rate of 50%. In the removal of SS, organic matters, T-N and T-P, SS removal was rather achieved by physical filtration than biological mechanism and the removal of organic matters except for SS, T-N and T-P were mainly rather achieved by biological mechanism than physical filtration. In bench-scale study, the effects of recirculation rate was investigated on removal of SS, TCOD, T-N and T-P. It was observed that the recirculation made removal efficiencies of SS, TCOD, T-N and T-P increased. Especially, in T-N removal, the increase of T-N removal efficiency of 40% was observed in the reicirculation rate of 1Q compared with 0Q.

Simulations of a System Dynamics Model for Operations and Maintenance of Activated-Sludge Wastewater Treatment Plants (활성슬러지 하수처리시설 운영 및 유지관리를 위한 시스템다이내믹스 모델의 모의에 관한 연구)

  • Park, Suwan;Kim, Bong Jae;Jun, Hwan Don;Kim, In Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.905-912
    • /
    • 2006
  • In this paper, simulation methods of the system dynamics model developed by Das et al. (1997) for activated-sludge wastewater treatment plants are illustrated in an attempt to determine the operating rules and the policies related to capacity expansion of an activated-sludge wastewater treatment plant. For existing conditions, the analyses were performed by varying activated-sludge return rate to observe changes in effluent water quality and treatment efficiency. The effluent water quality is also analyzed for various average daily inflow conditions and activated-sludge return rates. As a result, without expanding the aeration tank, maximum average daily inflow that can satisfy the effluent water quality standard of BOD $0.02kg/m^3$ was determined as $2,840m^3/hr$, subject to 100% of activated-sludge return rate while other factors remain constant. When the activated-sludge return rate is less than 100%, expansion of the aeration tank is necessary and minimum sizes of the aeration tank to satisfy the effluent water quality standard were determined for various activated-sludge return rates. In addition, the total operating and maintenance as well as unit treatment cost regression equations for activated-sludge wastewater treatment plants are suggested by using the cost data that are obtained from Water and Wastewater Division, Ministry of Environment. The regression analyses showed that the economies of scale phenomena exist in the operating and maintenance costs of activated-sludge wastewater treatment plants.

The Evaluation of Temperature Effect on Nitrogen RemovaI at Intermittent MBR System by Computer Simulation (컴퓨터 시뮬레이션을 이용한 간헐폭기 MBR공정에서의 운전온도 변화에 따른 질소제거 성능 평가)

  • Lee, Byonghi;Park, Min-Jung
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.489-501
    • /
    • 2012
  • The nitrogen removal characteristics of the MBR system consisted of two intermittent reactors, a membrane reactor and a deaeration reactor under constant flow and wastewater composition at different operational temperature and SRTs (Sludge Retention Times) were studied by computer simulation. The nitrogen removal efficiencies were dropped from 59% to 31%, when operational temperature was increased to $25^{\circ}C$ from $13^{\circ}C$ with same SRT of 25 days. Lower RBO (Readily Biodegradable Organic) concentrations at intermittent reactors at $25^{\circ}C$ compared with those at $13^{\circ}C$ of operational temperature were believed to be the main cause. The nitrogen removal efficiencies and RBO concentrations at each intermittent reactors were recovered when SRT was reduced to 12.6 days at $25^{\circ}C$. The effect of both SRT and operational temperature on RBO concentrations at intermittent reactors is need to be studied further.

A study on the vaneless diffuser and volute casing design for the improvement of small centrifugal compressors (소형 원심 압축기의 성능 향상을 위한 베인 없는 디퓨저와 볼류트 케이싱의 설계에 관한 연구)

  • Jo, Jae Phil;Paek, Seung Yun;Kim, Sung Don;Ahn, Kyubok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3722-3730
    • /
    • 2015
  • The performance improvement of a small centrifugal compressor for waste water treatment has been conducted by the design change of vaneless diffuser and volute casing. Existing two compressors use a common impeller, but the width and length of the vaneless diffuser and the cross-sectional shape of the volute casing are different, respectively. Based on the experiment of the existing two compressors and their CFD results, the design of the vaneless diffuser and the volute casing has been changed. It was found that the strength of the interaction among the volute tongues, the vaneless diffusers and the impellers of two existing/one improved compressors, was affected by the cross-sectional area and inlet radial length of the volute casing including system losses' change. The efficiency of the impeller with one existing design was increased as the decrease of the width of the vaneless diffuser, but losses at the diffuser were accumulated. In conclusion, approximately 2.88%p efficiency increase at the design point of the new compressor with the improved design has been confirmed by CFD analysis results.

Parameter Optimization Analysis in Urban Flood Simulation by Applying 1D-2D Coupled Hydraulic Model (도시침수 최적화 모의를 위한 1D-2D 모형의 연계해석)

  • Kim, Beom Jin;Ha, Chang Yong;Kim, Byung-hyun;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.48-48
    • /
    • 2017
  • 도시지역에서는 이상강우, 돌발홍수와 더불어 급속한 도시화에 따라 침수 발생의 위험성이 증가하고 있다. 지자체에서는 빗물펌프장, 지하저류조 등을 이용하여 적극적으로 침수대책을 강구하고 있지만, 저지대 침수피해는 계속적으로 발생하고 있다. 2013년 7월 서울 경기북부 강원영서에 발생한 집중호우로 1명이 사망하고 피해액은 94,036백만원이 발생하였다. 춘천시 효자동 저지대지역의 주택침수는 인근 하천의 수위가 높아져 내수배제 및 하수도 처리 능력이 부족하여 침수가 발생하였다. 2014년 8월 경남지역에 발생한 집중호우로 2명 사망하였고, 피해액은 134,158백만원에 이르렀으며, 도시화 토지피복변화로 인한 홍수량이 증가하여 피해가 가중되었다. 이에 따라 도시 내 정확한 도시유출 및 침수해석을 통하여 과거 침수양상을 재현하고 앞으로 발생할 수 있는 침수피해를 방지할 수 있도록 침수 예 경보 시스템을 개발하여 도시침수에 대비하고 도시주민들의 인명과 재산피해를 경감하는데 그 목적이 있다. 이를 위해 도시지역의 관망해석에 적합한 모형을 선택하여야 하며, 그 모형의 매개변수를 결정하여야 한다. 도시유출해석 및 관망해석을 위하여 SWMM 모형을 선정해서 유역분할조건, 매개변수에 대한 최적 검정과정을 제시하여, 1D-2D 연계모형을 통해서 침수지역예측의 정확도를 증대시키고자 한다. 본 연구에서는 서울시 강남역 주변 일대의 5개 배수분구을 대상으로 도시유출해석을 위한 최적화 모의를 위하여 1D-2D모형의 연계해석하였다. 실제 강우사상을 적용하여 매개변수와 소유역 개수를 달리하여 자동최적화기법인 PEST를 이용하여 최적인자를 도출하여, 실제 배수맨홀의 수위관측 자료를 이용하여 비교 보정을 하였다. 도시유출해석뿐만 아니라 내수침수시의 최적인자 도출을 위해 2차원 범람해석을 통하여 NDMS 자료를 이용하여 비교 보정을 한 뒤 다른 강우사상을 이용하여 검증을 하여 도시침수 해석의 정확도를 개선을 위한 최적인자들을 검토하였다.

  • PDF

Habitat characteristics of exotic fish in Korean reservoirs (농업용 저수지 내 외래어종의 분포특성)

  • Son, Minwoo;Byun, Jisun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.512-512
    • /
    • 2016
  • 우리나라의 다양한 수계에서는 배스로 대표되는 외래어종의 유입에 따른 심각한 생태계 교란이 발생하고 있다. 외래어종은 활발한 먹이활동 및 영역다툼을 통해 우리나라 고유종의 섭취 및 경쟁 우위에 위치하고 있다는 것이 많은 보도를 통해 발표되었다. 본 연구에서는 외래어종 중 배스(Large mouth bass)에 초점을 두고 동계 및 춘계의 서식처 특성을 살펴본다. 다양한 수계 중 갇혀있는 시스템으로 간주할 수 있는 농업용 저수지에 초점을 맞추고 현장조사를 실시한다. 하지만 현장조사 중 일부는 강과 같이 열린 서식처 공간도 포함하고 있다. 본 연구는 배스가 동면을 하지 않는 대신 수온에 큰 영향을 받으며 저수온기의 서식활동을 지속한다는 가정 하에 수온과 배스가 활동하는 영역의 상관성을 이해하고자 하였다. 조사는 국내 4개 지점 이상에서 이루어졌으며 수심 20 m 정도의 깊은 저수지에서부터 하수종말처리장에서 처리수가 유입되는 도시형 하천까지 포함한다. 이 중 수심 20 m 정도의 농업용 저수지에서는 7회 이상의 정밀 조사를 수행하여 수심별, 수온별 배스의 서식특성을 이해할 수 있도록 집중조사를 실시하였다. 현장조사 결과 배스는 $1-2^{\circ}C$의 수온차에도 민감하게 반응하며 서식처를 형성한다는 사실을 알 수 있다. 수온의 평면적 분포는 서식처의 형성에 많은 영향을 주는 것으로 판단되며 수온 안정기인 동계의 경우는 수온 종분포에 따라 군락을 형성하며 서식층을 결정한다는 점도 유추된다. 4월 중순 이후의 춘계는 배스의 산란기로 종확산에 큰 영향을 미치는 가장 중요한 시기이다. 이 시기 이후 하계에는 다시 부화한 개체가 독립적으로 서식처를 이동하는 또다른 종확산의 시기이다. 따라서 계절별에 따른 보다 면밀하고 지속적인 조사를 통해 4계절 순환에 따른 배스의 서식 특성 변화를 조사하는 과정이 필수적으로 이루어져야 한다.

  • PDF

The application of multifunctional metal oxide for wastewater treatment: Adsorption and disinfection (다기능 금속산화물의 하수처리 적용-흡착 및 살균)

  • Kim, Heegon;Park, Duckshin;An, Byungryul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.251-258
    • /
    • 2019
  • The physical treatment such as chemical precipitation or adsorption was usually added after biological treatment in wastewater treatment process since it was enforced to reduce the concentration of phosphate for wastewater effluent to 0.2 mg/L as P which was well known as one of main nutrient causing eutrophication in waterbody. Therefore, the new material functioned for both adsorption and disinfection was prepared with Fe and Cu, and $TiO_2$, respectively, by changing the ratio of concentration referred to tri-metal (TM). According to SEM-EDS, $TiO_2$ was 30~40% composition for any TM regardless of any synthesis condition. However, the ratio of composition for Fe and Cu was dependent on the initial Fe and Cu concentration, respectively. The removal efficiency of phosphate was obtained to 15% at low initial concentration and the maximum uptake (Q) was calculated to ~11 mg/g through Langmuir isotherm model using TM1 which was synthesized at 1000 mg/L, 1000 mg/L, and 2 g (10 g/L) for $Fe(NO_3)_3$, $Cu(NO_3)_2$, $TiO_2$, respectively. In disinfection test, the efficiency of virus removal using TM was increased with increase of dosage of TM and can be reached 98% at 0.2 g.