• Title/Summary/Keyword: 하수처리방류수

Search Result 185, Processing Time 0.026 seconds

Status of a national monitoring program for environmental radioactivity and investigation of artificial radionuclide concentrations (134Cs, 137Cs, 131I) in rivers and lakes (방사성물질 측정망 현황 및 하천·호소 내 인공방사성물질 (134Cs, 137Cs, 131I) 조사)

  • Kim, Jiyu;Jung, Hyun-ji;An, Mijeong;Hong, Jung-Ki;Kang, Taegu;Kang, Tae-Woo;Cho, Yoon-Hae;Han, Yeong-Un;Seol, Bitna;Kim, Wansuk;Kim, Kyunghyun
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.377-384
    • /
    • 2015
  • A survey of the artificial radionuclides in rivers and lakes was conducted to investigate their levels in surface water. Water samples were collected at 60 points and analyzed by gamma-ray spectrometry with a measurement time of 10,000 seconds for 134Cs, 137Cs, and 131I. The obained values were lower than MDA for all points, except one point for 131I that was 0.533±0.058 Bq/L. 131I is known as a radioactive material that occurs frequently in sewage treatment plants. Because it is often used for medical treatments and subject to spreading into the environment due to the excretion from the patients. For the point where 131I was detected, we conducted additional investigation on the upstream river point and the effluent points of nearby sewage treatment plant to find the source of 131I. 131I was not detected at the upstream points of one of the upstream sewage treatment plants but found at the downstream points with the level being 0.257±0.034 to 0.799±0.051 Bq/L, proving the sewage treatment plant was the 131Isource.

A Study on Clogging and Water Quality Improvement in Floodplain Filtration with Flood/rest Raw-water Supply (범람/휴지식 홍수터여과에서 폐색현상 및 수질개선도 연구)

  • Kim, Hoh-Seok;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.120-131
    • /
    • 2011
  • A pilot-scale experiment of floodplain filtration with a filtration depth of 3.6m was performed employing flood/rest type raw-water supply system in an effort to find ways to improve river water quality by additional treatments of discharged effluent from sewage treatment plant. Soil samples were taken from 3 sites including Gumi, Daegu and Gimhae along the Nakdong river. Reductions of infiltration rates following increases in operating time was investigated in each soil sample, along with the analysis of removal efficiencies of various pollutants according to different depths and infiltration rates. The results show incremental development of clogging on the soil surface with increases in operation time, and illustrate exponential decrease in the infiltration rate. The time required for the removal of the clog from the soil surface was longer than 2 weeks for all soil samples analyzed. The stable infiltration rates for soils were 5 m/day for Gumi and for Daegu and Gimhae was 1 m/day. In unsaturated soils dissolved oxygen levels increased following the increase of filtration depth, suggesting that alternating application of flood and rest for raw-water supply effectively keeps the soil environment aerobic. For all soils, the nature of pollutant removal depending on the depth of filtration remained the same regardless of the infiltration rate. Most of the BOD and turbidity were removed within 1.2 m, about 30% of COD was removed within 3.6m and was expected to be removed further with increases in filtration depth. Nitrification occurred near the surface of all soils; however there was no significant removal of nitrogen in the filtration depths tested in this study. Although removal rate of phosphorus was low for Gumi's soil, it was high enough for other soils, suggesting that the method developed in this study could significantly improve river water quality.

Factors Affecting the Formation of Iodo-Trihalomethanes during Chlorination in Drinking Water Treatment (정수처리에서 염소 처리시 요오드계 트리할로메탄류 생성에 영향을 미치는 인자들)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Kim, Kyung-A;Song, Mi-Jeong;Choi, Jin-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.542-548
    • /
    • 2014
  • Effects of bromide ($Br^-$) and iodide ($I^-$) concentrations, chlorine ($Cl_2$) doses, pH, temperature, ammonia nitrogen concentrations, reaction times and water characteristics on formation of iodinated trihalomethanes (I-THMs) during oxidation of iodide containing water with chlorine were investigated in this study. Results showed that the yields of I-THMs increased with the high bromide and iodide level during chlorination. The elevated pH significantly increased the yields of I-THMs during chlorination. The formation of I-THMs was higher at $20^{\circ}C$ than $4^{\circ}C$, $10^{\circ}C$ and $30^{\circ}C$. In chloramination study, addition of ammonium chloride ($NH_4Cl$) markedly increased the formation of I-THMs. Among the water samples collected from seven water sources including wastewater treatment plant (WWTP) effluent water (EfOM water), prepared humic containing water (HA water) and algal organic matter (AOM) containing water (AOM water), EfOM water generated the highest yields of I-THMs ($12.31{\mu}g/mg$ DOC), followed by HA water ($4.96{\mu}g/mg$ DOC), while AOM water produced the lowest yields of I-THMs ($0.99{\mu}g/mg$ DOC). $SUVA_{254}$ values of EfOM water, HA water and AOM water were $1.38L/mg{\cdot}m$, $4.96L/mg{\cdot}m$ and $0.97L/mg{\cdot}m$, respectively. The I-THMs yields had a low correlation with $SUVA_{254}$ values ($r^2$ = 0.002).

Method of Reducing Separation Membrane Fouling Using Microbubbles (마이크로버블을 이용한 분리막 파울링 저감방법)

  • Kyung-Hwan Ku;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • Due to water shortages caused by water pollution and climate change, total organic carbon (TOC) standards have been implemented for wastewater discharged from public sewage treatment facilities. Furthermore, there is a growing interest and body of research pertaining to the reuse of sewage treatment water as a secure alternative water resource. The membrane bio-reactor (MBR) method is commonly used for advanced wastewater treatment because it can remove organic and inorganic ions and it does not require or emit any chemicals. However, the MBR process uses a separation membrane (MF), which requires frequent film cleaning due to fouling caused by a high concentration of mixed liquor suspended solid (MLSS). In this study, process improvement and microbubble cleaning efficiency were evaluated to improve the differential pressure, water flow, and MF fouling, which are the biggest disadvantages of operating the MF. The existing MBR method was improved by installing a precipitation tank between the air tank and the MBR tank in which raw water was introduced. Microbubbles were injected into a separation membrane tank into which the supernatant water from the precipitation tank was introduced. The microbubble generator was operated with a 15 day on, 15 day off cycle for 5 months to collect discharged water samples (4L) and measure TOC. As the supernatant water from the precipitation tank flowed into the separation membrane tank, about 95% of the supernatant water MLSS was removed so the MF fouling from biological contamination was prevented. Due to the application of microbubbles to supernatant water from the precipitation tank, the differential pressure of the separation membrane tank decreased by 1.6 to 2.3 times and the water flow increased by 1.4 times. Applying microbubbles increased the TOC removal rate by more than 58%. This study showed that separately operating the air tank and the separation membrane tank can reduce fouling, and suggested that applying additional microbubbles could improve the differential pressure, water flow, and fouling to provide a more efficient advanced treatment method.

Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe (갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가)

  • Jeong, Gwanjo;Son, Boyoung;Lee, Inja;Ahn, Chihwa;Kim, Junil;Moon, Boram;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.371-376
    • /
    • 2016
  • In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.

Evaluation of Basic Unit for Non-point Pollutants in Runoff of West Coast Highway - Maesong Area (서해안 고속도로 매송지역 비점오염원 원단위 산정 연구)

  • Park, Seyong;Mo, Kyung;Kim, Leehyung;Kang, Heeman;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.33-40
    • /
    • 2010
  • In this study, evaluation of basic unit of non-point pollutant, which is fundamental evaluation of non-point loading, was conducted using both road point and angle of intersection point in Maesong area, West coast highway by utilizing Event Mean Concentrations(EMC). Concentration of pollutants except heavy metals at these two points rapidly decreased in 30 minutes after start of runoff. According to the results of EMC, for both sampling points, it was determined that the concentrations of TSS(Total Suspended Solid), $BOD_5$(Biological Oxygen Demand), and DOC(Dissolved Organic Carbon) were higher than those of wastewater effluent standard in Korea, however, the concentrations of T-N(Total Nitrogen) and T-P(Total Phosphorus) were lower than those of the standard. In terms of heavy metals, Fe, Pb, and Zn showed higher concentrations than others. When compared with the units established by the Ministry of Environment in Korea, the basic units of $BOD_5$ and T-N in this study were lower. On the other hand, when compared with foreign units, Cu, Pb, and Zn showed approximately 10 times higher concentrations. It was estimated that a long term monitoring should be conducted for obtaining additional data and more reliable basic units for the non-point pollutnats based on the results from this study.

A Plot Scale Experiment to Assess the NPS Reduction for Non-irrigated Cropland (밭 비점오염 저감효과 평가를 위한 포장실험 연구)

  • Park, Tae-Yang;Kim, Sung-Jae;Jang, Jeong-Ryeol;Choi, Kang-Won;Kim, Sang-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.313-313
    • /
    • 2011
  • 오염물질은 배출원의 형태에 따라 점오염물질과 비점오염물질로 구분하고 있고 점오염물질은 생활하수, 산업폐수, 축산폐수, 환경기초시설 방류수 등으로 발생원이 명확하고 수집하여 처리 및 관리가 용이하나 비점오염물질은 배출위치가 명확하지 않으며, 강우 시 일시적으로 대량 배출되는 특징을 가진 농경지, 도로, 대지, 임야 등에서 배출되는 오염물질을 말한다. 우리나라에서 비점오염은 전체 수질오염의 42~67%(2003년)를 차지하는 것으로 나타났고, 2015년에는 전체 수질오염의 65~75%에 이를 것으로 예상되고 있다. 이 중 농업 비점오염원은 총 수질 오염량의 30%이상을 차지할 것으로 추정하고 있으나 이를 저감하기 위한 최적관리방법의 효과검증에 관한 연구는 아직 미미한 상태이다. 이에 본 연구에서는 농경지 중 밭에서 발생하는 비점오염을 저감하기 위한 기법으로 다양한 규모와 형태의 Silt Fence/식생밭두렁/침사구를 설치하여 밭 비점오염에 대한 저감효과를 평가하고 제어대책을 개발하여 최적관리기법을 제시하고 이에 대한 매뉴얼을 개발하기 위한 기초연구를 실시하려 한다. Silt Fence는 주로 건설공사현장에서 홍수유출 발생 시 인접한 하천 및 호소 등으로 유사 및 오염물질이 유입되는 것을 방지하기 위해 임시적으로 설치하는 시설로 합성 직물 필터를 나무나 금속 막대로 연결하여 등고선 방향으로 설치하는 것으로 대상 지역의 토양이 교란되기 전에 그 지역 아래쪽에 설치한다. 식생밭두렁은 밭의 이랑의 길이가 길어질수록 강우 시 빗물이 하단에 이를 때 늘어난 유량과 빠른 유속으로 토양침식이 가중되는데, 이때 30~35m간격으로 식생밭두렁을 설치하게 되면 상부와 하부의 침식정도가 유사한 경향을 보여 식생밭두렁을 설치하지 않은 지역에 비해 토양의 침식정도가 작게 나타나게 된다. 이러한 Silt Fence/식생밭두렁/침사구의 밭 비점오염의 저감효과 평가 및 제어대책 개발을 위한 기초 실험을 수행하기 위해 경상남도 사천시 용현면 선진리 일대에 시험포장을 조성 하였으며, 시험포장내에 6개의 Plot을 만들어 하단부에 포장에서의 유출수의 유량을 측정하기 위해 플룸을 설치하였고 실내실험을 통해 플룸의 수위-유량관계 곡선을 작성하였다. 포장의 토양특성을 판별하기 위해 Plot별로 토양시료를 채취하여 특성을 분석 한 결과 6개 Plot모두 모래함량이 많은 점토질 사질토로 분류되었다. 향후 강우 시 시험포장에서 발생하는 유출수의 수질을 분석하고 Silt Fence/식생밭두렁/침사구의 오염물질 저감효과를 분석하여 제어대책을 개발하게 되면 농업수자원확보를 위한 관리방안 선정을 위한 정책수립에 활용될 수 있으며 비점오염 배출을 최소화시켜 수질의 개선에 기여할 뿐만 아니라 우리나라 농업에 적합한 최적영농관리기술을 개발 할 수 있을 것으로 사료된다.

  • PDF

Development of weekly rainfall-runoff model for drought outlooks (가뭄전망을 위한 주간 강우-유출 모형의 개발 및 적용)

  • Kang, Shinuk;Chun, Gunil;Nam, Woosung;Park, Jinhyeog
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.214-214
    • /
    • 2019
  • 가뭄이 '심함' 단계 이상 도달 시에는 매주 수문분석을 수행하여 가뭄전망을 수행하여야 한다. 이를 위해서는 기상청의 강수량과 기온 등의 기상예측 자료가 필요하다. 현재 기상청에서는 3개월 기상전망으로 월단위 강수량과 평균기온을 매월 제공하고 있다. 1개월 전망에서 4주의 강수량합과 평균기온을 제공하고 있다. 하지만, 향후 4주간을 전망하는 1개월 전망에서는 1주단위의 강수량과 평균기온이 아닌, 4주간의 강수량합과 평균기온을 1주일 단위로 업데이트해 WINS에 제공하고 있다. 1주단위의 강수량과 평균기온을 취득하기 어려워, 평년 일단위 강수량과 평균기온 자료를 사용하여 4주간의 자료를 1주 단위로 분할하는 방법을 사용하였다. 주간단위 수문자료의 처리를 위해 국제표준기구(ISO)에서 제시하는 기준(ISO 8601)에 따랐다. ISO 8601은 월요일부터 일요일까지를 1주로 정의하며 현재 사용하고 있는 날짜체계와 1대1로 대응되도록 하였다. 예를 들면 1981년 2월 22일은 '1981-W07-7' 또는 '1981W077'로 표시한다. 표시된 형식은 1981년 7번째 주 일요일을 뜻한다. 이 기준에 따라 수문자료를 정리할 수 있도록 프로그램을 개발하였다. 주간 단위 잠재증발산량 계산은 월잠재증발산량 프로그램을 1주단위로 계산할 수 있도록 수정 및 보완하여 개발하였다. 수정 및 보완한 부분은 외기복사(外氣輻射)량 계산부분이다. 외기복사량은 지구가 태양을 1년 주기로 공전하므로 특정 위도에서 특정날짜에 따라 복사량이 달라지므로 주간단위의 월요일부터 일요일에 해당하는 날짜의 외기복사량을 각각 계산하고 이를 평균하여 주간단위 대푯값으로 사용하도록 하였다. 계산된 주간단위 외기복사량과 최고 최저기온을 입력하여 Hargreaves식에 의해 잠재증발산량을 계산한다. 융적설을 포함한 주단위 강우-유출 모형의 매개변수를 추정하기 위해 전국 24개 지점의 수문자료를 사용하였다. abcd 모형과 융적설모듈의 초기값 포함 11개 매개변수를 SCE-UA 전역최적화 알고리즘으로 추정하였다. 추정된 유역의 매개변수는 토양배수, 토양심도, 수문지질, 유역특성인자를 사용한 군집분석 결과에 의해 113개 중권역에 할당하였다. 개발된 주간단위 강우-유출 모형은 비교적 단기 가뭄전망을 위해 사용된다. 계산된 유량은 자연유량이며, 전국 취수장 수량, 하수처리장 방류수, 회귀수를 반영하여 지점별 유량을 계산하여 가뭄전망에 사용되고 있다.

  • PDF

A Study on Grade Classification for Improvement of Water Quality and Water Quality Characteristics in the Han River Watershed Tributaries (한강 수계 지류 하천의 수질 특성 및 수질 개선을 위한 등급화 방안 연구)

  • Cho, Yong-Chul;Park, Minji;Shin, Kyungyong;Choi, Hyeon-Mi;Kim, Sanghun;Yu, Soonju
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.215-230
    • /
    • 2019
  • The objective of this research is to evaluate the water quality characteristics using the statistical analysis of major tributaries in the Han River and to provide water quality improvement plan by selecting tributaries that should be preferentially managed by river grade classification method. The major 15 tributaries in Han River watershed were monitored for discharge and water quality during January-December 2017. As a result of the correlation analysis, the river discharge has been not correlation with other water quality constituents (p>0.05) but COD and TOC were significantly correlated (r=0.957, p<0.01). The main cause of water quality fluctuation was organic pollutants and nutrients in the principal component analysis (PCA) method. The BOD, COD, TOC, TN, and TP were found to be significantly different (p<0.05) by seasonal in result of one-way ANOVA analysis. Result of river grade classification by quantitative indicators the tributaries requiring improvement of water quality were Gulpocheon, Anyangcheon, Wangsukcheon, and Tancheon which affected by wastewater treatment plant.In this research, we determined tributaries that need to improve the water quality of Han River watershed and it can be used as an important data for efficient water quality management.

High-Rate Phosphorous Removal by PAC (Poly Aluminum Chloride) Coagulation of A2O Effluent (생물공정 처리수의 PAC (Poly Aluminum Chloride) 응집에 의한 고효율 인 제거 특성)

  • Hwang, Eung-Ju;Cheon, Hyo-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.673-678
    • /
    • 2009
  • High-rate phosphorous removal by PAC (poly aluminum chloride) coagulation of A2O effluent was investigate to meet the stringent requirement of wastewater discharge from municipal wastewater treatment plant. A series of jar tests were conducted to find optimum coagulation condition and to enhance removal efficiency. The optimum volumetric concentration of PAC was 30 ppm (2.81mol Al/mol P by mol ratio). Only 17.2% of soluble P was removed for 30 minutes' settling without PAC addition, while this increased to 30.3% by dosing 10ppm PAC. It even increased conspicuously from 49.3% to 88.4% by increasing PAC dose from 20 ppm to 30 ppm. 92.4% of total P was removed by 30 ppm PAC, and the effluent concentration (0.3 mg/L) was acceptable for discharge. The optimum value of coagulation time, settling time, and pH were 4minutes, 20 minutes, and 7.0, respectively. It was not necessary to control pH of raw sample whose pH was 7.0. Soluble P removal was remarkably enhanced at pH 7.0. This implied that sweep floc formation by $Al(OH)_3$ was the main mechanism of coagulation for soluble P removal. Influent and effluent of secondary clarifier were tested for coagulation, and the effluent was better for high-rate P removal. It resulted in 0.18 mg/L of P and 95.4% of P removal by coagulation. It was favorable to recycle the treated water to coagulation tank and the optimum recycle ratio was 0.3.