• Title/Summary/Keyword: 하수시설

Search Result 597, Processing Time 0.025 seconds

The Effective Maintenance of Sewage Treatment Plant with Development of Database Management Library (자료관리(資料管理) Library의 개발(開發)을 통한 하수처리장(下水處理場)의 효율적(效率的)인 유지관리(維持管理))

  • Lee, Jae-Kee;Lee, Hyun-Jik;Choi, Suk-Kun;Park, Kyung-Yeol;Lho, Byeong-Cheol
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.5 no.1 s.9
    • /
    • pp.103-118
    • /
    • 1997
  • In recent years, there have been emerging the establishment and extension of sewage treatment facilities in many cities due to population growth and high standard for sewage treatment. The objective of this study is to develop and implement a Data Management Library which could deal with enormous amount of graphic and attribute data effectively and afficiently. Based on the Data Management Library developed, the Sewage Treatment Management System(STMS) was Implemented and investigated in preparation for the extension of sewage treatment facilities. Cheongju city enviromental station was selected as a test site. We first analyzed current work flow in sewage treatment and then performed database design suitable for managing sewage treatment in effective fashion. The STMS consists mainly of two parts : one is for manipulating the graphic and attribute data and the other for application of sewage treatment related works. Conclusively, the STMS developed in this study could be utilized as a comer stone for an effective maintenance and management of sewage treatment.

  • PDF

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

Characteristics of Water Quality Change of Urban River according to Installation of Interceptors and Wastewater Treatment Plant (차집관로와 하수처리시설의 설치에 따른 도시하천의 수질변화 특성)

  • Zhou, Juan Juan;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.813-820
    • /
    • 2014
  • In this study, the characteristics of water quality change of the three streams in Daejeon were analyzed according to the expanded installation of interceptors and wastewater treatment plant (WTP). Gabcheon 5 (Singu Bridge) location showed the maximum difference of the highest and lowest concentrations in the last decade. However, the recent water quality of this location was worse than other locations, because of the impact of the effluent from the WTP. In the upstream of the WTP, the Daejeon stream was relatively better than the other locations in organic pollution reduction, and this was caused by the investment for the management of the interceptors in three streams of Daejeon. According to the water quality standard of the stream water quality, the recent water quality of the three streams in Daejeon was acceptable within them in the most of the water quality items, but because the total phosphorus concentration of the upstream such as Daejeon stream, Yudeng stream, Gabchen 3 location did not reach the standard values, a better management of the interceptor was required in the upstream of WTP than its downstream. The upstream of WTP also required a better management of the interceptor than the downstream. The operation and management of WTP was required a high efficiency because the water quality of the effluent from the WTP incurred an adverse effect to the target water quality in the location of the total water pollution load management system.

The Study on the Estimation of Emission from Sewage Treatment Plant and Manure Treatment Plant (하수 및 분뇨처리시설에서 악취물질 배출량 산정에 관한 연구)

  • 전의찬;사재환;김기현;이성호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.87-88
    • /
    • 2003
  • 최근 민원의 약 20%를 차지하며, 대기질 관리 대상 중의 하나인 악취는 호흡기장애, 순환기장애, 소화기능장애, 수면장애 둥을 유발시켜는 등 인체에 다양한 악영향을 미치고 있으며, 다양한 성분이 극히 낮은 농도로 존재할 경우에도 인간의 감각기관을 가즉하게 된다. 또한, 쓰레기매립시설, 소각시설, 하수처리시설, 분뇨처리시설, 음식물쓰레기처리시설 등의 환경기초시설과 기타 생활악취 배출원들은 주로 주민의 생활주변에 밀접하게 연관되어 있는 시설이다. (중략)

  • PDF

A Study on the Performance Development of Sewage Concrete by Application of Antibiotics (항균제 도포에 의한 하수시설 콘크리트의 성능향상에 관한 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Khil, Bae-Su;Cho, Bong-Suk;Lee, Eui-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.371-378
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties of concrete covered with antibiotics were investigated. As a results of the study, it was proved that the antimicrobial performance of antibiotics was available. Also compressive strength and bond strength of concrete didn't closely connected with antibiotics, and resistance to abrasion, water absorption, air permeability, carbonation, salt damage and chemical attack of concrete was improved remarkably by covering with it.

A Study on Pre-treatment Facility for Foodwaste and Sewage Sludge Mixture (음식폐기물과 하수슬러지 병합처리를 위한 전처리시설에 관한 연구)

  • Kim, Jong-Oh;Lee, Chang-Ho;Kim, Ji-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.1
    • /
    • pp.84-89
    • /
    • 2003
  • The purpose of this study was to evaluate and improve the pre-treatment facility for foodwaste and sewage sludge mixture treatment. The process of foodwaste pre-treatment consists of storage, classification with crushing, and thickening. The effluent of sewage treatment facility was used as the diluting and washing water. The panicle size of foodwaste after pre-treatment was almost under 2mm, the mixture of foodwastes and sewage sludge showed an advantage to the anaerobic digestion. The amount of gas production increased from 0.8ton/day ($CH_4$ : 0.5ton/day) to 3.5ton/day ($CH_4$ : 2.3ton/day) after the anaerobic digestion of the foodwastes and sewage sludge mixture. The amount of sludge cake increased from 11.2ton/day to 21.2ton/day. Therefore, the proper operation of the foodwaste pre-treatment facility was contributed to the efficient anaerobic digestion of foodwaste and sewage sludge mixture treatment.

  • PDF

A Study on the Analysis of the Urban Sewer Volume Using the Expert System (전문가기법을 이용한 도시 하수용량 분석에 관한 연구)

  • 이규석;유재용
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.11 no.1
    • /
    • pp.67-75
    • /
    • 1993
  • The urban expansion and the modernization of the urban infrastructure need a new technology to manage the facilities. The sewer management, one of the urban infrastructures, requires geographical information systems(GIS) for this purpose, and can be supported by the expert system. Consequently, non-professionals can use this system conveniently. In this study, the search and retrieving capacity of the relational database management system(DBMS) and the chain topology generator of the vector-based GIS were integrated into the sewer management system together with the expert knowledge. This system can predict the sewer volume charge by the simulation, and automate these procedures. This system is also user-friendly by using the user-interface. Finally, the system was applied to one of the Seoul drainage districts and tested.

  • PDF

Development of Gutter Storage System for Urban Inundation Reduction (도시침수 저감을 위한 측구 저류시스템의 개발)

  • Lee, Sung Ho;Kim, Jung Soo;Lee, Jae Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.330-330
    • /
    • 2020
  • 국지성 호우의 증가로 인해 설계빈도 이상의 강우가 빈번하게 발생함에 따라 도시 지역의 내수침수피해가 빈번하게 발생하고 있다. 국지성 호우의 영향으로 특히 하천변 및 저지대의 유출량이 증가함에 따라 기존 하수관거의 통수능 부족으로 침수피해가 증가하고 있는 실정이다. 따라서 내수침수피해 저감을 위한 다양한 노력들이 이루어지고 있으나 도시지역의 경우 노후화 된 하수관거 교체를 위한 예산이 부족하며 도시개발이 완료됨에 따라 지하저류조 등의 저류지설을 설치하기 위한 부지 확보가 어려운 실정이다. 도시 지역에서 강우의 유출은 대부분 하수관거 시설에 의해 처리되므로 하수관거 통수능 부족 시 침수피해가 발생하게 된다. 따라서 기존 하수관거와 연계할 수 있으며 설치 부지와 큰 예산이 소요되지 않는 새로운 유형의 유출저감시설을 적용할 필요가 있다. 따라서 본 연구에서는 기존의 도로 배수시설에서 도로 표면 유출수의 수로역할을 하던 측구부를 도시지역의 상습침수 지역 및 개발지역 등 국지성 호우로 인한 내수침수 저감이 가능하며 기존 홍수방어시설에 비해 대규모의 부지와 예산이 소요되지 않는 새로운 우수저류시설을 개발하여 상습침수 지역에 개발된 저류시스템을 적용하여 측구 저류시스템의 용량에 따른 저류능력 및 내수침수 저감효과를 검토하고자 한다.

  • PDF

A Study on the Management System Improvement of Effluent Water Qualities for Public Sewage Treatment Facilities in Korea (우리나라 공공하수처리시설의 방류수 수질 관리체계 개선방안 고찰 - 미국, 일본, 유럽의 공공하수처리시설 방류수 수질 관리제도를 중심으로 -)

  • Jeong, Donghwan;Choi, Incheol;Cho, Yangseok;Chung, Hyenmi;Kwon, Ohsang;Yu, Soonju;Yeom, Icktae;Son, Daehee
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.4
    • /
    • pp.296-314
    • /
    • 2014
  • In recent years, Ministry of Environment (MOE) has been implementing a phased strengthening of the effluent standards for sewage treatment plants. In this regard, a comprehensive system should be developed to help check the appropriateness of such standards by specifying the grounds for standard-setting and investigating the current operation of sewage treatment plants clearly. It is necessary to establish a new standard-setting system for the effluent that is in a closer connection with the environmental criteria and rating systems. In the United States, the federal government provides guidelines on the least provisions and requirements for the Publicly Owned Treatment Works (POTWs). Local governments set the same or stricter guidelines that reflect the characteristics of each state. In Japan, the sewage treatment plants are subject to both the effluent standards and the discharge acceptable limits to pubic waters under the sewerage law. Specific requirements and limits are set in accordance with local government regulations. The European Union imposes sewage treatment plants with different provisions for effluent standards, depending on the sensitivity of public waters to eutrophication. The effluent standards for sewage treatment plants are classified by pollutant loads discharged to receiving waters. MOE also needs to introduce systems for setting new parameter standards on a POTW effluent by applying statistical means and treatment efficiencies or optimal treatment techniques, as seen in the cases of the US National Pollutant Discharge Elimination System (NPDES) or the EU Integrated Pollution Prevention and Control (IPPC).

The Impact of a Basic Environmental Facility Siting on Land Prices : A Case of Sewage Disposal Plant (환경기초시설의 입지가 지가에 미치는 영향 : 하수처리장을 사례로)

  • JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.170-180
    • /
    • 2017
  • This research analyzed the effect of a basic environmental facility siting on the difference in land prices using a case study of Jisan sewage disposal plant in Daegu metropolitan city. To do so, two buffer zones were generated around Jisan sewage disposal plant to 400m at an interval of 200m as a setback distance and 822 officially announced individual land prices were acquired from Korea Ministry of Land, Infrastructure and Transport(MOLIT). Paired samples t-test was performed to compare the mean difference in land prices before and after Jisan sewage disposal plant siting. Results show that the mean land price from each buffer zone was slightly increased after the siting and the difference was statistically significant. Also, the results indicate that the mean land price within 200m was lower than that between 200m and 400m before the siting while there was not different in the mean land price for both buffer zones after the siting. Because Jisan sewage disposal plant did not have a stench and a larger capacity and its surrounding areas were blended by commercial and residential uses, a sewage disposal plant siting had little effect on the fall in land prices unlike previous studies. The findings from this research will provide new reference data for local government and local people with conflicting views on the siting of a basic environmental facility.