• Title/Summary/Keyword: 하수도 시설

Search Result 641, Processing Time 0.032 seconds

A Study on Long-term Variations of BOD and COD as Indicators of Organic Matter Pollution in the Han River (한강 본류에서 유기물 오염도 지표인 BOD와 COD에 대한 장기변동 특성)

  • Cho, Hyun-Seok;Kim, Kwang-Rae;Lim, Gyu-Chul;Bae, Kyung-Seok;Lee, Min-Hwan
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.4
    • /
    • pp.474-481
    • /
    • 2012
  • This study was performed to investigate the degree of long-term pollution at the mainstream of the Han River by comparing the concentration of BOD and COD from 1975 to 2011. The long-term annual average BOD and COD concentration at the mainstream of the Han River showed an increasing trend as it flowed downstream from Paldang Dam to Gayang. The concentration of BOD ($r^2$=0.646) and COD ($r^2$=0.260) showed a consistent decreasing trend for 37 years. In the case of Paldang Dam, BOD has maintained a decreasing trend, whereas the COD value showed an increasing trend after the 1990s. Therefore, a control of non-biodegradable materials in areas around Paldang Dam is required. The result of the seasonal variations of BOD and COD is as follows: spring>winter>summer and fall (p<0.001). The time series analysis revealed a strong correlation for every 12-month period. Also, the amount of water discharge at Paldang Dam has to be systematically controlled because the amount of water discharge from the dam influences the water quality at the mainstream of the Han River.

An Epidemiological Investigation on an Outbreak of Shigellosis in a Special School for Handicapped in Yeongcheon-si and in a Rehabilitation Facility in Gyeongsan-si, Korea, 2008 (2008년 영천시 지적장애인 학교와 경산시 재활원에서 발생한 세균성이질에 관한 역학조사)

  • Lee, Hyun-Dong;Lee, Soon-Ok;Lim, Hyun-Sul
    • Journal of agricultural medicine and community health
    • /
    • v.34 no.1
    • /
    • pp.24-33
    • /
    • 2009
  • Objectives: In September 2008, an outbreak of diarrhea occurred among students attending Y school in Yeongcheon-si. Shigella sonnei was cultured from some of the rectal swabs. An epidemiological investigation was carried out to determine the source of the infection and the mode of transmission of the shigellosis outbreak. Methods: The index case lived in the D rehabilitation facility in Gyeongsan-si and an additional epidemiological investigation was carried out there. The cases could not be questioned due to their mental handicaps. The teachers were interviewed instead. A patient case was defined as a resident with diarrhea more than one time a day from September 18 to September 26, 2008 or a resident with confirmed Shigella sonnei at the Y school or the D rehabilitation facility. Results: The attack rate was 1.2% (8 persons) among 659 persons in the Y school and D rehabilitation facility. Five persons were microbiologically confirmed to have the infection and three persons were diagnosed on the basis of symptoms. Shigella sonnei was cultured from five of the 659 rectal swabs. However, 80 environmental specimens including drinking water, preserved foods, and cooking utensils were negative. All eight patients were Y school students and had been living in group boarding and lodging. Six of them lived in the D rehabilitation facility and two lived in the dormitory at the Y school. Five cases showed pulsed-field gel electrophoresis patterns that were identical for Shigella sonnei. Conclusions: The results of this study showed that the infection source of the shigellosis outbreak, in the two places, were identical. It is likely that the infections initially spread from a teacher or volunteer and then among the students.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

End-use analysis of household water by metering (가정용수의 용도별 사용량 조사 및 원단위 분석)

  • Kim, Hwa-Soo;Lee, Doo-Jin;Kim, Ju-Whan;Kim, Jung-Hyun;Jung, Kwan-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.869-877
    • /
    • 2008
  • The purpose of this study is to investigate the trends and patterns of variou kind of water uses in a household by metering in Korea. Water use components are classified by toilet, washbowl, bathing, laundry, kitchen, etc. Flow meters are installed in 146 household selected by sampling in all around Korea. The data are gathered by web-based data collection system from the year 2002 to 2006, considering pre-investigated data such as occupation, revenue, family members, housing types, age, floor area, water saving devices, education, etc. Reliable data are selected by upper fence method for each observed water use component and statistical characteristics are estimated for each residential type to determine liter per capita per day. Estimated domestic per capita day show an indoor water use with the range from $150{\ell}pcd$ to $169{\ell}pcd$ for each housing type as the order of high rise apartment, multi-house, and single house. As the order of consuming amount among water use components, it is investigated that toilet($38.5{\ell}pcd$) is the first, and the second is laundry water($30.8{\ell}pcd$), the third is kitchen($28.4{\ell}pcd$), the fourth is bathtub($24.7{\ell}pcd$), the next is washbowl($15.4{\ell}pcd$). The results are compared with water uses in U.K. and U.S. As life style has been changed into western style, pattern of water use in Korea is tend to be similar with the U.S. water use pattern. Compared with the surveying results by Bradley, on 1985. Thirty liter of total use increased with the advancement of economic level, and a little change of water use pattern can be found. Especially, toilet water take almost half part of total water use and laundry water shows lowest as 11% in surveying at the year of 1985. But, this study shows that 39 liter, 28% of toilet water, has been decreased by the spread of saving devices and campaign. It is supposed that the spread large sized laundry machine make by-hand laundry has been decreased and water use increased. Unit water amount of each end-use in household can be applied to design factor for water and wastewater facilities, and it play a role as information in establishing water demand forecasting and conservation policy.

  • PDF

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF

Removal of Organic Matter and Nitrogen from River Water in a Model System of Floodplain Filtration (홍수터 여과 모형을 이용한 하천수중의 유기물과 질소 제거)

  • Ha, Hyun-Soo;Kim, Sang-Tae;Kim, Seung-Hyun;Jeong, Byeong-Ryong;Lee, Young-Deuk;Eum, Jin-Sup;Ji, Seung-Hwan;Chung, Jong-Bae
    • Applied Biological Chemistry
    • /
    • v.45 no.2
    • /
    • pp.84-91
    • /
    • 2002
  • If contaminated river water is sprayed over the floodplain, organic matter and nitrogen would be removed by microbial processes in the rhizosphere of vegetation during the filtration through soil. In this study we tested the organic matter and nitrogen removal from contaminated river water by the floodplain filtration. Model system of floodplain was constructed using a PVC pipe (15 cm i.d. ${\times}$ 150 cm L) which was packed with a loamy sand soil collected from a floodplain in Nakdong river. The model system was instrumented with soil solution samplers and gas samplers. A river water collected from Omogcheon in Kyongsan was sprayed from top of the model system at three different rates. The concentration of organic matter, DO, $NO_3^-$, $NO_2^-$, $NH_4^+$, $N_2$ and $N_2O$, and redox potential were measured as a function of soil depth for 24 days after the system reached a steady state. When river water was sprayed at the rates of 40.8 and 68.0 $l/m^2/day$, a significant reductive condition for denitrification was developed at below 5-cm depth of the soil. When the water reached at 90-cm depth of the soil, COD and concentration of inorganic nitrogen were lowered, on an average, from 18.7 to 5 mg/l and from 2.7 to 0.4 mg/l, respectively. $N_2$ comprised most of the N gas evolved from denitrification and $N_2O$ concentrations emitted at the surface of soil were less than 1 {\mu}l/l. The effective removal of organic matter and nitrogen by the filtration in the model system of floodplain demonstrates that the native floodplains, which include rhizosphere of vegetation at the top soil, could be more effective in the treatment of contaminated river waters and other industrial waste waters containing high concentration of organic matter and nitrogen.

A Study on the Evaluation Criteria for Reconstruction Charge Allocation (재건축부담금 배분을 위한 지자체 평가기준 연구)

  • Kim, Joo-Jin;Song, Young-Hyun
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.35-46
    • /
    • 2011
  • This paper aims at examining the indices and their weights for the evaluation of local government to allocate reconstruction charge and reviewing the availability of them simulating local governments' evaluation. There has been no specific evaluation criteria existed, while central government has to allocate the reconstruction charge to local governments by the provision 3 of Restitution of Housing Reconstruction Gains Act. The results as follows : According to a survey on evaluation indices weight and AHP analysis, the weight of 'the housing welfare improve effort' is the highest with 25.1% among 5 upper-classification indices. Following this, each weight of 'housing welfare conditions(22.7%)', 'housing SOC establishment(22.5%)', 'the achievement and planning on reconstruction charge use(15.8%)', and 'housing sector achievement such as Bogeumjari(13.9%)' are ranked. Meanwhile, Among 16 lower-classification indices, 'the rate of minimum housing standard households(11.5%)', 'public rental housing supply(8.9%)', 'reconstruction charge use achievement(8.3%)', 'reconstruction charge use planning submit(7.5%)', and 'rate of water and sewage(6.3%)' hold high rank. The analysis results show the weight of 'housing sector achievement such as Bogeumjari' on the existing provisions should be decreased(30%${\rightarrow}$13.9%) as others' weight has to be slightly increased. According to the result of the simulation, Jeonbuk, Gyeongbuk, Jeonnam, Jeju, Gyeonggi received higher scores in the comprehensive evaluation, while Daejeon, Seoul, Incheon, Daegu and Gwangju, where the housing conditions are relatively good, received lower scores. These results of the analysis correspond with the direction of reconstruction charges allocation and indicate that the evaluation criteria used in this simulation is acceptable.

A Study on Management of Seafood Wastewater Treatment Facility using Submerged MBR (침지식 MBR을 이용한 수산물 폐수처리장 운영에 관한 연구)

  • Choi, Yong-Bum;Lee, Hae-Seung;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7227-7236
    • /
    • 2015
  • The survey revealed that, due to the discharge characteristics of seafood wastewater, irregular inflow loads were caused, making it difficult to treat the wastewater safely. It is crucial for the operation of pressure and floating tanks for the treatment of high-concentration organic wastewater such as seafood wastewater. The survey of operation factors for the pressure and floating tanks revealed this: A/S ratio 0.05 (design criteria 0.01), the pressurized air pressure 8bar(design criteria 6bar), the pressure tank pressure 6bar (design criteria 4.5bar), and HRT 60sec(design criteria: 10sec). Also, the recirculation rate was changed to over 40%(design criteria: 30%), and the surface load rate was changed to under $13.7m^3/m^2{\cdot}hr$(design criteria: under $17.7m^3/m^2{\cdot}hr$); thus, compared to the initial design criteria, the operation factors were changed according to inflow characteristics, thus enhancing the pressure and floating tank performance. The survey of inflow load revealed BOD 140.7%, $COD_{Mn}$ 120.32%, and SS 106.3%, compared to the inflow design criteria, as well as T-N 135.5% and T-P173.3%, higher than the design criteria. The survey of the treatment facility annual operation cost revealed high portions in sludge treatment cost(27.7%) and chemicals costs(26.0%), and the sludge treatment cost will likely further increase due to the ban on ocean dumping. The unit cost for the treatment of seafood wastewater was found to be KRW 3,858 per ton, more than 27 times higher than the sewage treatment cost(KRW 142.6/ton), presumably because the seafood wastewater contains high-concentration organic substances and nutritive salts.

Survey on a Disposal Method of Contact Lenses after Use (콘택트렌즈 사용 후 폐기처분에 대한 실태 조사)

  • Park, Il-nam;Kwon, Min-sun;Park, Ji-woong;Lee, Ki-Seok;Jung, Mi-A;Lee, Hae-Jung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.553-560
    • /
    • 2018
  • Purpose : To investigate a disposal method of disposing contact lenses and the recognition of environmental pollution by micro plastics which may be caused by the wrong disposal method of domestic contact lens wearers. Methods : Two hundred sixty one adults(124 males, 137 females, mean age $21.48{\pm}3.14years$) were participated in this study. They were given the questionnaire survey on contact lenses purchasing place, type of contact lenses, duration of wearing contact lenses, the disposal method of disposing contact lenses and the recognition of the occurrence of environmental pollution. Results : It appeared that eyeglass shop(50.0%) and contact lens shop(48.3%) were the main purchasing places, and the most common type of contact lenses were disposable lenses(38.5%) and daily wearing lenses(52.5%). On the duration of wearing contact lenses they answered more than 5 years(29.3%), less than 1 year (26.0%), less than 1 year to less than 3 years (26.0%), and on wearing a contact lens during a week they did 1-2 days (32.0%), 1 week (28.0%), 5-6 days (22.4%) and 3-4 days (17.6%). It was shown "no(78.3%)" and "yes(21.7%)" to the questionnaire of whether they received information or education about a disposal method at the place where the contact lens was purchased, and "no(87.5%)" and "yes(12.5%)" to the questionnaire of whether they received information or education from schools, public institutions or public media such as the internet. As for the disposal methods, landfill waste(45.6%), recycled garbage(29.6%), and drainage(16.8%) from the sink or toilet responded in order. Although men were more educated and informed about disposal than women (t=3.63189, p<0.00001), women were more aware of environmental pollution(t=2.44269, p=0.01605). Conclusion : In order to reduce the environmental pollution issue caused by the contact lens which does not decompose at the sewage treatment facility and become micro plastics, it is urgent to provide information about correct disposal methods after using contact lenses and to educate contact lens wearers.

Assessment of Contamination and Sources Identification of Heavy Metals in Stream Water and Sediments around Industrial Complex (산업단지 유역 하천수와 퇴적물 내 중금속 오염도 평가 및 기원 추적 연구)

  • Jeong, Hyeryeong;Lee, Jihyun;Choi, Jin-Young;Kim, Kyung-Tae;Kim, Eun-Soo;Ra, Kongtae
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.3
    • /
    • pp.179-191
    • /
    • 2019
  • Heavy metals in stream water and sediments around industrial complex were studied in order to assess the contamination and to identify the potential source of metals. High variability has been observed for both dissolved and particulate phases in stream water with coefficient of variation (CV) ranging from 1.3 to 2.8. The highest metal concentrations in both phases were observed in Gunja for Ni and Cu, in Jungwang for Zn and Pb and in Shiheung for Cd, respectively. These results indicate that the different metal sources could be existing. The concentrations of the heavy metals in sediments decreased in the order of Cu>Zn>Pb>Cr>Ni>As>Cd>Hg, with mean of 2,549, 1,742, 808, 539, 163, 17.1, 5.8, $0.07mg\;kg^{-1}$, respectively. Mean of metal concentrations(except for As) in sediments showed the highest values at Shiheung stream comparing with other streams. In sediments, the percent exceedance of class II grade that metal may potentially harmful impact on benthic organism for Cr, Ni, Cu, Zn, Cd, Pb was about 57%, 62%, 84%, 60%, 68%, 81% for all stream sediments, respectively. Sediments were classified as heavily to extremely polluted for Cu and Cd, heavily polluted for Zn and Pb, based on the calculation of Igeo value. About 59% and 35% of sediments were in the categories of "poor" and "very poor" pollution status for heavy metals. Given the high metal concentrations, industrial wastes and effluents, having high concentrations of most metals originated from the manufacture and use of metal products in this region, might be discharged into the stream through sewer outlet. The streams receive significant amounts of industrial waste from the industrial facilities which is characterized by light industrial complexes of approximately 17,000 facilities. Thus, the transport of metal loads through streams is an important pathway for metal pollution in Shihwa Lake.