• Title/Summary/Keyword: 하수도 시설

Search Result 642, Processing Time 0.033 seconds

Relationship Between Environmental Infra Operating Cost and Polluter Pay Principles (환경기초시설 운영비 보조와 오염원인자부담원칙)

  • Kang, Heechan;Kang, Sung Won;Kim, Minjoon
    • Environmental and Resource Economics Review
    • /
    • v.24 no.1
    • /
    • pp.165-187
    • /
    • 2015
  • In this paper, we tested if the sewage subsidy from Korean Water Management Fund discourage sewage fee increase by Korean local governments, and consequently hinder water quality improvement. To examine this counter-incentive effect of Water manage Fund sewage subsidy, we estimated the effect of sewage subsidy on the ratio of sewage fee revenue to environmental treatment facilities' operation cost of local governments in 2009-12, using two-stage least square estimation. We found that the sewage subsidy has negative effect on the sewage fee revenue to sewage operation cost ratio. But, the statistical significance of this effect was sensitive to model specification. And the size was too small to conclude that the counter-incentive effect was economically significant.

하수 수중방류에 의한 확산영향 예측

  • Song, Hyeon-U;Kim, Gang-Min;Lee, Jung-U
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.191-192
    • /
    • 2018
  • 해안을 따라 인구밀도가 증가하고 임해지역공단 등 산업시설이 밀집하여 처리되지 않은 하 폐수가 증가하고 있다. 특히, 최근엔 필리핀 보라카이와 같이 관광 위락시설에 의한 하수가 대량으로 발생하고 있다. 또한, 세계적으로 거의 모든 국가의 주요 해안도시는 이러한 도시하수를 바다로 방류하고 있다. 현재로선 이러한 하 폐수의 처리는 바다의 자정능력(self-purification capacity) 한계를 고려한 하수의 해양으로의 방류가 최선의 방법으로 판단된다. 현재 국내에서는 지역에 따른 배출허용기준에 따라 하수의 처리수 방류가 규제되고 있지만, 확산영역에 대한 법적 기준치는 제시되지 않고 있으며, 인근에 위치한 권리자들과의 이해관계 해결에만 몰두하고 있는 실정이다. 또한 확산영향예측이 원역 해석모형(Far Field analysis model)에 의해 수행되기 때문에 근역(Near Field)에서의 영향을 간과하고 있다고 판단된다. 따라서 금회 연구에서는 기존 연구결과를 기준하여 특정해역에 대한 원역과 근역 해석에 따른 확산영향 예측을 수행하고 그 결과를 비교하여 앞으로의 해석방법을 제시하고자 한다.

  • PDF

Hydraulic characteristics and particle behavior in rainwater retention facilities (빗물저류시설에서 수리학적 흐름특성과 입자의 거동)

  • Yoo, Hyoung-Keun;Mun, Jung-Soo;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.141-146
    • /
    • 2008
  • 빗물 유출량 제어를 위한 빗물 저류 시설에서 지금까지는 저류되는 용량이 주된 관심사였다. 많은 물을 순간적으로 저류하여 지체시킴으로서 유출량을 감소시키는 것이 목적이었다. 하지만 이러한 빗물저류시설은 저류기능 뿐만 아니라 침전에 의한 수질개선효과도 가지고 있다. 이렇게 저류된 물을 갈수기에는 화장실 용수나 잡용수로 사용할 수도 있고, 수질 개선을 통하여 하수 오염 부하량의 경감효과까지 노릴 수 있다. 이러한 수질개선 효과를 알아보기 위해서는 빗물 저류시설의 수리학적 흐름특성과 입자의 거동파악이 필수적이다. 본 연구에서는 CFD(Computational Fluid Dynamic)를 이용하여 빗물저류시설 중 하나인 빗물저장조의 수리학적 흐름특성 및 입자의 거동을 살펴보았다. 빗물저장조는 유출입패턴이 불규칙하다. 이를 크게 네 가지 경우로 나누어 살펴보면, 유입만 있고 유출이 없는 경우(Case 1), 유입과 유출이 동시에 있는 경우(Case 2), 유출입이 모두 없는 경우(Case 3), 유출만 있고 유입이 없는 경우(Case 4)로 살펴 볼 수 있다. 기존의 수량 측면에만 한정되었던 빗물 저류 시설에 대한 연구를 수자원 절약과 수질 개선을 통한 하수도 오염 부하량 감소의 측면을 덧붙여 빗물 저류 시설의 목적 범위를 확장할 수 있다.

  • PDF

Feasibility Study on the Treatment of Food Waste Leachate in Municipal Wastewater Treatment Facility - Case of P city - (음폐수 공공하수처리시설 연계처리 타당성 평가 - P시 사례 -)

  • Park, Jong-Hun;Kang, Shin-Young;Kim, Sang-Hyoun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2016
  • P city government considers to treat a part of food waste leachate in a municipal wastewater treatment plant (MWWTP), as the capacity of an existing combined treatment plant for food waste leachate is lower than the generation of food waste leachate in the city. Furthermore, the combined treatment plant also treats landfill leachate and directly discharges the effluent to the sea, which may result in a potential environmental problem. Therefore, this study examined the feasibility of the addition of food waste leachate and the effluent of the combined treatment facility on the MWWTP. Acceptable addition amount of the food waste streams, increased pollution loading on the MWWTP, and the treatment cost were estimated according to four scenarios. All the scenarios estimated that the MWWTP would receive most of the food waste streams according to the manual of the ministry of environment with little increase of pollution loading.

Determination of CSOs Treatment Capacity considering the Pollution Load (오염부하량을 고려한 월류수 처리시설 규모 결정)

  • Kim, Joong Hoon;Yoo, Do Geun;Lee, Eui Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3270-3278
    • /
    • 2014
  • Many researches has been conducted as extreme rainfall in hydrology and extreme rainfall analysis is not proper for determination of CSOs treatment capacity. In this study, runoff is calculated by tranformation from rainfall to runoff according to Interevent Time Definition. The capacity of sewage treatment plant is designed by 3 times of DWF(Dry Weather Flow) and the efficiency of present sewage treatment plant is very low becauseat at present. Also, The sewage treatment plant can not control CSOs. In this research, the pollution load is calculated by EMC(Event Mean Concentration) and pollution concetration of total runoff is a standard deciding suitablility of present sewage treatment plant. Finally, CSOs treatment capacity is determinated considering pollution load.

Numerical Simulation the Effect of Stormwater Treatment on the Water Quality Improvement in a Small Reservoir (초기우수처리에 따른 소규모 저수지 수질개선 효과 수치모의)

  • Ye, Lyeong;Liu, Huan;Lee, Heung-Soo;Kim, Yu-Kyung;Chung, Se-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2064-2068
    • /
    • 2007
  • 합류식 하수도는 오수와 우수를 동시에 배제하는 하수관거 시스템으로 시공이 쉽고 건설비용이 저렴한 반면에 강우시 차집되지 않고 월류되는 유출량으로 인해 수체에 악영향을 초래한다. 관거에서 유출되는 유출수는 강우 초기에 유역에서 집중적으로 유출되는 비점오염원과 하수 및 관거내 오염물질 등을 동반하여 수질 개선을 어렵게 하고 수질 악화를 가중시킨다. 본 연구에서는 기존 유역에 설치된 합류식 하수관거를 분류식으로 개선하고 강우시 초기 세척에 의해 유입하는 비점오염원을 삭감하기 위한 초기우수 처리시설 설치에 따른 M 저수지 수질개선 효과를 수치모델을 사용하여 모의하였다. 저수지의 수질예측은 횡방향 평균 2차원 저수지 수리 및 수질모델인 CE-QUAL-W2를 사용하였다. 저수지 유입량은 군산기상대에서 관측한 일별 강우량 자료를 이용하여 일별 유출량을 산정하였고, 댐 방류량 자료는 M저수지의 2006년 일별 관측수위를 이용하여 유입량과 수위-체적 곡선으로부터 산정하였다. 모델의 보정은 2005년 5월과 8월에 측정한 수질자료를 이용하여 수행하였으며, 저수지의 관측값과 모의결과는 저수지 중앙부 대표지점에서 이루어졌으며, 모델은 관측값을 잘 반영하였다. 모의 결과 M 저수지의 연평균 BOD농도는 합류식(1.25 mg/L)에 비해 분류식 하수 관거(0.91 mg/L)를 도입할 경우 27.2% 개선되었으며, 초기우수 처리시설(0.84 mg/L)을 추가 할 경우 32.8%까지 개선효과가 상승하였다. 기존 합류식 하수관거의 경우 연간 유출부하량은 7,713 kg/yr이었으며, 분류식으로 전환할 경우 2,256 kg/yr, 초기우수처리시설을 추가할 경우 902 kg/yr로 삭감되는 것으로 예측되었다. 분류식하수관거와 초기우수처리를 모두 이행할 경우, BOD와 COD 기준이 호수 수질 기준 II등급 이내로 유지되며, T-P 농도는 0.02mg/L 이하로 유지되어 6월 이후 여름철에 저수지내 조류성장 억제에 효과가 클 것으로 예측되었다. 하수관거 정비사업을 통해 M 저수지는 기존의 농업용 저수지의 목표수질뿐만 아니라, 친수공간으로써 적합한 II등급 수질을 유지할 수 있을 것으로 판단되었다.

  • PDF

A Study on Improving Estimation of Recurrence Rate of Public Water -Jungnangcheon Watershed- (생활용수 회귀수량 산정방법의 개선연구 -중랑천 유역을 대상으로-)

  • Jung, Chung Gil;Ahn, So Ra;Joh, Hyung Kyung;Kim, Seong Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.509-509
    • /
    • 2015
  • 물 수요관리측면에 대한 정책을 수립하기 위해서는 현재 또는 장래에 대한 용수수급의 정확한 이해를 필요로 한다. 이를 위해서는 용수 수요량 및 공급량뿐만 아니라 여러 산정요소를 필요로 하는데, 그 중 회귀수량은 물이 이용되고 다시 하천으로 회귀되어 이용될 가능성이 있는 수량으로 정의되며, 용수수급 및 용수절약 측면에서 회귀 수량은 중요한 요소라 할 수 있다. 회귀수량 조사는 유역조사 사업 이래, 10년간 생?공용수를 중심으로 미시적, 거시적으로 조사를 시행하였으나, 측정 자료의 신뢰도, 조사방법 및 지점선정 등의 문제로 인하여 조사 성과의 활용성이 매우 낮은 실정이다. 수자원장기종합계획등에서는 수자원관련 계획 수립시 생?공용수의 회귀율을 65 %로 적용하고 있으나, 이는 1970년대 말의 사회적 여건 및 경제적 상황이 반연된 결과로 현재 상황에 적용되기 곤란하다. 따라서, 현재 실정에 맞는 회귀율 산정은 반드시 필요하게 된다. 본 연구에서는 기존 생활용수 회귀수량 산정 연구 한계를 보완하고 유역조사 시행을 위한 개선된 회귀수량을 산정하고자 한다. 본 연구는 서울시 중랑물재생센터 처리구역을 기반으로 중랑천유역을 시험유역으로 선정하였다. 기존 회귀수량 산정방법을 개선하기 위해 시험유역 회귀수량 산정을 위한 가용 자료 분석 및 용수흐름 네트워크 공간분석을 추가로 진행하였다. 가용자료로 시험 유역내 상수공급자료(정수장 공급량, 상수계통도, 유수 및 누수율), 하수처리자료(하수처리구역도, 하수처리계통도, 유입량 및 방류량) 및 기상자료(기상청 지점 및 AWS 강우자료)를 구축하였고 각각의 상수계통도 및 하수처리계통도로부터 용수 흐름 네트워크망을 구축하였다. 상수공급자료로부터 상수계통도 공급지역을 구분하여 월별 유수율에 따른 월별 실 공급량을 산정하였다. 하수처리자료로부터 시험유역에서의 월별하수처리 유입량 및 방류량을 산정하였다. 최종적으로 회귀율(하수처리 방류량/실 공급량)을 산정한 결과 연평균 회귀율은 각각 93.97 %(2011년), 95.02%(2012년)로 과잉 추정 되었으며 7 ~ 9월의 회귀율은 110 ~ 120 %로 유입량을 초과하였다. 이는, 하수처리로 유입되는 유입량의 하수관거는 합류식으로 구축되어 7 ~ 9월에 많은 양의 강우량이 우수관을 통해 하수처리장으로 이송되어 생활용수 이외에 자연적인 공급량으로 인한 것으로 분석되었다. 따라서, 월별 회귀율 산정을 위해서는 불투수층에서의 면적강우량(mm)을 유입량(m3/s)으로 환산된 값을 고려하여 회귀율을 재산정하였다. 그 결과 연평균 회귀율은 각각 78.27 %(2011년), 77.58 %(2012년)로 나타났다.각각의 월별 회귀율도 매우 유사하게 나타났으며 과거 관용적으로 사용된 65 % 회귀율보다 약 12 ~ 13%로 증가하였으며 이는, 하수처리시설 구축 및 처리효율의 증가와 상수처리시설의 관로시설의 개량으로 인한 유수율 및 누수율 감소로 회귀율이 증가한 것으로 판단된다.

  • PDF

Investigation of odor Release from Combined Sewer (합류식 하수도의 악취발생 실태 연구)

  • Gil, Kyung-Ik;Shin, Geon-Cheol;Im, Ji-Yeol
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.185-191
    • /
    • 2010
  • This study investigates the odor from combined sewer in urban areas and major odor-causing facilities. Monitorings are conducted in specific areas that have representative characteristics. In combined sewer in urban areas, the real-time monitorings on sulfur, complex odor and specified odor are conducted. And in major odor-causing facilities, the real-time monitorings on complex odor, specified odor are conducted. Odor from combined sewer in urban area is affected by the changes on floating population and the effluent of the septic tank. Also major odor-causing facilities are largely affected by the effluent of the septic tank. The major odor-causing substances are found to be hydrogen sulfide($H_2S$) and methyl mercaptan. To reduce the odor from combined sewer, improvement of effluent from the septic tank and reduction of sulfur compounds have to be done.