• Title/Summary/Keyword: 하수관망

Search Result 82, Processing Time 0.034 seconds

Derivation of the Risk-Safety Factor Relation for Optimal Storm Sewer Design in Urban Area (도시지역의 최적 배수관망 설계를 위한 Risk Safety Factor 관계의 설정)

  • Kim, Mun Mo;Lee, Won Hwan;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.129-134
    • /
    • 1992
  • This paper presents the relation between risk and safety factor for optimal storm sewer design in urban area. For reliability analysis of the storm sewer, uncertainty of the various parameters of constituting equation determining the capacity and load of storm" sewer is considered and risk is determined. In this study, reliability analysis method is applied to Seongsan detention reservoir basin which area is $381,000m^2$ Darcy-Weisbach equation is used for determining capacity of the storm sewer and rational formula is used for determining load. Safety factor representing ratio of the sewer capacity and design flowrate is calculated, and relating with risk. Then risk and safety factor with return period is obtained and it is used for optimal design of storm sewer.

  • PDF

Accuracy evaluation of 2D inundation analysis results of simplified SWMM according to sewer network scale (하수관망 규모에 따른 단순화 SWMM에 대한 2차원 침수분석결과의 정확성 평가)

  • Lee, Jung-Hwan;Kang, Seong-gyu;Yuk, Gi-Moon;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.8
    • /
    • pp.531-543
    • /
    • 2019
  • Constructing a reliable runoff model and reducing model runtime are important in research of real-time urban flood forecasting to reduce the repetitive flood damage. Sewer networks in the major urban basin such as Seoul are vast and complex so that it is not suitable for real-time urban flood forecasting. Therefore, the rainfall-runoff model should be simplified. However, the runoff results due to the simplification of sewer networks can vary depending on the subjectivity and simplification method of the researcher and there is a significant difference especially in 2-D inundation analysis. In this study, the sewer networks in various urban basins with different numbers and distributions of sewer networks were simplified to certain criteria. The accuracy of the simplification model according to the sewer network scale is evaluated by 2-D inundation analysis. The runoff models of Gwanak, Sillim, and Dorimcheon, frequently inundated basins were simplified based on four simplification ranges due to the cumulative drainage area set as a criterion for calculating the simplification range. This study will be expected that the inundation result of simplification models estimated through the analysis can contribute to the construction of a reasonable and accurate runoff model suitable for real-time flood forecasting.

Variability on Urban Runoff using SWMM Modeling According to the Sewer information Error (도시유역 하수관로 관망정보 오차가 SWMM 모형의 유출결과에 미치는 영향 분석 - 도림천 대상유역 -)

  • Hwang, Sung-Hwan;Kim, Min-Seok;Son, Hong-Min;Moon, Young-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.18-18
    • /
    • 2015
  • 현재 국내 도시유역의 유출분석을 위한 많은 모형들 중에서 SWMM 모형은 지표면의 양상, 침투율, 하수관망 체계를 고려한 유출분석이 가능하고, 계산과정에서 부등류를 해석함으로써 하류관로의 배수위 영향을 고려할 수 있는 장점을 가지고 있어 도시유출해석에 많이 이용되고 있는 실정이다. 지하시설물인 하수관로는 유지관리가 어려운 시설물 중 하나이다. 지하에 위치한 하수관망도는 상부 외압에 의한 토양의 유동과 미세한 토류의 변화 등으로 지속적으로 유동이 발생하고 있는 실정이다. 또한, 육안을 통한 조사가 어려운 지하시설물이기 때문에 하수관로 정보의 유지관리가 어려운 실정이다. 맨홀은 하수관거의 제원이 변화된 지점, 흐름방향 및 경사가 급격하게 변하는 지점 등에 위치하고 있어 하수관로 정보를 관리하는 있다. 지하시설물인 하수관로는 관리가 용이하지 않기 때문에 지반침하 등으로 관거의 평균경사 등이 변경될 수 있다. 본 연구에서는 하수관로 상류 및 하류 관저고의 변화에 따른 민감도를 분석하고자 한다. 대상 유역의 모든 관로에 대한 영향을 객관적으로 검토하기 위하여 도시적인 해석을 토하여 관거정보의 오차에 따라서 유출에 미치는 영향을 분석하고 이런 문제를 해결할 수 있는 방안 들을 정리하여 향후, 하수관로 정보의 신뢰성 확보를 위하여 하수관망 정보의 정밀도 문제를 검토하는데 도움이 되고자 한다.

  • PDF

Study on Applying of Unsteady Analysis in ToSS(Total Sewer Operation and Management System) for Optimal Management of Sewer System (하수관망 최적관리를 위한 통합하수관거 시스템의 부정류 해석적용에 대한 연구)

  • Choi, Gye-Woon;Lee, Ho-Sun;Jho, Hyung-Guen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1148-1153
    • /
    • 2005
  • 하수관거는 국민의 정맥이라고 할 수 있을 정도로 도시의 환경관리와 치수, 쾌적한 환경조성에 있어서 매우 중요한 시설이며 그 규모가 광범위하고 복잡한 네트워크로 구성되어 있다. 이러한 하수관망을 통해 이송되는 물은 지저분하고 냄새가 심하기 때문에 지하에 관의 형태로 대부분 시공되어 왔으며, 상수관망처럼 압력관이 아니라 대부분 중력에 의한 이송방식을 채택하고 있어 문제 발생 시 원인파악과 대처를 힘들게 하는 요인을 가지고 있다. 특히 하수관거의 관리 소홀은 곧바로 토양오염과 인근 환경오염으로 직결되며 장기적으로는 상수를 오염시키는 요인으로 작용하므로 체계적인 방법과 장기적인 안목을 가지고 명확한 분석을 시행할 수 있는 시스템을 가지고 최적으로 유지관리 되어야 한다. 최근 들어 이러한 하수도 시설을 효율적으로 관리 및 개선하기 위해 대도시를 중심으로 근거 조사와 정비 사업이 활발히 시행되고 있다. 그러나, 사업효과를 검증하거나 관로의 유지관리를 위하여 국내 실정에 맞지 않는 외국하수관망 흐름 해석 프로그램을 그대로 사용하고 있고 정확한 해석이 이루어지지 않고 있어 효율적인 유지관리가 어렵다. 이와 같은 문제점을 해결하기 위하여 하수관망해석이나 하수관망 정비시 필요한 불명수산정이 가능하고 국내실정에 맞는 프로그램 개발이 시급한 실정이며, 아울러 프로그램을 효율적 운영하고 관리하는 제어관리 기술을 개발, 진행하고 있다. 본 논문에서는 개발된 프로그램의 부정류 해석 기능을 활용하여 대상구역의 해석을 실시하여 기존분석방법의 I/I결과와 비교하였으며 최적관리를 위한 방안을 제시하였다.준편차가 증가하고 있음을 알 수 있다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 하수처리장의 침전지 유입부 설계에 적용하였으며 저류벽의 위치와 폭, 유공정류벽의 유공율에 따른 유입하수의 분배효과를 분석하였다. 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는

  • PDF

A study on simplification of SWMM for prime time of urban flood forecasting -a case study of Daerim basin- (도시홍수예보 골든타임확보를 위한 SWMM유출모형 단순화 연구 -대림배수분구를 중심으로-)

  • Lee, Jung-Hwan;Kim, Min-Seok;Yuk, Gi-Moon;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.81-88
    • /
    • 2018
  • The rainfall-runoff model made of sewer networks in the urban area is vast and complex, making it unsuitable for real-time urban flood forecasting. Therefore, the rainfall-runoff model is constructed and simplified using the sewer network of Daerim baisn. The network simplification process was composed of 5 steps based on cumulative drainage area and all parameters of SWMM were calculated using weighted area. Also, in order to estimate the optimal simplification range of the sewage network, runoff and flood analysis was carried out by 5 simplification ranges. As a result, the number of nodes, conduits and the simulation time were constantly reduced to 50~90% according to the simplification ranges. The runoff results of simplified models show the same result before the simplification. In the 2D flood analysis, as the simplification range increases by cumulative drainage area, the number of overflow nodes significantly decreased and the positions were changed, but similar flooding pattern was appeared. However, in the case of more than 6 ha cumulative drainage area, some inundation areas could not be occurred because of deleted nodes from upstream. As a result of comparing flood area and flood depth, it was analyzed that the flood result based on simplification range of 1 ha cumulative drainage area is most similar to the analysis result before simplification. It is expected that this study can be used as reliable data suitable for real-time urban flood forecasting by simplifying sewer network considering SWMM parameters.

Reliability Analysis of Storm Sewer System by AFOSM Method (AFOSM 방법에 의한 하수관망의 신뢰성 분석)

  • Kim, Mun Mo;Lee, Won Hwan;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.201-209
    • /
    • 1993
  • The purpose of this study is to analyze the reliability of storm sewer system and AFOSM method is applied on Sinjeong detention basin area to decide the applicability of AFOSM method. The Rackwitz Algorithm, which is suitable for minimizing the error due to non-linearity, is used to find the failiure point. The performance functions are established to calculate the risk, rational formula is used to determine the load and Manning equation and Darcy-Weisbach equation are used to determine the sewer capacity, and the results are 0.119, 0.127, respectively. The Risk-Safety Factor relation for each return period is derived and the designing of storm sewer system based on reliability analysis is enabled.

  • PDF

Establishment of Incheon Inundation Production System in association with SWMM-2DIS (SWMM-2DIS를 연계한 인천시 침수심 생산체계 구축)

  • Shim, Jae Bum;Won, Chang Yeon;Hwang, Soo Deok;Lee, Byong Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.387-387
    • /
    • 2019
  • 우리나라는 최근 10년간 자연재난 중 호우로 인해 인명피해 약 120명, 재산피해 약 1조 4천억원을 기록하였으며, 또한 기후변화로 인해 강한 국지성 집중호우의 발생빈도가 높아질 것으로 예상됨에 따라 호우에 의한 침수피해가 증가될 것으로 예상된다. 특히 본 연구 대상지역인 인천시의 경우 도시화로 인해 인구밀도 및 불투수지역이 증가함에 따라 침수피해가 대형화되고 있는 실정이다. 이에 본 연구에서는 인천시와 같은 도심지역에서의 침수발생을 사전에 예측하고 침수발생에 대한 대비 대응을 위해 하수관망 해석을 위한 SWMM 모델과 침수해석을 위한 2DIS 모델을 연계하여 인천시 침수심 생산체계를 구축하고자 한다. 본 연구에 적용한 침수심 생산과정은 크게 강우자료 생산, 유역 및 하수관망 해석, 침수 해석 등 총 3단계 과정으로 구성된다. 강우자료 생산과정에서는 유역 및 하수관망 해석과 침수 해석을 위한 10분 단위 유역평균 강우량자료를 생산한다. 유역 및 하수관망 해석과정에서는 지형자료 및 강우자료를 이용하여 SWMM 모델을 통해 맨홀에서의 월류량 자료를 생산한다. 마지막으로 침수해석과정에서는 지형자료와 함께 앞서 두 과정을 통해 생산된 강우 및 맨홀 월류량 자료를 입력자료로 하여 2DIS 모델을 통해 10분 단위의 시계열 침수심 정보 및 격자별 최대 침수심정보를 생산한다. 본 연구에서의 공간해상도는 도심지역의 도로단위 고해상도 침수심 정보 생산을 위해 6m 단위로 하였으며, 시간해상도는 단시간에 발생하는 도심지역의 침수특성 반영을 위해 10분으로 하였다. 또한, 침수발생 시 발생한 강우의 지표흐름 영향을 반영하기 위해 빗물받이효율 변화에 다른 침수심을 분석하였다. 본 연구를 통해 도출된 모의 침수심 결과를 실제 침수피해사례 및 풍수해저감종합계획 결과와 비교하였으며, 다수 지역에서 실제 침수발생지역과 동일하게 침수가 발생한 것으로 나타났다. 또한, 전체적인 침수 양상이 유사하게 발생함을 확인하였다. 향후 관측자료를 이용한 하수관망 및 침수해석 모델의 최적화, 하천유량 예측을 통한 하류 기점수위의 반영 등을 통해 정확도를 개선할 수 있을 것으로 판단되며, 이를 통해 인천시 침수발생을 사전에 예측하여 침수피해에 대비 및 대응과 침수피해 발생 시 정확하고 상세한 원인 분석 및 예측이 가능할 것으로 기대된다.

  • PDF

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.