• 제목/요약/키워드: 필로티구조

검색결과 39건 처리시간 0.021초

필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로- (A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire-)

  • 황의청;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

Knee - Brace를 활용한 비정형 필로티 건물의 내진보강방안에 대한 해석적 연구 (Analytical Study on the Seismic Retrofit Method of Irregular Piloti Building Using Knee-Brace)

  • 유석형;김달기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.35-42
    • /
    • 2020
  • 필로티 건물의 평면 비정형으로 인한 비틀림 거동은 비틀림 회전 최외단 기둥에 과도한 층간변위를 일으키고 이로 인하여 기둥의 전단파괴를 유도할 수 있다. 필로티 건물의 비틀림 거동을 제어할 수 있는 내진보강 공법으로서 벽체 증설, 철골 프레임 또는 철골 가새 추가공법 등이 사용될 수 있으나 이와 같은 공법 들은 필로티 층의 공간 개방성을 저해할 우려가 있다. 따라서 본 연구에서는 필로티 층의 공간 개방성을 유지할 수 있는 내진보강 공법으로서 knee brace를 활용하기 위하여 knee brace 보강재 단면 형상 및 보강재 설치 각도 등을 변수로 보강된 필로티 건물에 대하여 선형동적해석 및 비선형 정적해석(pushover analysis)을 수행하고 내진성능 평가 및 knee brace의 비틀림 제어효과를 분석하였다. 연구 결과 knee brace로 보강 시 기둥의 전단력은 증가하였으나 비틀림 변형을 제어하는데 효과가 있는 것으로 나타났다. knee brace와 기둥 사이를 30°로 보강 시 60°의 경우보다 기둥의 전단력은 적게 증가하였으며, 단면형상 □, ◯ 그리고 H 순으로 기둥의 횡변위가 적게 발생하였다.

필로티를 갖는 철근콘크리트 전단벽식 건물의 내진성능 (Seismic Performance of Reinforced Concrete Shear Wall Buildings with Piloti)

  • 권영웅;김민수
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.587-594
    • /
    • 2005
  • 최근 판상형 전단벽식 아파트 건물의 고층화와 필로티 설치는 지진발생시 벽량부족현상과 약층 및 연약층을 발생시켜 그 층에서 비탄성 거동이 집중되는 우려가 있다. 본 연구에서는 필로티를 갖는 철근콘크리트 전단벽식 건물에 대하여 FEMA 273과 ATC-40에서 제안하고 있는 성능평가기법을 이용하여 내진성능평가를 실시하고, 그 결과를 비교$\cdot$고찰하였다. 탄성해석을 이용한 내진성능평가 결과, 필로티와 층수에 따라 내진성능지수가 감소되는 것으로 나타났다. 전단벽식 구조물의 경우 강도, 즉 전단응력의 부족 현상이 전체 성능을 지배하고 있었으며, 특히 25층 이상의 경우 그 정도가 더욱 심한 것으로 나타났다. 특히 필로티가 있는 건물에서는 전단응력의 부족과 더불어 약층 및 층 중량 변화가 성능지수의 감소를 초래하고 있어 필로티가 없는 건물에 비하여 성능지수의 감소 경향이 더 크게 나타나는 것을 확인할 수 있었다. 능력스펙트럼을 이용한 비선형정적해석 결과, 층수가 증가하고 필로티가 있는 구조물일수록 성능점이 증가하고 있는 것으로 나타났으며, 평가대상 건물들의 대부분 변형 특성은 인명안전수준에서 허용치를 만족하고 있는 것으로 나타났으나, 25층 이상의 경우 즉시거주 요구수준을 초과하는 것으로 나타났다.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 - (Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.86-94
    • /
    • 2018
  • 제천 스포츠센터 화재로 29명이 사망하고 40명이 부상을 입었다. 이 논문에서는 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 요인을 분석하기 위해 저자의 화재조사 결과를 토대로 건물과 설비의 구조적인 요인을 분석하고 있다. 건물과 설비의 구조적인 요인은 필로티 구조의 주차장, 필로티 주차장과 로비 사이 방화구획 미비, 필로티 주차장에 스프링클러설비 미설치, 1층 주계단에 방화문 미설치, 옥상에 소화수조 미설치, 2층 주출입구에 벽체 매립형 방화문 설치, EPS실 및 배관 피트 층별 방화구획 부실, 배수배관 연결부의 누수, 화물용 승강기의 승강로와 실내에 면하는 벽체에 합판 설치, 폐쇄형 옥상구조로 개조, 주차장 반자 안쪽 천장에 스티로폼 단열재 부착, 2층 여탕 무창층 강화유리 구조, 드라이비트 외벽으로 분석하였다.

고층건물의 필로티 형태별 피크풍압계수 특성에 대한 연구 (A Study on the Characteristics of Peak Wind Pressure Coefficient according to Type of Pilotis of High-rise Buildings)

  • 김근호;유장열;김영문;유기표
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.51-58
    • /
    • 2018
  • Various types of pilotis frames are used on the ground level of high-rise buildings. In some cases, their interior finishing is destroyed by strong winds or typhoons. In the case of a corner pilotis, the peak wind pressure coefficients were greater on the ceiling than they were on the wall for all wind angles. Specifically, on the ceiling portion of a pilotis, the coefficient increased gradually from the outside to the inside in a symmetrical form that centered on the corner edge. However, the minimum peak wind pressure coefficient was greater at the center of the ceiling than it was on the edge of the pilotis' interior. Additionally, the higher the height of the pilotis, the greater the peak wind pressure coefficient was due to the turbulent flow that occurs within a pilotis. In this study, we evaluated peak wind pressures to design an interior finishing for the end edge of a pilotis and for corner piloti. In terms of specific wind angles, the maximum and minimum peak wind pressure coefficients were each observed. They were a maximum of $320^{\circ}$ and a minimum of $270^{\circ}$ for corner piloti and $0^{\circ}$ and $270^{\circ}$, respectively, for the end edge piloti.

금상 진성찬_ 중앙대-The Showroom on counrtyard

  • 한국건축구조기술사회
    • 건축구조
    • /
    • 제12권4호
    • /
    • pp.56-57
    • /
    • 2005
  • 홍대앞의 지상4층, 지하3층의 전시판매시설, 도심지의 부족한 녹지공간을 해소하고자 300평의 대지에 공원을 조성하고 건물은 필로티를 두어 통행과 이동이 용이하도록 하였다. 전체건물은 트러스아치로 이루어진 주 구조체에서 기둥을 내려 각층 슬래브를 받치는 매단구조이며 2개의 도로가 교차되는 지점으로 다수의통행인에 대응하도록 전시실을 케이블로 지지된 캔틸레버로 내밀어 공간을 만들었다.

  • PDF

지진재난 대비를 위한 건축 산업의 발전방향에 대한 고찰 (A Study for the Development Direction of Building Industry in Preparation for Earthquake Disaster)

  • 한동호;김종국
    • 문화기술의 융합
    • /
    • 제4권1호
    • /
    • pp.307-314
    • /
    • 2018
  • 2016, 2017년 연속으로 발생한 경주지진과 포항지진으로 인해 한국사회가 더 이상 지진에 대해 안전하지 않다는 점이 명백해졌다. 불행히도 한국의 건축 산업은 이제까지 지진에 대한 대비가 매우 미흡하여 많은 건물이 지진으로 인해 피해를 입었으며 다음과 같은 문제점이 존재한다. 첫째, 내진성능 확보 비율이 낮다. 둘째, 지진과 화재에 매우 취약한 필로티 구조 건물의 비중이 최근에 매우 높아졌다. 셋째, 안전성 확보를 위한 건축법 적용에서 제외되는 소규모 건축물의 비중이 너무 높다. 넷째, 관행화된 부패와 부실시공이 안전성을 저해한다. 따라서 이러한 상황에서 지진재난 대비를 위한 조치는 다음과 같다. 첫째, 지진에 취약한 건축물의 부족한 내진성능을 확보하기 위해 건물의 구조체를 보강하는 방법과 건물에 작용하는 지진하중을 경감시키는 방법을 활용한다. 둘째, 부패로 인한 부실시공을 방지하기 위해 내부고발자를 활용하고 적극적으로 보호한다. 이를 위해 내부고발자를 조직에 대한 배신자가 아니라 안전이라는 공익을 보호하기 위한 적극적 수단으로 인식해야 한다.

중저층 상부벽식 하부골조 구조의 고유주기 산정식에 관한 연구 (Study on the Equation of Natural Period of Middle and Low Rise Building of Upper-Walled Lower Frame Type)

  • 유석형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.60-67
    • /
    • 2021
  • 국토교통부(2018)의 「필로티 건축물 구조설계 가이드라인」에서는 국내 필로티 형식의 다세대 주택과 같이 중저층의 상부벽식 하부 골조구조를 이루고 있는 복합구조의 고유주기를 안전성을 고려하여 상부 벽식구조에 해당하는 식을 적용하도록 제시하고 있다. 그러나 현행 벽식구조의 고유주기 산정 기준식은 주로 휨 거동하는 고층 벽식구조를 대상으로 한 실측 결과를 통하여 제정된 것으로서 벽체가 전단거동을 하는 국내 4층이하 필로티형 다세대 주택에는 적합하지 않을 것으로 사료되며, 또한, Park et al. (2000)은 해석적 연구를 통하여 10층 이상의 복합구조물의 고유주기에서 하부 골조구조의 영향이 상부 벽식구조보다 크게 작용하고 있음을 확인하였다. 따라서 본 연구에서는 중저층 필로티 구조의 고유주기에 미치는 하부골조의 영향을 검토하기 위하여 상부 벽식구조의 전단 및 휨 강성과 하부골조구조의 전단강성을 변수로 하는 대상 구조물들에 대하여 유한요소 모델을 이용한 고유치 해석과 고유주기 산정 근사식 그리고 현행 고유주기 산정 기준식을 이용하여 고유주기를 산출하고 비교하였다. 비교결과 하부골조의 전단강성변화가 상부벽체의 휨 또는 전단강성의 변화보다 건물 전체의 고유주기에 더 큰 영향을 주는 것으로 나타났다.