• 제목/요약/키워드: 핀 포토다이오드

검색결과 6건 처리시간 0.024초

고체형 검출기를 위한 핀 포토다이오드 제작 (Fabrication of PIN Photodiode for Solid-state Detector)

  • Kwak, Sung-Woo;Gyuseong Cho;Hyungjoo Shin;Park, Seung-Nam
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.98-99
    • /
    • 2003
  • PIN photodiode has been used in solid-state detector for x-ray detection as a photosensor of visible light from scintillator. Since the light from CWO is short wavelength having peak at 490nm, the light is absorbed within a very shallow layer near the surface of the photodiode before arriving at the depletion layer and does not contribute to the signal. In designing the PIN photodiode, it is important to make the p-layer as shallow as possible. (omitted)

  • PDF

Silicon기반 고감도 PIN Photodiode의 전기적 및 광학적 특성 분석 (Analysis of Electrical and Optical Characteristics of Silicon Based High Sensitivity PIN Photodiode)

  • 이준명;강은영;박건준;김용갑;황근창
    • 한국정보통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1407-1412
    • /
    • 2014
  • 근적외선 파장대역 850 nm ~ 1000 nm에서 레이저를 검출하기 위해 포토다이오드의 분광감응도를 향상시키고자 본 논문에서 실리콘 기반 고감도 PIN 포토 다이오드를 제작하고 전기적 및 광학적 특성을 분석하였다. 제작된 소자는 TO-18형으로 패키징 하였고 포토다이오드의 전기적 특성으로 역 바이어스 전압이 5V일 때 암전류는 Anode 1과 Anode 2는 약 0.055 nA 의 값을 나타내었으며 정전용약은 0V 일 때 1 kHz 주파수 대역에서 약 19.5 pF, 200 kHz 주파수 대역에서 약 19.8 pF의 적은 정전용약을 나타내었다. 또한 출력신호의 상승시간은 10 V의 전압일 때 약 30 ns의 고속 응답특성을 확인하였다. 광학적 특성 분석으로는 880 nm에서 최대 0.66 A/W의 분광감응도 값을 나타내었고 1000 nm에서는 0.45 A/W로 비교적 우수한 분광감응도를 나타내었다.

반도체 센서를 이용 방사선 검출기의 ASIC 구현 (ASIC Implementation of Nuclear Radiation Detector Using Semiconductor Sensor)

  • 이운근;백광렬;손창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2353-2355
    • /
    • 2004
  • 본 논문에서는 고정도의 방사선 측정이 가능한 능동형 전자선량계를 제작하기 위해 필수적으로 요구되는 반도체 방사선 검출기를 ASIC으로 구현하였다. 이는 전자선량계의 소형화와 저소비전력을 실현할 수 있도록 전치증폭기와 성형증폭기를 일체화한 것으로 방사선과 방사선 검출 소자인 상용 핀 포토다이오드의 상호작용으로 생성된 수 [nA]의 전류펄스를 측정할 수 있다. MOSIS 공정을 통하여 ASIC으로 구현된 방사선검출기는 $10{\mu}Ci$${\gamma}$-선 Ba-133, Cs-137 및 Co-60의 세 핵종에 대하여 방사선 조사시험을 수행하여 구현된 방사선 검출기의 유용성을 입증하였다.

  • PDF

실리콘 핀 포토다이오드를 이용한 전자 선량계의 설계 및 구현 (A Study on the Development of Electronic Personal Dosimeter with Silicon PIN Photodiode)

  • 이운근;권석근;김중선;손창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2285-2288
    • /
    • 2002
  • Recently, electronic personal dosimeters based upon silicon PIN photodiode or miniature GM tube were developed and have attracted a lot of attention because of the advantages of their nature such as indication of dose rate and the cumulative dose, and facilitation of record keeping. In this paper, we have developed a high-sensitivity electronic personal dosimeter with silicon PIN photodiode. The electronic personal dosimeter is constructed with silicon PIN photodiode, preamplifier, and shaping amplifier. To show the effectiveness of electronic personal dosimeter, we conducted nuclear radiation experiments using $\gamma$-ray Ba-133, Cs-137, and Co-60. The electronic personal dosimeter have a good linearity on $\gamma$-ray energy and activity.

  • PDF

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

핀 포토다이오드를 이용한 보급형 라돈 검출기의 구현 (Implementation of Popular Radon Detector Using Pin Photodiode)

  • 윤성하;김재학;김규식
    • 전자공학회논문지
    • /
    • 제53권11호
    • /
    • pp.99-106
    • /
    • 2016
  • 라돈이 기관지나 폐포에 머무르게 될 때 라돈의 붕괴로 인해 자핵종(알파선, 베타선, 감마선 등)들이 생성되면서 이것들이 방사선을 방출하는데 세포의 염색체에 돌연변이를 일으켜 폐암을 발생할 가능성이 존재한다. 다시 말해 폐암의 원인이 라돈가스 때문이라기보다는 흡수된 일부 라돈의 붕괴로 인해 생기는 부산물이 방사선을 방출하기 때문이라고 할 수 있다. 사람이 연간 노출되는 방사선의 82%가 자연방사선에 의한 것인데 그중 대부분이 라돈이다. 실내의 라돈 농도를 적절하게 제어할 수 있다면 폐암의 발생확률을 30%나 억제할 수 있다고 알려져 있다. 아직까지 실내의 라돈의 농도를 측정하는 데는 외국의 라돈 센서를 사용하고 있는 실정이다. 실내 라돈 방출량에 대한 데이터 구축과 국내에 맞는 실용적인 라돈측정기기를 개발하도록하는 연구가 필요하다. 본 논문에서는 PIN Photodiode를 이용하여 라돈의 농도를 측정하는 라돈 검출기 구현 방법을 제안한다. 실험을 통해서, PIN photodiode의 라돈 센서 모듈로서의 이용 가능성에 대하여 확인하였다.