• Title/Summary/Keyword: 핀성능

Search Result 343, Processing Time 0.022 seconds

The Performance Analysis of the Fin-Tube Heat Exchanger Using CFC Alternative Refrigerant (CFC 대체냉매를 사용한 핀-관 열교환기의 성능해석)

  • 박희용;박경우;차재병
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2358-2372
    • /
    • 1993
  • In this study, the computer modeling for prediction of the performance of fin-tube heat exchanger using alternative refrigerant, HFC-134a was developed and the computer program for calculating the various properties of HFC-134a and the existing refrigerant CFC-12 and HCFC-22 was made. The heat exchanger modeling is based on a tube-by-tube approach, which is capable of analysis for the complex coil array. Performance of each tube is analyzed separately by considering the cross-flow heat transfer with external airstream and the appropriate heat and mass transfer relationships. A performance comparison according to the different refrigerants is provided using this developed model. As the result of this study, total heat transfer rate of evaporator and condenser using HFC-134a were found higher than that of using CFC-12 for the same operating conditions. When the mass flow rate of HFC-134a was less than CFC-12 about 18. 16%, the cooling capacities of evaporator were found to be the same.

The Effect of PVE Oil on the Evaporation/Condensation Heat Transfer Performance of Fin-tube Heat Exchanger (핀-튜브 열교환기에서 PVE오일이 증발/응축 열전달 성능에 미치는 영향)

  • Lee, Hyun-Woo;Jeong, Young-Man;Lee, Jae-Keun;Park, Nae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1067-1072
    • /
    • 2009
  • In vapor compression systems which use refrigerant as a working fluid, the oil is commonly used for compressor lubrication. Since the presence of lubrication oil can change the characteristics properties of refrigerant, the oil affects the heat transfer performance of heat exchanger to a large extent. In this paper, we focus on the effect of PVE oil experimentally on heat transfer performance of the fin-tube heat exchangers which use R410A as a refrigerant. To evaluate the heat transfer performance, the refrigerant to air type test facility chamber has been used. Fin-tube heat exchanger with grooved has been tested while according to the oil mass fraction variation from nearly zero to 1.7 wt%. It was found that the low level of oil mass fraction has an obvious effect on heat transfer performance, while the high level seems no significant influence. The influence of the oil mass fraction to heat transfer performance, however, is different between evaporation and condensation.

  • PDF

Effect of Oxidation of Graphene Nanoplatelets on the Mechanical Properties and Bonding Performance of Epoxy Paints (그래핀 나노플레이트릿의 산화가 에폭시 도료의 역학적 특성 및 부착 성능에 미치는 영향)

  • Chum, Sung-Ho;Kim, Gyu-Yong;Lee, Sang-Kyu;Hwang, Eui-Chul;Son, Min-Jae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.31-32
    • /
    • 2019
  • In this study, oxidized graphene nanoplatelet(GO) was prepared by oxidizing graphene nanoplatelet(GNP) with nitric acid in order to solve the problem of dispersion of GNP, one of nano materials. GNP/Epoxy and GO/Epoxy paint were prepared by mixing GNP, GO with 0.1, 0.3, 0.5 and 1.0 wt.% in epoxy paint and the mechanical properties were evaluated. As a result, GNP/Epoxy and GO/Epoxy paints showed better mechanical properties than Neat Epoxy which did not incorporate GNP, GO. Especially, when 0.3 wt.% of GO was incorporated into epoxy resin, it showed higher tensile strength than Neat Epoxy. It was confirmed that acid treatment of GNP was effective in improving the mechanical properties of epoxy paint. However, graphene material was found that it was not effective in improving the bond performance of the epoxy paint.

  • PDF

Modified Hairpin Filters Improving the Suppression Performance of Stop-Band (저지 대역 제거 특성을 향상시킨 변형된 헤어핀 여파기)

  • Kim, Bong-Su;Kang, Min-Soo;Byun, Woo-Jin;Kim, Kwang-Seon;Song, Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • In this paper, a new hairpin type strip-line BPF(Band Pass Filter) improving the suppression performance of unwanted frequency signal is studied. A modified hairpin filter is designed by classical hairpin filter design methodology and is realized by newly placing structure of designed filter. And a newly formed coupled-line effects between modified bilateral symmetry structures make the transmission zeros. Each transmission zeros can shift its frequency to wanted frequency by tuning a certain part of filter. To investigate the validity of this novel technique, an order-5 Chebyshev BPF centered at 9.2 GHz with a 15 % FBW(fractional bandwidth) were used. According to design and measurement results, a good performance of insertion loss of 0.8 dB and unwanted signal suppression of maximum 50 dB is achieved at full input/output ports.

Unwinding Behavior of and Load Prediction for Protective Tube Around Fiber-Optic Cable (보호 튜브의 풀림 거동 및 하중 예측)

  • Kim, Kun Woo;Lee, Jae Wook;Kim, Hyung Ryul;Yoo, Wan Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.235-241
    • /
    • 2014
  • As a fiber-optic cable is being unwound, it is protected by a tube that is designed to prevent unwinding problems such as tangling and unintentional cutting. In addition, a guide body is separated from the protective tube if a shear pin breaks when the maximum allowable load is exceeded. Therefore, it is important to analyze and predict the unwinding behavior of the protective tube, as well as the load on the shear pin, to enhance the likelihood of a successful operation when laying cables at extreme depths. In this study, the protective tube and the guide body are modeled with particles and are constrained with a constant-length constraint. The load on the shear pin was verified against experimental data, and the unwinding behavior was predicted from the load prediction results.

Performance Analysis of Stabilizer Fin Applied Coanda System (코안다 시스템이 장착된 안정기용 핀의 성능해석)

  • Seo, Dae-Won;Lee, Se-Jin;Oh, Jungkeun
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • Stabilizer fins are installed on each side of a ship to control its roll motion. The most common stabilizer fin is a rolling control system that uses the lift force on the fin surface. If the angle of attack of a stabilizer fin is zero or the speed is zero, it cannot control the roll motion. The Coanda effect is well known to generate lift force in marine field. The performance of stabilizer fin that applies the Coanda effect has been verified by model tests and numerical simulations. It was found that a stabilizer fin that applied the Coanda effect at Cj = 0.085 and a zero angle of attack exactly coincided with that of the original fin at α = 26°. In addition, the power needed to generate the Coanda effect was not high compared to the motor power of the original stabilizer fin.

Heat Transfer and Combustion Characteristics and Performance of U type Radiation Tube Burner with fin (핀 부착 U형 복사튜브 버너의 열전달 및 연소성능 실험)

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.516-521
    • /
    • 2001
  • Present study deals with combustion characteristics and performance of U type radiation tube burner with fin which combustion capacity is 30,000kcal/hr and the maximum capacity of supply fuel is $30Nm^{3}/hr$. Temperature difference of radiation tube is about $173^{\circ}C$ at 25% capacity and this show relatively small temperature difference for convenient type. Thermal efficiency is satisfactory as $72{\sim}81%$. Also, radiative efficiency of radiation tube is $52{\sim}73%$. The efficiency of heat exchanger is $27{\sim}37%$. Therefore, radiative efficiency is improved to $1{\sim}10%$ after installing fin.

  • PDF

CFD ANALYSIS OF HEAT TRANSFER PERFORMANCE OF A REFRIGERATOR CONDENSER (CFD 해석을 통한 냉장고용 응축기 전열성능 연구)

  • Yoo, S.S.;Hwang, D.Y.;Lee, M.S.;Han, B.Y.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.303-309
    • /
    • 2009
  • In this study, the heat transfer and flow field of condenser used on Kim-chi refrigerator is analysed with numerical method. Main objective is to present the base data for designing new condenser model with improvement of heat transfer performance. For CFD analysis, a commercial code, STAR-CCM+ was used. The water was used for the inner working fluid and the air was used for the outer fluid. The condenser type used in this study is a flat plate fin-and-tube heat exchanger. As factors for performance analysis, the effect of condenser geometry and air velocity was investigated. As a result, it has been observed that there is a suitable fin pitch with which heat transfer performance of condenser is maximized.

  • PDF