• Title/Summary/Keyword: 피폭형태

Search Result 93, Processing Time 0.03 seconds

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

The apoptotic fragment assay in rat peripheral lymphocytes and crypt cells with whole body irradiation with 60Co ϒ-rays and 50 MeV cyclotron fast neutrons (코발트-60 감마선과 50 MeV 싸이크로트론 고속 중성자선에 전신조사된 랫드의 말초 임파구와 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.203-210
    • /
    • 2001
  • Here, we compared the effectiveness of 50 MeV($p{\to}RBe^+$) cyclotron fast neutrons versus $^{60}Co$ ${\gamma}$-rays by the apoptotic fragment frequency in both rat peripheral lymphocytes and crypt cells to check a radiobiological endpoint. The incidence of apoptotic cell death was increased in all irradiated groups, and radiation at all doses trigger rapid changes in both crypt cells and peripheral lymphocytes. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for these data of apoptotic fragments frequencies was $y=0.3+(6.512{\pm}0.279)D(r^2=0.975)$ after neutrons, while $y=0.3+(4.435{\pm}0.473)D+(-1.300{\pm}0.551)D^2(r^2=0.988)$ after ${\gamma}$-rays. In addition, $y=3.5+(118.410{\pm}10.325)D+(-33.548{\pm}12.023)D^2(r^2=0.992)$ after ${\gamma}$-rays in rat lymphocytes. A significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic cells with increasing dose. Dose-response curves for high and low linear energy transfer (LET) radiation modalities in these studies were different. The relative biological effectiveness (RBE) value for crypt cells was 1.919. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morphological findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis induction in both crypt cells and peripheral lymphocytes could be a useful endpoint of rat model for studying screening test and microdosimetic indicator to evaluate the biological effects of radiation-induced cell damage.

  • PDF

고선량율 근접치료의 위험도 분석

  • 최진호;이레나;이상훈;이세병;이희석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.57-57
    • /
    • 2003
  • 목적 : 미국 NRC 의 위험도 평가 방법론(NUREG/CR-6642)에 국내에서 시행되는 고선량율 근접치료의 표준입력 자료를 대입하여 고선량율 근접치료시 위험도를 정량적으로 산출하고 그 값을 비교하고자 한다. 대상 및 방법 : 고선량율 근접치료 시스템에 대한 위험도 평가를 위해 국내에서 고선량율 근접치료를 시행하고 있는 17개 의료기관으로부터 방사성동위원소의 설치와 폐기시의 방사능, 선원의 유형, 연간 총 치료회수 등 기초 자료를 수집하였다. 이로부터 방사성동위원소의 평균세기 연간 치료회수 등을 미국 NRC의 위험도 평가 방법론의 데이터베이스에 입력하여 고선량율 근접치료의 직무별, 피폭인의 종류, 정상상태와 사고 등의 형태에 따라 그 위험도를 구하였다. 결과 : 국내 고선량율 근접치료의 위험도는 미국 NRC의 위험도 평가 방법론에 따른 데이터베이스의 입력 결과 일반인의 정상상태와 사고 그리고 방사선종사자의 정상상태와 사고 시에 따라 그 위험도가 1.52-01, 2.96-03, 8.64-01, 3.32-02 rem/yr로 산출되었고 그 값을 미국 NRC의 값과 비교하였다. 결론 : 고선량율 근접치료 시 미국 NRC의 위험도 결과보다는 국내의 경우 수배 정도 높게 계산되었고 일반인과 방사선종사자, 정상상태와 사고, 직무별 패턴 등은 동일한 것으로 간주된다.

  • PDF

Comparative Risk Assessment Methodology: An Application to Air Pollution (비교 위험도 평가 방법의 대기 오염에 대한 적용 연구)

  • Lee, Jin-Hong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.100-104
    • /
    • 1992
  • The research in this paper centers on a comparative risk assessment for nearby air pollution by carcinogenic metal emission from municipal solid waste incinerators. If a substance is identified as a potential human carcinogen, the carcinogenicity may be related to the chemical form of a substance and the route of exposure. This type of information with regard to carcinogenic uncertainty is incorporated into hazard quantification. In addition to the dioxin emission, the metal emission from municipal solid waste incineration is found to be a major contributor to human cancer risk via the inhalation route. The magnitude of risk by metals is about 5 times greater than that of risk by dioxins. Hexavalent form of chromium and cadmium compounds are major contributors to cancer risk from metal emission. In addition, hexavalent chromium is known to be human carcinogen while 2,3,7,8-TCDD is known to be only probable human carcinogen.

  • PDF

A Conservative Safety Study on Low-Level Radioactive Waste Repository Using Radionuclide Release Source Term Model (선원항 모델을 사용한 저준위 방사성폐기물 처분장의 보수적인 안전성고찰)

  • Kim, Chang-Lak;Lee, Myung-Chan;Cho, Chan-Hee
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.63-70
    • /
    • 1993
  • A simplified safety assessment is carried out on rock-cavern type disposal of LLW using the analytical repository source term (REPS) model. For reliable prediction of the leach rates for various radionuclides, degradation of concrete structures, corrosion rate of waste container, degree of corrosion on the container surface, and the characteristics of radionuclides are considered in the REPS model. The results of preliminary assessment show that Cs-137, Ni-63, and Sr-90 are dominant. For the parametric uncertainty and sensitivity analysis, Latin hypercube sampling technique and rank correlation technique are applied. The results of the potential public health impacts show that radiological dose to intruder in the worst case scenario will be negligible and that more attention should be given to near-field performance.

  • PDF

Search for the activity measurement of radionuclides I-131 (131I을 이용한 방사능 측정에 관한 연구)

  • Baek, Seong-Min;Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • Iodine is one of important nuclides to be checked for radiation exposure after nuclear power facility accidents. After Chernobyl accident, it was observed that there is a greater amount of organic iodine in the atmosphere than inorganic iodine. In this study, we not only varied the amount of sample being exposed to $^{131}I$ and the duration of exposure to $^{131}I$ but also diluted the sample in distilled water and mixed the sample in kelp and liquid $^{131}I$ to measure and analyze the radiation detection levels. We concluded that the radiation levels were not high enough to be harmful to human body. The radiation from $^{131}I$ decreased over time, and we calculated the half life at 7-9 days. We found that the radiation from any sample containing $^{131}I$ was halved by up to 7days.

Study on Pre-treatment Method for Vitrification of Concentrated Wastes (농축폐기물 유리화를 위한 전처리 방안 연구)

  • Cho, Hyun-Je;Kim, Deuk-Man;Park, Jong-Kil
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.221-227
    • /
    • 2010
  • The solidification methods for powder wastes dried at CWDS(Concentrate Waste Drying System) in PWR have been studied in a variety of ways both at home and abroad. The solidification for these wastes has been performed using stabilization agents such as cement, paraffin and polymer. The applicability studies to maximize the reduction ratio of wastes and operational effectiveness for wastes treatment have been carried out, recently. It is necessary to pretreat the powder wastes before feeding wastes to vitrification facility because the fines flying brings about clogging of feeding pipes and off-gas treatment system or workers' exposure to radiation during maintenance. This paper describes an effective method for treatment of powder wastes to improve safety and stability of vitrification facilities.

The Study of Optimal Acquisition Condition and Image Processing (최적의 촬영조건 및 영상처리에 관한 연구)

  • Lee, Yong-Gu;Shin, Jong-Ho;Seo, Kyoung-Eun;Choi, Yoo-Lee;Lee, Soo-Hyeon;Lee, Young-Jin;Kim, Hee-Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.221-226
    • /
    • 2014
  • In this paper, we achieved the study which determined the excellent diagnostic condition and searched the exposure condition with the minimum radiation exposure level having the equal diagnostic ability. To accomplish these study, chest phantom images with lesions and without ones were evaluated at various exposure conditions. With respect to the phantom with lesions and without ones, we obtained the chest PA imaging applied by photographing parts of DR apparatus and the images processed as histogram equalization and edge enhancement method. The images were acquired at the exposure conditions of 2.0, 2.5, 3.2, 4.0 and 5.0mAs. The morphological analysis was performed by ROC curves using the images obtained at each exposure condition. The exposure conditions with the most excellent diagnostic ability and with the equal diagnostic capability having the minimum radiation exposure level were determined by means of sensitivity, specificity and accuracy.

Analysis of Chromosome aberrations by fluorescence in situ hybridization using triple chromosome-specific probes in human lymphocyte exposed to radiation (3중 DNA probe를 이용한 FISH(fluorescence in situ hybridization) 기법으로 방사선에 의한 염색체 이상 분석)

  • Chung, Hai-Won;Kim, Su-Young;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 1999
  • Fluorescence in situ hybridization with chromosome-specific probe has been shown to be a valid and rapid method for detection of chromosome rearrangements induced by radiation. This method is useful for quantifying structural aberrations, expecially for stable ones, such as translocation and insertion, which are difficult to detect with conventional method in human lymphocyte. In order to apply FISH method for high dose biological dosimetry, chromosomal abberations by radiation at doses of 1, 3, 5, and 7Gy were analysed with whole chromosome-specific probes by human chromosome 1, 2 and 4 according to PAINT system. The frequencies of stable translocation per cell equivalent were 0.04, 0.33, 1.22, 2.62, and 5.58 for the lymphocyte exposed to 0, 1, 3, 5, and 7Gy, respectively, and those of dicentric were 0.00, 0.06, 0.52, 1.19 and 2.44, respectively. Significantly more translocation of t(Ab), a translocated chromosome with a piece of painted acentric matrial 'b' attached to unpainted piece containing centromere 'A', than reciprocal chromosome t(Ba) was observed. The frequencies of all type of chromosome rearrangements increased with dose. From above result, FISH seemed to be useful for radiation biodosimetry by which the frequencies of various types of stable aberrations in human lymphocyte can be observed more easily than by conventional method and so will improve our ability to perform meaningful biodosimetry.

  • PDF

Fine Structural Modification of Mouse Ovarian Tissue by Irradiation of 6 MeV LINAC Radiation (6 MeV LINAC 방사선 조사에 의한 생쥐 난소조직의 미세구조 변화)

  • Yoon, Chul-Ho;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.33 no.2
    • /
    • pp.117-130
    • /
    • 2003
  • This research investigates the fine structural as well as the morphological changes of the mouse ovarian tissue after irradiation of various dose rates of 6 MeV LINAC radiation. The normal structure of the ovarian tissue is consisted of various stages of follicles including primordial and growing follicles, and ovarian stromal connectives. When we observed the ovarian tissues irradiated with a dose rate of 200 cGy/min using light and electron microscopes, granular cells in growing follicles are in irregular shape unlike normal follicles. Small segments of cells scattered in follicular antrum among granular cells. We could observe neutrophils and macrophages around the segments, which means the cells already got in the process of decease owing to the effects radiation. With coincident to the increase of the dose rate of x-ray irradiation as 400 or 600 cGy/min, the mature follicles appeared as an irregular form and the granular cells surrounding oocyte also deformed comparing to their normal counterparts. The granulosa cells within mature follicle are already occurred necrotic change and apoptosis. The nuclei in some cells got so fragmented that the segments formed the shape of a horseshoe or scattered in small and condensed pieces. All the cells at a granular layer irradiated with a dose rate of 600 cGy/min show typical characteristics of apoptosis. The neutrophils involved in inflammatory reaction appear evidently in follicular antrum of growing follicles, and macrophage scattered with residual and apoptotic bodies.