• Title/Summary/Keyword: 피폭저감

Search Result 146, Processing Time 0.023 seconds

A Study on the Development of Optimization Procedure for Radiological Protection (방사선 방어의 최적화 절차론 개발에 관한 연구)

  • Song, Jong-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 1994
  • Considering the variety of application and other factors in performing the optimization of radiological protection, it is necessary to use well-structured optimization procedure. In this study, an optimization procedure for design stage of nuclear power plant was proposed, and applied in the selection of alternatives for reducing occupational radiation exposure. As an aiding technique for decision-making, multi-criteria technique was used. As a result, priorities of alternatives are determined, and a problem of applying this result to real situation is reviewed. The developed procedure for optimization can be extended to other areas such as radioactive waste management, medical use of radiation, etc.

  • PDF

COINS- I : 가상발전소 개념에 따른 원자력 극한작업을 위한 지능형 상호협조 훈련시스템의 모델링

  • Cha, Kyungho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.608-613
    • /
    • 1996
  • 본 논문에서는 고온, 고압, 그리고 방사능 준위가 높은 원자력발전소 구조물의 극한환경(Hazardous Environments)에서의 점검 및 보수에 대한 작업자의 훈련을 위해 지능형 상호협조 훈련시스템 (COINS-I: COoperative INtelligent training System-I)의 개념모델을 제안하였다. 비교적 방사능준위가 높은 격납용시 구조물과 보조(Auxiliary) 빌딩을 일차적 극한작업환경으로 설정하였다. 격납용기 구조물과 보조빌딩에 대한 가상발전소 환경(Virtual Plant Environments)을 모델링하여, 극한환경에서의 점검 및 보수훈련 Pilot 연구를 COINS-I의 개발목적으로 하였다. COINS-I은 점검, 보수훈련을 위한 가상발전소 환경을 갖는 극한작업 시뮬레이터, 지능형 Tutoring 기능을 갖는 극한작업 훈련프로그램, 3차원 가상인터페이스 등의 훈련장비를 갖는 훈련설비로 구성된다. COINS-I을 통한 교육 및 훈련 궁극적으로 작업자가 경험치 못한 극한작업(예를들면, 원자로해체, 중대사고, Life-extension 등)의 가상 시뮬레이션을 통한 훈련이 가능하여 방사능 피폭량을 저감하며, 극한작업 자동화를 위한 연구에의 활용이라 하겠다.

  • PDF

The Consideration of nuclear medicine technologist's occupational dose from patient who are undergoing 18F-FDG Whole body PET/CT : Aspect of specific characteristic of patient and contact time with patient (18F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰: 환자 고유특성 및 응대시간 측면)

  • Kim, Sunghwan;Ryu, Jaekwang;Ko, Hyunsoo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.67-75
    • /
    • 2018
  • Purpose The purpose of this study is to investigate and analyze the external dose rates of $^{18}F-FDG$ Whole Body PET/CT patients by distance, and to identify the main factors that contribute to the reduction of radiation dose by checking the cumulative doses of nuclear medicine technologist(NMT). Materials and Methods After completion of the $^{18}F-FDG$ Whole Body PET/CT scan($75.4{\pm}3.3min$), the external dose rates of 106 patients were measured at a distance of 0, 10, 30, 50, and 100 cm from the chest. Gender, age, BMI(Body Mass Index), fasting time, diabetes mellitus, radiopharmaceutical injection information, creatine value were collected to analyze individual factors that could affect external dose rates from a patient's perspective. From the perspective of NMT, personal pocket dosimeters were worn on the chest to record accumulated dose of NMT who performed the injection task($T_1$, $T_2$ and $T_3$) and scan task($T_4$, $T_5$ and $T_6$). In addition, patient contact time with NMT was measured and analyzed. Results External dose rates from the patient for each distance were calculated as $246.9{\pm}37.6$, $129.9{\pm}16.7$, $61.2{\pm}9.1$, $34.4{\pm}5.9$, and $13.1{\pm}2.4{\mu}Sv/hr$ respectively. On the patient's aspect, there was a significant difference in the proximity of gender, BMI, Injection dose and creatine value, but the difference decreased as the distance increased. In case of dialysis patient, external dose rates for each distance were exceptionally higher than other patients. On the NMT aspect, the doses received from patients were 0.70, 1.09, $0.55{\mu}Sv/person$ for performing the injection task($T_1$, $T_2$, and $T_3$), and were 1.25, 0.82, $1.23{\mu}Sv/person$ for performing the scan task($T_4$, $T_5$, $T_6$). Conclusion we found that maintaining proper distance with patient and reducing contact time with patient had a significant effect on accumulated doses. Considering those points, efforts such as sufficient water intake and encourage of urination, maintaining the proper distance between the NMT and the patient(at least 100 cm), and reducing the contact time should be done for reducing dose rates not only patient but also NMT.

Recycling of Safety Check Valves Contaminated with Radioactivity by Chemical Decontamination (化學除染에 의한 逆止밸브의 再使用)

  • 정종헌;최왕규;원휘준;심준보;오원진
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2001
  • Chemical decontamination techniques have been employed to reuse the high cost check valves contaminated with radioactivity and to reduce the radiation exposure during the inspection and maintenance work of safety injection system containing check valves. After chemical decontamination, an ultrasonic treatment was conducted to remove the fine solid particles retained in the crevices of check valves. The decontamination process conditions and the amount of chemical reagents were determined from the results of a pre-test, using the (list arm holder. The decontamination factors (DF), estimated from the activity in the solution, ranged from 14.5 to 18.5 corresponding to the activity removal of 93-95ft. The corrosion test data indicated that the general corrosion rate during a chemical decontamination-ultrasonic treatment process are low for type 304 S tainless steel, Inconel -600 and Stellite-6 materials $ (2.1\times10^{-2}$ $6.0\times10^{-2}$ and$ 1.7\times10^{-2}$ mil, respectively).

  • PDF

Evaluation of the Effectiveness of 3D Printing Shielding Devices using Monte Carlo Simulation in Plain Radiography (일반영상 검사 시 몬테칼로 시뮬레이션을 이용한 3D 프린팅 차폐기구의 효용성 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.303-311
    • /
    • 2020
  • Scattering-ray generated during plain radiography can cause secondary exposure to organs and tissues other than the target area. Currently, Shielding devices used to reduce radiation exposure are mostly used for radiation protection of workers, and radiation protection of patients is rarely performed. Therefore, this study intends to evaluate the organ dose by scattered-rays and the effectiveness 3D printing materials as a radiation shielding device during plain radiography through simulation. As a result, the absorbed dose for each organ at the time of examination showed a high effect due to the secondary scattering-ray as the distance from the source was close and the organ closer to the skin surface. The dose reduction effect due to the use of 3D printing shielding devices to protect this showed a higher shielding effect in the case of mixed printing materials compared to plastics.

Effect of Stitching Range on Radiation Dose to Eyeball, Thyroid, Breast, Pelvis in Whole Spine Radiography with Standing Position (선 자세 척추 전장 방사선검사 시 스티칭 범위가 장기(수정체, 갑상샘, 유방, 골반부)의 선량에 미치는 영향)

  • Min-Ji, Hong;Han-Yong, Kim;Dong-Hwan, Kim;Young-Cheol, Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.47-52
    • /
    • 2023
  • In whole spine radiography using the stitching technique, overlapping parts occur in the process of synthesizing the three segmented images, so some anatomical structures may be repeatedly exposed, and it has been thought that the dose increases as the scan range increases. However, in the whole spine radiography using the stitching technique in this study, under the condition that the stitching range is taken in the same three splits, the overlapping area decreases as the stitching range increases, so in the case of breasts included in the overlapping range, the dose value decreased by almost half as the stitching range increased from 90 cm to 105 cm. During spinal full-length radiological examination using the stitching method, an appropriately long stitching range could be set to reduce the exposure dose of the breast.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

  • PDF

The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System (디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구)

  • Park, Ji-Koon;Jung, Bong-Jae;Park, Hyong-Hu;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.109-115
    • /
    • 2016
  • Despite of increasing the use of the digital imaging device in the radiology area, the setting on the optimal irradiation conditions are insufficient. In this study, the exposure dose and image quality by exposure condition of digital radiography device were compared. The exposure doses were obtained by adjusting the exposure condition as 5 steps respectively based on the exposure conditions that are currently used of CR and DR radiography devices. The acquired image has been assessed by 20 medical image professors using the assessment method of the Japanese Society for Tuberculosis Prevent. As a result, in the case of the CR system, the better image quality was obtained in the condition of 120 kVp and 1.5 mAs~2.4 mAs (quality score 91~95.5 points) than standard exposure condition(110 kVp, 3.2 mAs, 86 points). And exposure dose was evaluated as low with $61.3{\sim}98.4{\mu}Gy$ than standard condition($105.11{\mu}Gy$). In DR system, however, the image quality score was higher as 97~98.6 points in the lower tube voltage range (112 kVp, 2.4~3.2 mAs) condition than the standard exposure condition (125 kVp, 3.2 mAs, 91 points). In addition, the exposure dose was $61.5-77.2{\mu}Gy$ lower than standard condition($93{\mu}Gy$). In addition, the exposure dose was low as $61.5-77.2{\mu}Gy$ than standard condition($93{\mu}Gy$). With the results of this study, we confirmed that it is possible to reduce the patient exposure dose with the same image quality by adjusting the optimal exposure condition of digital device.