• Title/Summary/Keyword: 피팅면적

Search Result 8, Processing Time 0.023 seconds

Pitting Life Experiments of Gear Material using a Damaged Area Analysis Method (피팅 파손면적분석기법을 이용한 기어재의 피팅 수명 실험)

  • Joo, Jin-Wook;Lee, Byung-Wook;Moon, Seok-Man;Kim, Tae-Wan;Cho, Yong-Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.92-97
    • /
    • 2010
  • The object of this study is to investigate the definite method for pitting damaged surfaces. Pitting is a sort of fatigue damages and it is made by a repetitive load. For a judgment between damages or not, sensing vibrations of test equipment is simple. However, it is not only difficult to observe a growth of pitting but also impossible to detect the juncture of initial pitting. Therefore, a method for the pitting damaged area measuring technique was effectively implemented by Two Roller Machine. The change of surface damaged area was measured by an optical microscope in regular time and calculated by the use of dark and bright ratio of test specimens' pictures taken by optical microscope. In conclusion, S - N Curves gained by Failure rate - Cycle graph was led and the curves are able to be chosen as occasion demands for a failure area percentage.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

Characterization of PEMFC Electrode Structures by Complex Capacitance Analysis of EIS (임피던스 복소캐패시턴스법에 의한 PEMFC 전극 구조 분석)

  • Jang, Jong-Hyun;Son, Ji-Hwan;Kim, Hyoung-Juhn;Han, Jong-Hee;Lim, Tae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.213-216
    • /
    • 2007
  • PEMFC의 전기화학적 반응은 촉매, 이오노머, 기공이 만나는 삼상계면에서만 일어나므로, 전극 구조의 최적화가 성능 향상 및 장기안정성 확보에 있어 매우 중요하다. 본 연구에서는 전극 미세구조를 실시간으로 분석하기 위해 임피던스 복소캐패시턴스법을 도입하고자 하였다. 즉, PEMFC의 양극에 질소를 공급하면 0.4 V 부근에서 전기이중층 형성 반응만이 일어나는 것을 확인하였으며, 이때 음극에는 수소를 공급하여 기준전극 및 반대전극으로 사용하였다. 측정된 임피던스를 복소캐패시턴스로 변환하고 허수부를 주파수에 대해 도시하면 피크 형태의 곡선이 얻어지는데, (1) 피크 면적은 전극/전해질의 계면면적, (2) 피크 위치는 이오노머 네트워크에 의한 수소이온 전도 특성, (3) 피크 폭은 다공성 구조의 균일도를 각각 나타내므로, 피팅 없이 직접적인 해석이 가능하다는 장점을 가진다. 반면, 기존의 Nyquist 도시법은 피팅에 의한 분석이 필요하며, 전극층의 불균일한 구조로 인해 단순한 등가회로 구성이 어려운 문제점을 가진다. 최종적으로, MEA 제작 조건 및 운전 조건을 변수로 하여 임피던스를 측정하고 복소캐패시턴스 분석을 수행하여, 퇴화 경로를 규명하고 운전 조건을 최적화하고자 하였다.

  • PDF

Correction of the hardness measurement for pile-up materials with a nano indentation machine (파일-업 재료에 대한 나노 압입 시험기의 경도 측정값 교정)

  • Park, Moon Shik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.98-106
    • /
    • 2016
  • Measurements of the elastic modulus and hardness using a nano indentation machine rely on the equation for the fitted contact area, which is valid for only sink-in materials. For most soft engineering materials that involve pile-up behavior rather than sink-in, the contact area equation underestimates the contact area and thus overestimates the elastic modulus and hardness. This study proposes a correction method to amend erroneous hardness measurements in pile-up situations. The method is a supplemental derivation to the original hardness measurement with the known value of the elastic modulus. The method was examined for soft engineering metals, Al 6061 T6 and C 12200, via tensile tests, nano indentation tests, impression observations, and finite element analysis. The proposed technique shows reasonable agreement with the analytical results accounting for strain gradient plasticity from a previous study.

Peak Analysis of Gamma-ray and X-ray (감마선 및 엑스선의 피이크 분석)

  • Kim, Seung-Kon;Herr, Young-Hoi;Park, Kwang-June
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.33-42
    • /
    • 1984
  • A great variety of nuclear gamma rays emitted from fission and activation products of spent nuclear fuel contains much information that can be elicited without affecting the integrity of the fuel elements. But the extraction of such information from the complex spectrum is difficult and requires computer codes. In the present work, a versatile code 'CAERI' was developed which locates peaks and calculates their areas for X-rays as well as gamma rays using elegant features of some widely used programs for gamma-ray peak fitting. 'CAERI' coded in FORTRAN used infinite series approximation more accurate than other workers various, simple, piecewise series approximations for evaluations of the Voigt function which represents the X-ray peak with non-negligible natural line width. 'CAERI' can handle even a complex multiplet consisting of peaks from X-rays and gamma rays in arbitrary mixture, which one often encounters in the isotopic analysis of heavy elements such as U and Pu. The results of the fitting performed on the test spectra of $^{177m}\;Lu\;{\gamma}-ray\;and\;^{235}U\;K_{\alpha}$X-ray show good agreement with those by previous workers.

  • PDF

Evaluation of Retrieval Accuracy of NO2 Column Density from Pandora Raw Data According to Wavelength Range and Absorption Cross-section Using DOAS Method (Pandora 원시자료로부터 차등흡수분광법을 이용하여 이산화질소 칼럼 농도 산출 시 파장 구간 및 흡수단면적에 따른 산출 정확도 평가)

  • Kim, Serin;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • In this study, the effect of wavelength range and absorption cross-section used to retrieve nitrogen dioxide (NO2) vertical column density (VCD) from Pandora was analyzed using Differential Optical Absorption Spectroscopy (DOAS). During the GEMS Map of the Air Pollution (GMAP) 2020 campaign, data from direct sunlight observation with Pandora instrument in Seosan was used, and NO2 VCD was retrieved under four conditions. The average NO2 VCD under the four conditions ranged from 1.22×1016~1.38×1016 molec. cm-2, with a maximum difference of 0.16×1016 molec. cm-2 between each condition. The fitting error averaged 3.19~9.59%, showing an error within 10% in all cases, and the RMS was 5.11×10-3~7.16×10-3 molec. cm-2. The retrieved NO2 VCD using 4 conditions shows a slope in the range of 0.98 to 1.09 and correlation of 0.96 to 0.98 in comparison with Pandonia Global Network (PGN).