• Title/Summary/Keyword: 피크 저감

Search Result 60, Processing Time 0.024 seconds

Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program (건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.936-946
    • /
    • 2015
  • This study is aimed to analyze the reduction performance of building energy consumption according to planting base types of panel-type green walls which can be applied to existing buildings. The performance was compared to the general performance of green walls that have demonstrated effects of improving the thermal environment and reducing building energy consumption in urban areas. The number of planting base types was 4 in total, and simulations were conducted to analyze the thermal conductivity, thermal transmittance, and overall building energy consumption rate of each planting base type. The highest thermal conductivity by the planting base type was Case C (0.053W/mK), followed by Case B (0.1W/mK) and Case D (0.17W/mK). According to the results of energy simulation, the most significant reduction of cooling peak load per unit area was Case C (1.19%), followed by Case B (1.14%) and Case D (1.01%) when compared to Case A to which green wall was not applied; and the most significant reduction of heating peak load per unit area was estimated to be Case C (2.38%), followed by Case B (1.82%) and case D (1.50%) when compared to Case A. The amount of yearly cooling and heating energy use per unit area showed 3.04~3.22% of reduction rate. The amount of the 1st energy use showed 5,844 kWh/yr of decrease on average for other types when compared to Case A. The amount of yearly $CO_2$ emission showed 996kg of decrease on average when compared to Case A to which the green wall was not applied. According to the results of energy performance evaluation by planting location, the most efficient energy performance was eastward followed by westward, southward and northward. According to the results of energy performance evaluation by planting location by green wall ratio, it was found that as the ratio of green wall increased, the energy performance displayed better results, showing approx. double reduction rate in energy consumption at 100% of green wall ratio than the reduction rate at 20% to 80% of green wall ratio.

A Case Study on Operation of Energy Management System Connected with Renewable Energy (신재생에너지 연계형 에너지관리장치의 운영 사례 연구)

  • Cho, Jai Young;Ra, In-Ho
    • Smart Media Journal
    • /
    • v.7 no.2
    • /
    • pp.71-77
    • /
    • 2018
  • This paper proposes the components of the energy management system (EMS) for optimum operation of renewable energy and associated energy storage system (ESS), the functions to be considered in designing, the analysis of operational effects, and finally the reduction of electricity costs. To accomplish the objectives, a lithium-ion battery system and an energy management system have installed in a PV system, and it presents the results analyzed with operation data for a year. To increase the system operation efficiency, we propose the effect that EMS is used to replace the demand power at the peak time with the charge power at the light load time, which suggests the influence of contributing to the charge benefit and load leveling according to the ESS tariff.

A Study of Peak Pressure Reduction Control of Electro Hydraulic System using Convolution (컨볼루션을 이용한 전자 유압 시스템의 피크압력 저감 제어 연구)

  • Kim, Kyung Soo;Jeong, Jin Beom;Ryuh, Beom Sahng
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.59-66
    • /
    • 2019
  • Hydraulic systems are essential for most of the construction equipments due to their various advantages, such as very powerful, quick response speed, precision control and remote control. Moreover, they are necessary to apply the electro hydraulic systems for precise and remote controls. Operating the small electronic joystick of the remote controller for the control of a multipurpose work machine with remote control technology increases the possibility of a sudden operation compared to the use of a conventional hydraulic joystick. When a joystick is suddenly operated, the peak pressure is generated in the system due to the quick response of the system. Then a vibration is generated due to the peak pressure, which causes instability to the operation of the construction equipment. Therefore, in this study, we confirmed the level of reduction of peak pressure occurring in the electro hydraulic system by using AMESim, when the output signal of the step shape generated by the sudden operation of the electronic joystick was changed by using the convolution operation.

Evaluation on the Deterioration and Resistance of Cement Matric due to Seawater Attack (시멘트 경화체의 해수침식에 의한 성능저하 및 저항성 평가)

  • 문한영;이승태;김홍삼
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.175-183
    • /
    • 2001
  • Immersion tests with artificial seawater were carried out to investigate the resistance to seawater attack of 5 types of cement matrices. From the results of compressive strength and length change, it was found that blended cement mortars due to mineral admixtures, were superior to portland cement mortars with respect to the resistance to seawater attack. Moreover, XRD analysis indicated that the peak intensity ratio of low heat portland cement(LHC) paste, in portland cement pastes, had better results, and so did that of blended cement Paste. Pore volume of pastes by mercury intrusion porosimetry method demonstrated that total pore volume of ordinary portland cement(OPC) paste had a remarkable increase comparing with that of other pastes. In case of immersion of artificial seawater, the use of ground granulated blast-furnace slag and fly ash, however, showed the beneficial effects of 56% and 32% in reduction of total pore volume, respectively.

A Study on Impact Sound Insulation Properties of EPDM Micro Cellular Pad (에틸렌-프로필렌-디엔 삼원 공중합 (EPDM) 발포체의 충격음 저감 특성에 관한 연구)

  • Lee, Kyung-Won;Lee, Jung-Hee;Sohn, Ho-Soung
    • Elastomers and Composites
    • /
    • v.35 no.2
    • /
    • pp.138-148
    • /
    • 2000
  • In order to investigate the possibility of EPDM micro cellular pad (MCP) as an impact sound insulation product, we studied static/dynamic properties and vibration transfer characteristics of EPDM MCP depending on shape, thickness, degrees of foaming by using material test system (MTS) and lab scale mock-up test apparatus. Static/dynamic rigidity is increased when shape is simple. thickness and degrees of foaming low. We could see that dynamic stiffness is proportional to the transmissibility of EPDM MCP. When dynamic stiffness is increased, characteristic peak at transmissibility curve moves high frequency range or snows increase of maximum value of transmissibility. For lab scale mock-up test and finite element method, EPDM MCP shows low vibration velocity and superior mode shape to just concrete plus slab structure. We could confirm that possibility of EPDM MCP as a impact sound insulation product is high.

  • PDF

A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change (기후변화 대응 저에너지 건축물 조성을 위한 건축물 기화냉각시스템 에너지성능평가 연구)

  • Kwon, Ki-Uk
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • The recent climate change is exacerbating the external thermal environment and increasing the amount of energy used in building. Energy Plus was used to evaluate low energy technology performance of buildings responding to climate change. The test types of basic building(control) and evaporative mist system + basic building(EMS), and the analysis results of each type are compared. Energy performance evaluation result, Cooling peak load were EMS reduction compared to control is about 9%. Annual cooling load per unit area were EMS reduction compared to control is about 17%. Annual energy use per unit area were EMS reduction compared to control is about 10%. Therefore, the effect of the evaporative cooling system is considered to be good through energy reduction technology of building, according to the amount and distance of the evaporative mist system in the future research on building energy performance evaluation should be carried out.

A study on Performance Analysis of COFDM System using PAR Reduction Method (PAR 저감기법을 적용한 COFDM 시스템의 성능분석)

  • Sung Tae-Kyung;Kim Dong-Seek;Cho Hyung-Rae
    • Journal of Navigation and Port Research
    • /
    • v.29 no.3 s.99
    • /
    • pp.245-250
    • /
    • 2005
  • In this paper, considering PAR of transmitter which is pointed out OFDM system's problem, we designed Coded OFDM (COFDM) system and estimated BER and SNR using PAR reduction method In order to evaluate performance, we compared M-ary PSK (M-ary Phase Shift Keying) with M-ary QAM (M-ary Quadrature Amplitude Modulation). In result, performance of 16-PSK and 16-QAM came to good Moreover, 16-QAM showed better performance of about 2 dB in 10-3 error probability and performance of about 5 dB in Peak power clipping than that of 16-PSK.

An Improved PAPR Reduction Using Sub-block Phase Weighting (SPW) Method in OFDM Communication System (OFDM 시스템에서 SPW(Sub-Block Phase Weighting) 기법을 이용한 개선된 PAPR 저감 기법)

  • Kim Sun-Ae;Kang Yeong-Cheol;Suh Jae-Won;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1123-1130
    • /
    • 2005
  • In this paper, we propose an improved side information processing scheme which is important in the sub-block phase weighting(SPW) method for the peak-to-average power ratio(PAPR) reduction. SPW method is to divide the input OFDM subchannels into several subblocks and to multiply phase weighting with each subblocks, properly for the reduction of the peak power. SPW method is similar to the conventional PTS method when the number of sub-carriers, signal modulation format and the number of subblocks are the same. However, unlike the conventional PTS(Partial Transmit Sequence) and SLM(Selected Mapping) method using many stages of IFFT(Inverse Fast Fourier Transform), SPW method only needs one IFFT. Although PAPR can be reduced by SPW method, complex computation burden still remains. In this paper the flipping algorithm and the full iteration algorithm are used f3r the phase control method. Through the computer simulation, we analyze and discuss the properties and the performance of the suggested method.

Reduction of Noise from the Motor Vehicle Horn (자동차 경적소음 저감 방안)

  • 정일록;오수태;서충열;이재인
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.172-178
    • /
    • 1994
  • 본 연구에서는 경음기 본래의 사용 목적인 안전운행을 저해하지 않으면서 사용할 수 잇는 보다 혐오감이 덜한 음질의 경적음을 도출하고자 국내에서 생산, 유통되고 있는 경음기의 현황 파악 및 종류별 경적음의 특성을 분석하고, 이들의 단음과 복합음을 녹음.재생하면서 상호간에 대한 주관적 반응을 설문 조사하여 경음기 1개 장착시 단음 피크치의 음역별 음질과 2개 장착시의 복합음 음질개선을 위한 적정 주파수범위를 도출하고자 하였다. 그리고 자동차 생산공장에 출장하여 차량에 장착된 경음기의 경적음 특성을 분석하여, 그 음량의 크기와 dB(A) 및 dB(C)의 차이와 국내.외 자동차의 경적음에 대한 관리 및 규제 기준을 수집, 분석하여, 소음진동규제법과 한국공업규격에 서로 다르게 규정하고 있는 평가단위를 통일하고자 하였다.

  • PDF

Electric railway power rates inspection program and method to decrease peak energy consumption (전철변전소 전력요금 계산 프로그램 및 피크전력 저감방안)

  • Jeon, Yong-Joo;Ryu, Young-Tae;Park, Ki-Bum;Lee, Tea-Hoon;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1511-1514
    • /
    • 2007
  • KORAIL is one of the biggest consumer in electric power market so it is necessary to investigate power consumption pattern and optimize power rates. This paper presents simulation program for electric power rates define program based on billing system database. Base on the substation annual power usage DB data, the characteristic of the substation power consumption are investigated and effective electrical billing system are compared each other. Through this program it is verified that we can save more then several hundred million won for a year. Also electric train air condition power consumption was measured to figure the method how to reduce peak energy consumption.

  • PDF