• Title/Summary/Keyword: 피복시스템

Search Result 261, Processing Time 0.043 seconds

Uniformity Analysis of Unmanned Aerial Application with Variable Rate Spray System (무인항공 변량방제 시스템의 살포 균일도 분석)

  • Koo, Young Mo;Bae, Yeonghwan
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.111-125
    • /
    • 2018
  • In this study, we evaluated the uniformity of deposition rate and particle size distributions of the variable rate application technique using the unmanned rotorcraft by measuring the spray pattern according to path location in the range of spraying flight. The coefficient of variation (CV) of the lateral coverage rate for the overlapped distribution with the spray swath of 3.6 m in both guidance and auto-pilot flight modes maintaining constant flight speed was about 30% and the CV of the coverage rate by the flight path location was extremely small. Therefore, it was assessed that the variable rate application technology compensating for the variation of ground speed was superior in terms of spray uniformity. In addition, the droplet size distributions in both volume median diameter(VMD) and number median diameter(NMD) were adequate for aerial application and uniform in terms of lateral distribution. Thereafter, we intend to contribute to a precise application on small-scaled fields using the unmanned agricultural rotorcraft by the variable rate application.

Analysis for Steel Corrosion-Induced Damage in Cross-Section of Reinforced Concrete (철근부식에 의한 철근 콘크리트 단면의 손상 해석)

  • Jung-Suk Kim;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.79-88
    • /
    • 2023
  • In this study, a development of the rust formation arising from steel corrosion was modelled to quantify the structural impact in steel reinforced concrete. The interfacial gap, cover depth and diameter of steel rebar were taken for variables in modelling. It was found that the interfacial gap was the most influencing on the structural limit at steel corrosion, followed by steel diameter and cover depth. At 75 mm of cover depth with 20 mm of the steel diameter, the rust amount to reach cracking accounted for 16.95-27.69 ㎛ to 1-10 ㎛ of the interfacial gap. It was found that there was no risk of cracking and structural limit until the rust was formed within the interfacial gap. With a further formation of rust, the concrete section was successively behaved to yielding, cracking and failure. Additionally, the interfacial gap was the most dominant parameter for the rust amount to reach the cracking of concrete at the interfacial zone, whilst the cover depth had a marginal effect on cracking but had a crucial influence on the rust to failure.

Temperature Distribution of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance of Tunnel (터널 내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 발생시 내부온도분포)

  • Won, Jong Pil;Choi, Seok Won;Park, Chan Gi;Park, Hae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.283-290
    • /
    • 2006
  • Concrete has advantages in fire situations as it is non-combustible and has low thermal conductivity. However, concrete that is not designed against fire can experience significant explosive spalling from the build-up of pore pressures and internal tensile stresses when heated. In this study, the performance of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system was evaluated by experimentally and numerically. The fire test was performed in fire resistance(electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von $Stra{\beta}entunneln$) time heating temperature curve, so as to evaluate the temperature distribution with cover thickness of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system. Based on experimental results and numerical analysis, the proper cover thickness of wet-mixed high strength sprayed polymer mortar determined the more than 4cm.

Procuring the Fire Resistance Performance and Structure of Non-Refractory Coating CFT with Using the Corrugate-rib (Corrugate-rib를 활용한 무내화피복 CFT공법의 구조 및 내화성능 확보)

  • Lee, Dong-Oun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.747-754
    • /
    • 2017
  • The Concrete-Filled Tube (CFT) system was developed for its excellent structural performance, such as its good stiffness, stress and ductility, which is derived from the mechanical advantages of its composite structure. However, it is known that the flat type of reinforcing plates need stiffeners placed at a certain distance from each other to avoid buckling failure, which increases the cost accordingly. This paper investigates the contribution of the rib elements placed inside the steel tube for the purpose of increasing the bond strength between the steel and concrete and fire performance with no additional protection. The test results also demonstrate the effectiveness of the corrugated rib's shape against fire. The results of this study showed that the buckling prevention and fire resistance performance criteria were satisfied by the application of the inner surface attachment rib, due to the resulting increase in the strength of the CFT column. Therefore, it is considered that the CFT method using the corrugated rib structure reinforcement developed through this study satisfies the structural and fire resistance performance criteria without the need for a refractory coating. Future studies will be needed to make the process efficient and economical for factory production.

System Design Involved with the MODIS Products generation for the Land Monitoring System of the Korean Peninsula (한반도 국토환경모니터링 시스템을 위한 MODIS Product 생성 및 시스템 설계)

  • Kim, Seung-Yub;Park, Noh-Jun
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.242-245
    • /
    • 2009
  • 본 연구는 한반도 국토 전역을 모니터링 하기 위해 MODIS(Moderate Resolution Imaging Spectroradiometer) 위성영상을 이용하는데 있어서 필요한 기본적 자료처리 및 모니터링 시스템 구축을 목표로 한다. 현재 MODIS관련 product는 대부분 NASA에서 제공하는 알고리즘을 구현하여 제작되며 이러한 product들은 여러 웹싸이트에 접근하여 획득하도록 되어있다. 이러한 방식은 장기적으로 국토를 모니터링 하는데 필요한 자료를 원활하게 공급하지 못하게 되는 단점을 가지고 있다. 그러므로 이 연구는 한반도의 국토환경을 모니터링 하는데 MODIS 자료를 원활히 공급하기 위한 처리 시스템을 구축하고자 한다. 본 연구에서는 Windows환경을 기반으로 사용자 인터페이스를 제공하고 다양한 MODIS 관련 모듈을 내부적으로 자동화 처리하여 보다 쉽게 사용할 수 있도록 개선하였다. 특히 MODIS 원시영상(Production Data Set) Level0 취득부터 보정된 영상자료 Level1B까지의 자동화 처리에 중점을 두었고, Level2이후의 주로 육상(Land)부분에 해당하는 자료를 생성하는 부분을 구현한다. 이러한 MODIS 자료의 생성 이후에 국토 모니터링에 필요한 토지 피복 변화, 산불 탐지 등의 정보를 생성하는 알고리즘 구현 등으로 범위를 확장하려고 한다.

  • PDF

Water Quality Improvement and Restoration Method of Waterside Ecosystem by Mattress/Filter (Mattress/Filter를 이용한 수질개선 및 수변생태계 복원기법)

  • Ko, Jinseok;Park, Kibum;Lee, Seungyun;Jee, Hongkee;Lee, Soontak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1390-1394
    • /
    • 2004
  • 본 연구에서는 하천구조물에서 자연과의 조화를 고려하여 생물과 공생을 목표로 한 다양한 접목시도를 통해서 Mattress/Filter시스템을 이용한 하천 본래의 기능인 환경생태기능을 회복시킬 수 있는 방안을 강구하고, 생태기능이 저하된 하천의 생태계 질을 향상시켜 건전한 하천생태계를 복원시키는 Mattress/Filter의 수질개선시스템의 개발을 시도하였다. 수변생태계 복원을 고려한 Mattress 시스템의 설계는 주위의 경관과 조화를 배려하여 도입을 결정하고, 법면구배 변화점의 모서리가 완만하도록 Mattress의 배치 및 크기를 결정하여 식생에 의한 피복이 가능토록 설계해야 한다. 이 치수 기능을 유지하면서 생태계를 보전하기 위한 대안으로 생태복원구조물인 친환경 Mattress/Filter 의한 수질개선시스템을 개발하여 기존하천에 초본식물들이 식생됨으로써 수질이 개선되어 하천 본래의 생태계를 유지할 수 있는 늪지 조성, 하천의 친수성 확보, 수변식물에 의한 동식물의 서식처 제공 및 수변경관이 보전된 식생 수변공간에 조성에 필요한 기법을 제시하였다.

  • PDF

미래 디지털 환경에서의 병사체계(3)

  • Kim, In-U
    • Defense and Technology
    • /
    • no.9 s.271
    • /
    • pp.50-61
    • /
    • 2001
  • 미래 디지털 전장 환경에서 병사는 하나의 전투체계로 인식되어야 하며 동시에 열상장비, 컴퓨터 및 통신장비 등을 통한 실시간 전투정보 센서로서의 임무 수행이 요구될 것이다. 이러한 요구에 부응하는 새로운 개념의 병사체계는 전투의 주체인 병사의 화기, 피복 및 휴대품 등을 포함한 포괄적인 체계를 말하며 병사의 타격능력, 지휘통제, 생존성, 임무지속성 및 기동성 향상을 위해 각 장비를 시스템화한 것으로 선진 각국 특히 미국과 나토를 중심으로 체계적인 개발이 이루어지고 있으며, 각 국가별로 자국의 요구에 부합하는 병사체계 개발에 노력을 경주하고 있다

  • PDF

농업기술 - 원예재배시설 유동차광 및 냉각기술

  • Kim, Gi-Deok
    • 농업기술회보
    • /
    • v.49 no.6
    • /
    • pp.35-35
    • /
    • 2012
  • 비닐이나 유리로 피복되어 있는 원예재배시설은 저온, 강우 등의 불량환경을 극복하여 작물의 생산성을 높이는 데 크게 이바지해 왔다. 그러나 여름철 고온기에 강광의 유입은 직접적 작물 스트레스는 물론 시설 내 온도를 과도하게 상승시켜 작물생육에 악영향을 미친다. 이 때문에 일반적으로 환기와 차광에 의존하여 시설 내 온도상승을 억제하고 있으나 어려움이 많다. 이에 원예재배시설 내 온도 및 광환경을 개선하기 위하여 개발된 유동차광 냉각시스템을 소개하고자 한다.

  • PDF

A Study of cloud-free MODIS NDVI time series reconstruction using HANTS algorithm (HANTS 알고리즘을 이용한 MODIS NDVI 시계열 영상의 구름화소 문제 해결에 관한 연구)

  • Huh, Yong;Byun, Young-Gi;Kim, Yong-Il;Yu, Ki-Yun
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.169-174
    • /
    • 2007
  • 식생지수 시계열 자료를 이용한 식생 및 토지피복 모니터링을 수행하기 위해서는 구름으로 인한 누락 및 왜곡된 식생지수 문제를 먼저 해결해야만 한다. 특히 한반도와 같이 여름철 집중 호우기에 대부분의 영상에 구름이 존재하는 경우 이들 구름화소를 제거하거나 복원하지 않을 경우, 분석 결과에 상당한 왜곡이 발생하거나 특정 시기의 영상자료를 분석에 반영할 수 없는 경우가 발생하게 된다. HANTS 알고리즘은 이 같은 구름 화소 문제를 해결하기 위한 알고리즘으로 연중 식생지수의 변화는 비교적 단순한 반복적 주기함수의 형태를 가지므로 소수의 cos 함수를 이용한 푸리에 근사식으로 전체 연중 식생지수를 표현할 수 있다는 가정에서 출발한다. 이 때 구름화소로 인한 원식생지수와의 차이가 특정 임계값을 초과하였을 경우 해당 관측치를 근사과정에서 제외함으로써 구름의 영향을 받지 않은 식생지수 시계열 자료만을 이용하게 된다. 이 과정을 수행하기 위해서는 몇몇 제어변수의 설정이 필요한데, 본 연구에서는 한반도와 같이 특정 시기에 장기간 구름이 분포하는 상황에서 최적의 식생지수 복원을 위한 HANTS 알고리즘의 제어변수를 선정하고 재구축된 식생지수를 평가하였다. 이를 위한 실험으로 2002년 대전 지역의 MODIS Terra 식생지수 시계열 영상을 대상으로 HANTS 알고리즘을 주요 식생피복별로 적용해 보았다.

  • PDF

A Study on the Short-Circuit Characteristics of Vinyl Cords Damaged by External Flame (외부화염에 의해 소손된 비닐 코드의 단락 특성에 관한 연구)

  • Choi Chung-Seog;Kim Hyang-Kon;Shong Kil-Mok
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.72-77
    • /
    • 2004
  • In this paper, we studied on the short-circuit process, surface structure, and component variation of vinyl cords. In the results of high speed imaging system (HSIS) analysis, as soon as wire covering was damaged by heat, the conductor of wire came in contact with the other conduct of wire, and the short-circuit occurred. Stereomicroscope and SEM analysis indicated that the source part of wire showed V-type form. The molten beads of load part were bigger than those of source part. In the results of EDX analysis, Cu and O were detected in the source part, whereas covering material (Cl, Ca), Cu and O were detected in the load part. The results will help us to find out the cause of electrical fire.