• Title/Summary/Keyword: 피난 안전성

Search Result 254, Processing Time 0.024 seconds

Koreans' consciousness survey on the onboard safety of domestic passenger ship (국내 여객선 승객의 선박안전 의식조사)

  • Hwang, Kwang-Il;Koo, Jae-Hyeok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.495-501
    • /
    • 2014
  • Users of passenger ships and cruise ships are rapidly increasing year by year, and the needs of the floating architecture are newly come out. But the studies about the passengers' safety and the countermeasures against incidents on board the ships are rare, although the ships' incidents are occurred averagely 15 cases per year during last 10 years. For the purposes of the analysis of the safety consciousness and gathering the some of input data for evacuation simulation for Korean passengers on board ships, this study performed surveys targeting ordinary 394 passengers who are not specially trained and/or accustomed with onboard living conditions. The results are the followings. The reliability on ships' safety is surveyed as 32.3%. Only 14.6% of respondents are aware that there were safety education on board ship during sailing. And 42.2% and 40.9% of respondents answered that they saw the map of emergency routes and knew where the life boats are, respectively. And 73.3% select crews' direct or in-direct(like announcement by indoor broadcasting system) guidances as the most effective evacuation method.

A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility (보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2009
  • Recently, the number of child care facility and social demand for high quality child care service increase suddenly. Especially, social atmosphere about fire safety is more sensitive in Korea. The majority of the residents in a child care facility are composed of early childhood having difficulty to evacuate, and therefore the number of stories of a building and the appropriateness of a evacuation equipment play an important role in the evacuation safety. In this study, problems and improvements for the evacuation safety are dealt with the present conditions of child care facilities, the comparative analysis between domestic and foreign standards, the research on the actual condition of evacuation equipments, and so on. The study brings to a conclusion that it is necessary to systematize the regulations regarding fire safety, to connect fire-fighting facilities for design standards and operations of emergency preparation equipments, to improve the regulations for fire protection system such as the sprinkler system, and to restrict the facilities having fire hazards.

A study on investigation method of The Population Density for Performance-Based Design (성능 기준 도입을 위한 재실자 밀도의 조사 방법에 관한 연구)

  • Kim, Jong-Sung;Hwang, Eun-Kyung;Youn, Ho-Ju;Kim, Jong-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.117-122
    • /
    • 2010
  • 최근 대형화 고층화 복합화 등 점차 발전하는 건축물의 피난 안전성을 확보하기 위하여 성능위주 중심의 피난안전계획이 이루어지고 있다. 그러나 관련 법규의 세부적 기준이 없어 국외 기준에 기반하여 피난안전계획이 진행되고 있다. 이에 본 논문에서는 점차 도입되고 있는 성능적 기준의 도입을 위하여 국내외 관련 기준 및 관련 재실자 밀도 조사 사례를 분석한 결과 국내 제정된 법규는 기준 자체의 목적이 다르고 제한적 용도라는 한계점이 있었으며 또한 기존 연구 사례를 통해 조사 시기 및 방법과 결과의 적용, 신뢰성 확보 등 법규화를 위한 재실자 밀도 기준의 연구 방향을 알 수 있었다.

  • PDF

A Study on Security Plans At Large-Scale International Event Halls: Focusing on Assessment of Escape Safety of K Stadium for The Incheon Asian Games (대규모 국제행사장의 경호경비계획에 관한 연구: 인천 아시안게임 K경기장의 피난안전성 평가를 중심으로)

  • Park, Nam-Kwun;Lee, Young-Ju;Yoon, Myong-O
    • Korean Security Journal
    • /
    • no.30
    • /
    • pp.7-32
    • /
    • 2012
  • Korea faces The 2014 Incheon Asian Games and 2018 Pyungchang Winter Olympics. It is imperative to hold a safe event for the economic benefits, enhancing Korea's image, social integration, national harmony and unity in order to be evaluated as a successful international event. Furthermore, since the international event tends to draw many spectators, the host country must be ready to accommodate a large number of injured people in the event of an accident or terror attack. As stadiums for international events are where a large number of spectators gather in, a large refuge is essential, when dangerous situations happen. In this study, evacuation simulation was conducted using three scenarios in order to predict escape behaviors of spectators during the large escape by destruction of safety systems of stadiums and assess escape safety. As the result, the following results and proposals were extracted. Firstly, it is considered that dangerous situations during the security of stadiums should be predicted in advance and concrete plans for a large refuge of spectators have to be established to minimize damage. Secondly, it was found that the reduction in evacuation exits has an important impact on evacuation in an emergency situation. It implies that securing escape exits are quite important. Thirdly, there were areas where spectators stayed, due to blocked escape exits, while they were dispersed and concentrated at once. It demonstrates that security plans considering properties of facilities are required to solve these problems.

  • PDF

A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses (공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Lee, Doo Hee;Hwang, Hyun Soo;Kim, Hee Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.38-50
    • /
    • 2022
  • Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.

A Case study on the Escape Performance of Apartment Buildings (사례를 통한 공동주택의 피난성능에 관한 연구)

  • 이용재;이범재
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.59-69
    • /
    • 1998
  • As high-rise Apartment buildings increase the importance of fire prevention and escape performance. While these buildings provide dwellers with much more houses, they have the basic escape safety problem in their apartment buildings. In these respect, this study aims to present the Principles of Fire protection for the escape performance of apartment buildings. This study reviews basic theories of escape in apartment buildings. I figure out the characteristics of the fires in apartment buildings by case studying the fire in the apartment buildings, and find out the existing problems for escape performance and fire prevention by surveying. In this study, the major findings are as follows: The planning method should be based on the escape performance. In the planning stage, fire safety should be considered more seriously than law and economic factors.

  • PDF

A Study on Influential Factors of Egress Behavior in Respect of the Fire Prevention Manager in the Large-scale Shopping Mall (대규모 판매시설의 방화관리자의 측면에서 본 피난행동 영향요인에 대한 연구)

  • 박재성;윤명오
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.108-113
    • /
    • 2004
  • Emergency response of fire prevention manager has an effect on decisive emergency exit behavior of customer who is not accustomed to emergency response in a large-scale shopping department on fire. Especially enclosed stairways in a large scale store are usually located in back space where is impossible for customer to access. Therefore, speedy emergency exit inducement by fire prevention manager is needed for the customer's safe egress. The object of study is to analyse the factors affecting egress behavior and emergency response of fire prevention manager in respect of fire prevention management.

A Study on the Safety Evacuation of Onboard Fire (선박화재시 피난 안전성 연구)

  • Kim, Won-Ouk;Kim, Chang-Jae;Chae, Yang-Bum
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.59-60
    • /
    • 2010
  • Unlike cases of fire on land where experienced fireman and various fire fighting equipment are present, onboard fires need to be independently extinguished, making it a complex process. The primal objective of getting quick control of a fire is to prevent casualties which generally occur from inhalation of toxic fumes rather than the fire itself. However, if for some inevitable reason the fire cannot be contained, everyone in that particular area must evacuate to avoid any possible casualties. In this research, through a simulation of the CFD, we will observe the soot density concentration which affects evacuation within an onboard fire in relation to the possible evacuation time to conclude a time zone for a safe exit.

  • PDF

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.

Study of evacuation fire doors in multiple facilities (다중이용시설의 피난방화문에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7380-7384
    • /
    • 2014
  • Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.