• Title/Summary/Keyword: 피난설비

Search Result 151, Processing Time 0.024 seconds

Numerical Study on the Improvement Heat and Smoke Control System in Old Subway Station on Train Fire (수치해석을 통한 노후 지하철 역사 내 열차 화재 시 제연모드 개선에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.88-96
    • /
    • 2017
  • The subway can transport a lot of people at a certain route at once, and the railway and the platform are underground, so it is advantageous to use the ground space efficiently. But If a fire occurs in a subway that is used by an unspecified number of people, such as the Daegu Subway Fire Disaster, many casualties can occur. As a result of the previous research, it was confirmed that the performance of the ventilation system of the old subway platform was remarkably degraded. Therefore, in this study, based on the experimental results of the previous research, we confirmed the flow of the hot and CO flows according to the ventilation mode in the case of fire by three - dimensional numerical analysis. As a result, it was found that the old ventilation system could not maintain the hot air temperature below the reference value for 4 minutes based on the evacuation time of the platform, and when the ventilation performance was enhanced by adding Oversized Exhaust Ports at the upper part of the platform, And the temperature of the heat flow can be maintained.

Evaluation of the Appropriateness of Smoke Control Conditions of Platform at the Subway Fire by using FDS (FDS를 이용한 지하철 객실 화재 시 승강장 제연조건의 적정성 평가)

  • Kim, Ki-Sung;Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.8-14
    • /
    • 2013
  • In the subway, various fires continue to take place across the world. In the Daegu subway accident in 2003, many people were damaged by shortened visibility range caused by toxic gas and smoke. This paper, assuming that a subway fire happens in the Mandeok Station of the subway system in Busan, analyzed different smoke-spreading situations depending on the ventilation situation at its platform (opening of the train doors, operation of ventilation facilities in the tunnel, and working of fire door), using FDS. The calculation proved that it would be more effective to secure evacuation route when the ventilation facilities of the tunnel are not operated, than when they are on. And, it was also found that the case where the doors of the platform to the escape route and only the platform-facing doors of the subway car on fire office are open would be more effective to ventilation than the case where all the doors are open. And, it was found to be important that the fire doors of the platform are working properly.

The Analysis of Correlation Major System Factors with the Performance of Smoke Control Systems Using Pressure Differentials (차압제연설비의 성능과 관련된 시스템 및 환경 변수와의 상관성 분석)

  • Yeo, Yong-Ju;Kim, Hak-Jung;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • The smoke control systems using pressure differentials are already well known as the most reliable method to prevent the smoke infiltration into the emergency stairs or safe spaces. However, it is true that many problems are domestically pointed out due to the insufficient understanding and technology on the smoke control systems using pressure differentials. In this regard, this work analyzed the effect of major factors for smoke control system using pressure differentials such as a duct area, opening area of air supply damper, improvement on open vestibules, stack effect and location of air supply. In conclusion, adequate pressure differentials can not be maintained in small duct because the smaller duct area have the large friction loss. Especially, It is confirmed that the major factor for deterioration of smoke control system performance is stack effect that makes pressure differentials smaller in the lower floors.

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Statistics and Management Systems of Unwanted Domestic and Foreign Fire Alarms (국내·외 비화재보의 통계 및 관리체계에 관한 연구)

  • Hwang, Euy-Hong;Lee, Sung-Eun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.30-40
    • /
    • 2020
  • In the event of a fire and a disaster, prompt and accurate alarms inside and outside the building are directly related to the minimization of damage and the success of life evacuation. However, due to unwanted fire alarms in automated fire detection systems, the number of dispatches by misunderstanding in the 119 service is increasing. This causes the insensitivity to the safety of building managers and the waste of the fire-fighting power. Therefore, in this study, the statistical databases and literature on unwanted fire alarms in Korea and abroad (USA, UK) were identified and the management systems for unwanted fire alarms were compared and analyzed to identify problems of statistics in the management systems for unwanted fire alarms.

A study on the Optimum Capacity of Citadel (선원대피처의 적정규모에 관한 연구)

  • Kim, Won-Ouk;Kim, Chang-Jae;Chae, Yang-Bum
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.142-143
    • /
    • 2011
  • As mentioned above, various safety measures are considered and discussed as hijacking of Korean vessels by pirates is increasing. Thus, the standard for ship's facilities has been partially revised and setting up an evacuation shelter on all vessels sailing dangerous zone has been reinforced. This research aims to discuss crew Citadel set up that has to sail long haul. In addition, measures against potential gas flow have to be taken due to recent pirate armed and portable rocket attacks. There is also a possibility of fire outbreak within the vessel due to its nature. Thus, this research assesses the relevant number of crew Citadel theoretically. It will also make a model by estimating the relevant number of shelters in the event of fire outbreak and implement simulation using FDS.

  • PDF

A Study on the Development of System for Dispatcher (상황실 화재 접수자 중심의 화재상황별 시스템 개발 연구)

  • Choi, Doo-Chan;Ko, Min-Hyeok;Min, Se-Hong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.203-209
    • /
    • 2020
  • Purpose: This study aims to support the dispatcher to analysis the architecture type of fire. Method: Analysis the dispatch protocol guideline (released by gyunggi fire brigade) and make the dispatch scenario by site, combustibles, evacuation, fire extinguish systems. Result: After making scenario, develop the system (for dispatcher), is based on the tablet PC. Conclusion: Dispatch systems apply not only fire but rescue and disaster. This study focus on the fire, but It is need to expend the rescue and disaster. in korea, Fire Safety Evaluation and Multishop DB are possible to link to this system.

A Study for Optimal Evacuation Simulation by Artificial Intelligence Evacuation Guidance Application (인공지능 피난유도설비 적용에 따른 최적 대피시뮬레이션 연구)

  • Jang, Jae-Soon;Kong, Il-Chean;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.118-122
    • /
    • 2013
  • For safe evacuation in the fire disaster, the evacuees must find the exit and evacuate quickly. Especially, if the evacuees don't know the location of the exit, they have to depend on the evacuation guidance system. Because the more smoke spread, the less visibility is decreasing, it is difficult to find the way to the exit by the naked eye. For theses reasons, the evacuation guidance system is highly important. However, the evacuation guidance system without change of direction has the risk that introduce to the dangerous area. In the evacuation safety assessment scenario by the evacuation simulation has the same problem. Because the evacuee in the simulation evacuate by the shortest route to the exit, the simulation result is same like the evacuation without the evacuation guidance system. In this study, it was used with MAS (Multi Agent System)-based simulation program including the evacuation guidance system to implement the change of evacuation by fire. Using this method, confidence of evacuation safety assessment can be increase.

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.