• Title/Summary/Keyword: 피난설비

Search Result 151, Processing Time 0.024 seconds

Analysis of Safety Management Operations of Fire Risk Factors in Small-Scale Construction Sites (소규모 건설현장 화재 위험요인 안전관리 운영실태 분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.775-785
    • /
    • 2022
  • By analyzing the operation status of fire safety management of small construction site workers, deriving problems, and suggesting improvement measures, this study was conducted to present practical basic data for their efficient use in the future, and the following conclusions were drawn. First, it was analyzed that small construction site workers are elderly in the age group of construction workers, have short construction skills, most of the jobs are working in the construction industry, and the employment type is non-regular workers. Second, the fire safety management improvement plan of small construction site workers is systematized, fire safety manager is deployed to manage fire risk, fire escape routes and emergency warning facilities are provided to inform all workers at the construction site. In addition, measures to reduce industrial accidents are needed through realistic evacuation training, fire VR training, and interesting educational programs.

A Study on the Risk Assessment of the Underground Space -The Estimation of Smoke Reservoir Screen for Smoke Control in Subway Station Platform (지하공간의 위험성평가에 관한 연구 -지하철 역사내의 연기제어를 위한 제연경계벽의 효용성 평가)

  • Roh Sam-Kew;Hur Jun-Ho
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.103-109
    • /
    • 2004
  • The risk of underground space become an important issue of life safety thought the Taeku subway line Accident. It is essential to study of smoke control screen to minimize the damage of human life because of smoke passage and passenger evacuation routes are on the same vertical and dispersion movement. The Fire modeling result shows the effect of fire control screen can save the evacuation time about 2-2.5 times compare to existing the system However, The designs of fire control screen need to be complied with smoke control ventilation system to present optimum design and the position of installation.

The Embody of the Direction Escape Algorithm for Optimization Escape (최적 비상대피로 유도를 위한 방향성 유도 알고리즘 구현)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Dong-Woo;Mun, Hyun-Wook;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.115-120
    • /
    • 2009
  • In this parer, we design the artificial intelligent direction escape light control system to improve/complete the defects of the existing fire fighting system, and sketch an optimum escape guide algorithm for its implementation. It intends to minimize human casualties and injuries by calculating/predicting moving line of the optimum emergency escape, by means of interlocking the sensor and the reception group and analyzing the data of the combustion point and the smoke movement. The optimum escape algorithm is designed by FLOYD algorithm which calculates the shortest distance. It consists of the measuring method which calculates the shortest distance by using hazardous factors for each condition in danger which is judged by the sensor installed in each area.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

철근 콘크리트 구조물의 화재조사ㆍ진단방법 및 유지관리방안(일본 콘크리리트공학협회 기준을 중심으로)

  • 권영진;이차돈;홍성걸;신영수;이경구
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.40-46
    • /
    • 2002
  • 산업화 도시화에 따른 건축물의 밀집과 고층화의 환경에서 화재 재해 발생은 인명피해 및 재산피해에 치명적인 결과를 가져올 수 있으며 화재로 인한 인명 및 재산 피해는 두말할 것도 없이 막대한 국가적 손실을 초래한다고 할 수 있다. 따라서 화재발생을 사전에 억제하는 구조물의 방화ㆍ내화구조 및 피난계획, 소화설비 소화활동설비 등에 대한 방재 연구와 더불어 화재발생후 화재의 원인조사와 구조물의 재사용 여부 또는 보강 필요성, 자산의 평가의 과학적인 근거를 위해 신뢰성 있는 안전성 평가에 대한 연구가 필요한 실정이다.(중략)

A Study on the Pressure Difference of Smoke Control Influence Factor in the Super High-rise Building (초고층 건물의 제연영향요소에 따른 수직피난공간 압력분포 시뮬레이션)

  • Choi, Seung-Hyuck;Lee, Dong-Yun;Jun, Hyun-Do;Lee, Dong-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.130-135
    • /
    • 2009
  • These days, the super high-rise buildings construction plans are increased in Korea. But the stack effect in the super high-rise building interrupts the smoke control system's operation because of pressure difference, so it is more dangerous than the general building when firing. Therefore it needs to study about the pressure difference in the super high-rise buildings. We research the smoke control influence factor in the super high-rise building. Reflecting the influence factor, the simulation is practiced the case by case.

  • PDF

A Study on the Fire Resistance Performance Evaluation of Fire Dampers (방화댐퍼의 내화성능평가에 관한 연구)

  • Seo, Hee-Won;Sung, Si-Chang;Choi, Dong-Ho;Kim, Dae-Hoi;Park, Soo-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.90-95
    • /
    • 2010
  • 방화댐퍼는 방화구획을 관통하는 덕트에 설치되어 화염의 전파 및 연소확대를 방지하도록 하는 방화설비로서 '건축물의 피난 방화구조 등의 기준에 관한 규칙'에서 구조 및 시험기준에 대해서 규정하고 있으나, 정해진 성능기준이 없으며 방화설비에 있어 가장 중요한 내화성능에 대해서 언급이 없는 등 개정이 필요하다. 본 연구에서는 방화댐퍼의 'KS F2840(방화댐퍼의 내화시험방법)'시험에 대해서 소개하고, 방화댐퍼의 내화시험 사례를 통해 성능 평가방법으로서의 적용 타당성을 검토하였다.

  • PDF

Field Experiments on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 피난문 개방시 방연풍속 형성특성에 대한 현장실험)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.463-467
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The field experiments on pressure differential systems for smoke management in two high buildings of 20 stories and 21 stories are carried out to evaluate the features of airflow through open door between accommodation and lobby. The procedures and results of experiments are presented.

  • PDF

A Study on Perfomance Based Evacuation Plan for a Large Indoor-Arena (대규모 실내경기장의 성능위주 방재계획에 관한 연구)

  • Choi, Yong-Seok;Kim, Hyung-Keun;Lee, Kyoo-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.687-698
    • /
    • 2011
  • In this study, it was analyzed by a numerical analysis that plan/design considerations for ensuring the spectator safety of large arena audiences in a fire emergency evacuation plan. The latest issue, the 'performance-based design', fire and evacuation plan is important. But nowadays 'Specification-based design' is in common. In evacuation simulation, congestion of exit and aisle is ignored because only evacuation time of large-space is mainly analyzed. In smoke flow,'smoke filling effect' tends to be overrated. From now on, when design a field house, it is needed not 'smoke filling effect' and 'large-space evacuation' analysis, but analyzing 'whole building evacuation time' for ensuring fire evacuation safety of spectator.

Analyses of Scenarios Based on a Leakage of Highly Compressed Air and Fire Anticipated in CAES (Compressed Air Energy Storage) Facility (압축공기에너지저장 시설에서 발생 가능한 압축공기 유출 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.568-576
    • /
    • 2015
  • In this study, scenarios based on the leakage of highly compressed air and fire occurrence turned out to be high risks in an operation stage of CAES facility were constructed and estimated. By combining Bernoulli equation with momentum equation, an expression to calculate an impact force of a jet flow of compressed air was derived. An impact force was found to be proportional to the square of diameter of fracture and the pressure of compressed air. Four types of fire scenarios were composed to evaluate an effects that seasonal change and location of fire source have on the spread behavior of smoke. Smoke from the fire ignited in the vicinity of CAES opening descended more quickly below the limit line of breathing than one from the fire occurred 10 m away from CAES opening, which is expected to occur due to a propagation of wave front of smoke. It was shown that a rate of smoke spread of the winter fire is faster than one of the summer fire and smoke from the winter fire spreads farther than one of the summer fire, which are dependent on the direction of air flow into access opening. Evacuation simulation indicated that the required safe evacuation time(RSET) of the summer and winter fires are 262, 670 s each.