• Title/Summary/Keyword: 피난모델링

Search Result 37, Processing Time 0.023 seconds

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers (성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구)

  • Baek, Sona;Choi, Jun-Ho;Hong, Won-Hwa;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • The Installation, Maintence, and Safety Control of Fire-fighting Systems Act of South Korea regulates that over 30-storey high-rise buildings including underground spaces should vitally perform the Performance-based Design to minimize property damage and personal injury as a fire risk assessment in advance. Therefore a PBD designer such as a fire safety professional engineer evaluate occupant's life safety by a scientific methodology. In order to evaluate the life safety, fire safety designers calculate the Required Safety Egress Time (RSET) which does not have the legal criteria regarding the standard method of calculation yet. So this way has been showing different results depending upon the designer's choice, knowledges and experiences. In this study, RSET calculation methods by six designers respectively were analysed from the thirteen reports of real performance based design projects conducted in Busan for a last five years. In particular, the Response Time calculation methods which have the most powerful effect for figuring the RSET are compared with the other designer's to deduce an error value.

Structure of FDS for Flow Analysis (유동해석을 위한 FDS의 구조)

  • Lee, Ju-Hee;Kim, Dong-Eun;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.270-273
    • /
    • 2012
  • 오픈 소스인 FDS(fire dynamic simulator)는 건물, 터널내의 화재나 연기, 열기류의 거동을 연구하기 위하여 국내외적으로 광범위하게 이용되고 있다. 체계적인 연구와 확장이 가능하도록 소스코드와 프로그램구조, 각종 메뉴얼을 갖추고 있으며 향후 개발 방향을 온라인을 통해서 소스코드와 함께 공개하고 있다. 비압축성 비정상해석을 근간으로 하고 있으며 난류유동을 해석할 수 있도록 DNS와 LES모델을 가지고 있다. 화재, 연소, 스프링클러, 화재 확산 등의 모델링을 제공하고 있다. 이러한 모델을 바탕으로 다양한 시나리오의 재난, 피난에 적용할 수 있다. 향후 이러한 기본 모델을 바탕으로 새로운 재난 시나리오에 따라 새로운 알고리즘의 적용하기 위해서는 FDS 기본적인 구조와 모델, 그리고 한계점을 이해할 필요가 있다. 본 연구에서는 이러한 FDS모델을 더욱 확장하기 위한 일환으로 FDS(V5.5.3)의 기본적인 구조을 파악하고 몇 가지 검증모델(verification)에 적용하였다. 또한 이를 향후 FDS의 소스코드를 확장할 수 있는 근간으로 삼고자 한다.

  • PDF

A Development of BIM Quality Assurance Checklists for Applying Super-tall Buildings (초고층 복합건축물 적용을 위한 개방형 BIM 데이터 품질관리 체크리스트 개발)

  • Kim, In-Han;Cho, Geun-Ha;Choi, Jung-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.371-374
    • /
    • 2011
  • 본 연구는 개방형 BIM 환경의 품질관리 기준 확보를 목적으로 건설 산업의 공통업무분야와 추가적인 세부업무분야에 대한 품질관리 체크리스트를 제안하고자 한다. 공통업무는 일반적인 목적으로 적용 가능한 설계기준, 시설기준, 시공기준으로 대상을 분류하고, 세부업무는 초고층 건축물의 개방형 BIM적용 및 활용 목적에 따라 피난동선 검토, 에너지 분석 검토 측면으로 대상을 분류하여 각 분야 별 체크리스트를 도출하였다. 도출된 체크리스트가 검증을 통해 실무에 적용되면 BIM 모델의 작성 기준 및 지침과 연계되어 요구되는 조건들을 충족시키는 모델링을 유도하며 BIM 모델의 품질향상의 결과를 가져다 줄 것이라 기대한다.

  • PDF

Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers (급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • This paper investigated pressure differentials in the elevator lobby depending on reference pressures of the pressurizing damper using FDS fire modeling. The results showed the temperatures and pressures in the contained fire room with small leak gaps can increase significantly. Setting reference pressure of the pressurizing dampers to 0 Pa can cause reduction of real pressure differentials and air velocity to resist smoke flow. This would cause smoke movement from fire room to elevator lobby which should be safe area for evacuation.

A Study on Perfomance Based Evacuation Plan for a Large Indoor-Arena (대규모 실내경기장의 성능위주 방재계획에 관한 연구)

  • Choi, Yong-Seok;Kim, Hyung-Keun;Lee, Kyoo-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.687-698
    • /
    • 2011
  • In this study, it was analyzed by a numerical analysis that plan/design considerations for ensuring the spectator safety of large arena audiences in a fire emergency evacuation plan. The latest issue, the 'performance-based design', fire and evacuation plan is important. But nowadays 'Specification-based design' is in common. In evacuation simulation, congestion of exit and aisle is ignored because only evacuation time of large-space is mainly analyzed. In smoke flow,'smoke filling effect' tends to be overrated. From now on, when design a field house, it is needed not 'smoke filling effect' and 'large-space evacuation' analysis, but analyzing 'whole building evacuation time' for ensuring fire evacuation safety of spectator.

Intelligent evacuation systems considering bottleneck (병목 현상을 고려한 지능형 대피유도 시스템)

  • Kim, Ryul;Joo, Yang-ick
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.69-70
    • /
    • 2017
  • As the industry develops, the size of buildings and ships are getting bigger and more complicated. In such a complex space, emergency evacuation systems are required because of the possibility of casualties when an accident situation occurs. However, because present systems are composed of basic devices, such as alarms, emergency exit signs, and announcement regarding the situation and inform only the least information to evacuees, evacuees are not able to judge objectively. To solve these problems, various evacuation algorithms have been proposed. However, these studies aim to search evacuation routes based on specific risk factors or to model the effects of bottlenecks in evacuation situations. Therefore, there is a limit to apply to real systems. Therefore, we propose algorithms to search the optimal evacuation route considering various risk factors such as fire and bottleneck in evacuation situations and to be applicable in actual situation in this paper. Performance evaluation using computer simulations showed that the proposed scheme is effective.

  • PDF

Effectiveness of BIM-based Human Behavior Simulation on Architectural Design Education -Focused on Exploration and Evaluation of Barrier-Free and Fire Evacuation Performances- (BIM 기반의 인간행동 시뮬레이션이 건축설계교육에 미치는 효과에 관한 연구 -무장애와 안전 및 피난설계의 성능탐구와 평가를 중심으로-)

  • Hong, Seung-Wan;Park, Ji-Young
    • Journal of KIBIM
    • /
    • v.10 no.4
    • /
    • pp.1-10
    • /
    • 2020
  • While the importance of barrier-free and fire evacuation design is highlighted in architectural design education, systemic analysis, and examination on such performances are still challenging due to methodological lacks. The present study investigates the effectiveness of BIM-based human behavior simulation for architecture major students' analytical examinations to promote barrier-free and fire evacuation performances. To achieve such an aim, quasi-experiments were conducted, which compare 50 students' analysis and examination scores according to the use and non-use of the simulation, and the data were collected via participants' survey and interview. As a result, T-Test and MANOVA analyses indicate that, compared with its non-use counterpart, the use of human behavior simulation better facilitates the students' (1) examination of the physical properties and dimensions for the disabled's accessibility and evacuation, (2) understanding of the bodily capacity and handicap of the disabled, (3) examination on the spatial layouts and locations of exits, (4) understanding on evacuees' urgent behaviors, and (5) responsibility as an architect. Based on previous studies, the reasons of statistical results are interpreted as the explicit observation and analytical measures of multiple numbers of virtual-evacuees and direct-experience from body range of the disabled responding to the populated occupants as what they face in authentic reality.

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.

Primary Fire Behavior of Compounded Multiplex Theater with Various Fire Conditions (조합형 복합상영관에서의 화재조건에 따른 초기화재 거동해석)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.1-6
    • /
    • 2007
  • This paper investigated the fire and smoke behavior in the compounded multiplex theater using FDS with various spacial and boundary conditions to ensure the fire safety of the multiplex. The results showed that more rapid temperature increase and smoke can be induced near the exit door for the lower fire load duo to the horizontal smoke movement. The overuse of fire resistants can generate more smoke while delaying combustion rate, which can give adverse effect to the evacuation. The mal-function of the exhaust fan would obstruct smoke exhaust but also retard the function of sprinkler head.