A Shelter Guidance Control System from the Disaster using the PLC (전력선 통신을 이용한 재해 발생시 피난구 유도 제어장치 시스템)

  • Eom, Ki-Hwan;Hyun, Kyo-Hwan;Kim, Joo-Woong;Jeong, Seong-Boo;Kim, In-Kook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.92-96
    • /
    • 2005
  • We propose a shelter guidance system using the PLC to resolve that a conventional shelter guidance light for underground space has problems. The proposed shelter guidance system is composed of a main control part, a PLC remote control part, a charging part, a sound generation part, a display part, an alarm part and a smoke sensing part. The efficacy of the proposed system is verified by means of experimental. Experimental results are presented that show the effectiveness and the improvement of noise.

  • PDF

A Shelter Guidance System using the PLC Communication (PLC 통신을 이용한 피난구 유도장치 시스템)

  • Lee, Chang-Young;Lee, Kyu-Yun;Lee, Hyun-Kwan;Kim, In-Kook;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.583-586
    • /
    • 2005
  • We propose a shelter guidance system using the PLC communication to resolve that a conventional shelter guidance light for underground space has problems. The proposed shelter guidance system is composed of a main control part, a PLC remote control part, a charging part, a sound generation part, a display part, an alarm part and a smoke sensing part.. The efficacy of the proposed system is verified by means of experimental. Experimental results are presented that show the effectiveness and the improvement of noise.

  • PDF

인간보행에 적합한 피난 유도

  • Kim, Eun
    • 방재와보험
    • /
    • s.107
    • /
    • pp.45-51
    • /
    • 2005
  • 초고층 또는 대형.다중이용 건축물에서 화재 등 재해발생시 대형참사를 예방하기 위하여 대규모 관람장, 지하철역사 등의 바닥면에 설치하는 피난유도표시 설치가 주목 받고 있다. 화염으로 인해 조명과 피난표지의 식별이 곤란하게 되는 경우 피난유도표지는 피난경로를 지속적으로 확인할 수 있는 수단이기 때문이다. 특히 지난 9.11 세계무역센터 테러 당시 , 공포와 암흑 천지의 상황에서 빌딩 내에 설치되어 있던 피난유도표지는 많은 인명을 구하는데 크게 기여하기도 하였다. 축광 피난구 표지는 빛을 축적해 배터리 등의 전기적인 요소로 작동하는 비상조명과 달리 주위환경에 상관없이 작동할 수 있어 유지관리 측면에서 비상조명의 문제점을 보완할 수 있다. 더욱이 피난경로를 따라 이동할 수 있어 피난자가 얻는 심리적 이익도 함께 얻을 수 있는 잇점으로 전망 또한 매우 밝다.

  • PDF

Analysis of Evacuation Route Selection Pattern of Occupant according to Installation Type of Exit Light and Opening/Closing Direction of Door (유도등 설치유형 및 피난구 출입문 개폐방향에 따른 재실자의 피난경로 선택패턴분석)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.28-34
    • /
    • 2019
  • The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.

국내 여객선 거주구역 피난유도 안전디자인에 관한 사례 연구

  • Park, Jin;Lee, Han-Seok;Gang, Yeong-Hun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.307-309
    • /
    • 2018
  • 이 연구에서는 해양 사고 중 인명 사고가 큰 여객선 주요 피난경로와 구역에 사고에 대한 예방과 거주구역 환경 개선 사항을 안전디자인을 통해 제시 한다. 이를 위해 대피를 효과적으로 유도 할 수 있는 디자인 개선사항과 안전 디자인이 피난의 기능을 넘어서 선박 거주구에 배치 되었을 때 심리적 심미적으로 미치는 영향에 관한 연구이다.

  • PDF

A Study on the Awareness of Fire Safety and Evacuation Guide System (화재안전의식 및 피난유도 시스템에 대한 연구)

  • Baek, Eun-Sun;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan;Kim, Sun-Woo
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.45-53
    • /
    • 2010
  • The purpose of this study is to find out the most effective evacuation alarm sound which is the one of the most important element of the evacuation guidance system as a fundamental mechanism to minimize the damages of a fire. In this regard, a survey was conducted against the firefighting officers and the general public with questions about the general awareness of fire and their preference to various kinds of fire alarm sounds. The result showed that 1) even though the awareness of the interviewees on fire was improving while there were in familiar places like homes or works. But, when they were situated in unfamiliar locations, the fire safety awareness could not be deemed to be strong. This in turn calls for the education of the public and improvement of the existing policies for the enhancement of the fire related safety awareness in unfamiliar environments. 2) For the question about the possible time they could survive in a fire or the time required for safe evacuation, it turned out that the interviewees were thinking of the time required for evacuation to be short, which calls for proper actions. 3) When the visibility in a fire situation is highly limited, the most preferred answer for the alarm sound was a female voice, saying "The emergency exit is this way," accompanies with flashing lights of sirens for the emergency evacuation guidance.

Study of evacuation fire doors in multiple facilities (다중이용시설의 피난방화문에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7380-7384
    • /
    • 2014
  • Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.