• 제목/요약/키워드: 플럭스 코어드 아크용접

검색결과 17건 처리시간 0.024초

스테인리스강 용접부의 기계적 성질에 미치는 후열처리의 영향 (The influence of post weld heat treatment on mechanical properties of stainless steel weldment)

  • 한종만;한기형;이은배;허만주;한용섭
    • Journal of Welding and Joining
    • /
    • 제14권3호
    • /
    • pp.75-85
    • /
    • 1996
  • In this paper the influence of postweld heat treatment on mechanical properties of SMAW and FCAW stainless steel weldments was examined and the obtained results are as follows ; (1) The amount of $\delta$-ferrite formed by SMAW and FCAW process decreased with increasing holding temperature and time in post weld heat treatment(PWHT), and it was found that the reduced ferrite was transformed into sigma phase after $800^{circ}C{\times}50hr$ PWHT. This sigma phase, even though it was very small, resulted in brittleness of dissimilar weldment between carbon steel and stainless steel in bending test, however in similar weldment between stainless steel and stainless steel was not occured. (2) The chemical composition of sigma phase was measured to 28-30%Cr, 7-9%Mo, 4-6Ni in 316L weldment, and also 35-37%Cr, 0.9-1.0Mo, 6-8%Ni in 309L weldment by EDS analysis.

  • PDF

SM570TMC 강재의 용접부 특성에 관한 연구 (A Study on the Welding Properties of SM570TMC Steel Plate)

  • 임성우;장인화;정우현
    • 한국강구조학회 논문집
    • /
    • 제18권5호
    • /
    • pp.665-675
    • /
    • 2006
  • 건출물이 고층화되고 장스팬화될 수록 고강도이면서 신뢰성이 우수한 강재의 사용요구가 증대된다. 이러한 이유로 개발된 강재가 SM570TMC 강재이다. 그러나 아직까지는 SM570TMC 강재는 우수한 기계적 성질에도 불구하고, 동급의 타 강재보다 우수하다고 하는 용접성이 검증되지 않은 상태이다. 본 연구에서는 현장 작업조건으로 국산 용접재료 2종류와 일본산 용접재료 1종류에 대해서 SA 및 FCA 용접하여 용접성을 평가하였다.

고능률 GMAW의 용접성에 미치는 보호가스의 영향 (Effect of Shielding Gases on the Weldability of High Efficient GMAW Process)

  • 한기형;한종만;이민우;이은배;한용섭
    • Journal of Welding and Joining
    • /
    • 제13권1호
    • /
    • pp.127-137
    • /
    • 1995
  • The possibility of new GMAW process using economic shielding gases including CO$_{2}$ gas was investigated on the effect of shielding gas on weldabilty. In the optimum welding condition using 600A power source, FCAW process showed low depositions rate, 114 g/min at 300A, but new GMAW using other mixed shielding gases exhibited high deposition rate, 208-224 g/min at 450A. TIME gas, Ar+CO$_{2}$ gas and Ar+CO$_{2}$+O$_{2}$ gas as a shielding gas were able to be used to the very high welding current(450A), moreover TIME gas and Ar+CO$_{2}$ gas showed the highest arc stability among shielding gases studied in this experiments. The weld penetration was performed by axial spray transfer mode of weld droplet. On the basis of workability, weldability and economic point of view, Ar mixture (80%Ar+20%CO$_{2}$) gas was recommended as a shielding gas for the development and application of new GMAW process. This shielding gas showed the low spatter, good weld quality, stable arc and low cost at the region of high welding current.

  • PDF

교량용 강재 박스의 현장 제조시 셀프실드 플럭스코어드 아크용접의 적용 타당성에 대한 연구 (A Feasibility Study on the Application of Self-Shielded Flux Cored Arc Welding Process for the On-Site Steel Bridge Box Fabrication)

  • 황용화;고진현;오세용
    • 한국산학기술학회논문지
    • /
    • 제6권2호
    • /
    • pp.122-128
    • /
    • 2005
  • 본 연구에서는 구조용강 SM520을 사용하여 교량용 박스 제작시 플럭스 코어드 아크용접법에서 가스실드방식과 셀프실드방식의 두 공정으로 제작된 용접부를 건전성, 기계적 성질 및 미세조직에서 비교하였다. 그 결과 두 용접 프로세스에 의해 제작된 용접부들은 매크로 조직 및 비파괴 검사 결과 건전성이 입증되었고, 항복 및 인장강도가 각각 $462{\sim}549\;MPa$$548{\sim}640\;MPa$였고, CVN 충격치는 $-20^{\circ}C$에서 요구값인 40J을 충족하였다. 결과적으로, 고속철도나 고속도로 건설시 사용되는 교량용 SM520강 박스 제조시 고소 및 강풍 조건하에서 용접할 때 셀프실드 아크용접법은 기존의 가스실드 아크 용접법과 비교하여 대등한 용접 특성들을 보였기 때문에 현장 시공시 적용 타당성이 있다고 사료된다.

  • PDF

Flux Cored Arc용접용 아크센서의 개발 및 이를 이용한 용접선 추적에 관한 연구 (A Study on the Development of Arc Sensor for Flux Cored Arc Welding Process and its Application for Seam Tracking)

  • 김수영;이승영;나석주
    • Journal of Welding and Joining
    • /
    • 제10권4호
    • /
    • pp.190-198
    • /
    • 1992
  • Among the variety of welding processes available, the flux cored arc welding is one of the most frequently used process, because of its wide range of application and high productivity. The weld joint tracking is indispensable to improve the flexibility of the arc welding robot application for the flux cored arc welding (FCAW) process. In this study, an arc sensor which utilizes the electrical signal obtained from the welding arc itself was developed for weld joint tracking in FCAW. Because a model of the welding arc in flux cored arc welding was required to develop the arc sensor, a mathematical model was proposed by analysing the welding arc behaviour, and also an experimental model by using the factorial experiment and least square method. For overcoming the fluctuation in the welding current signal during tracking the weld joint, it was fitted to a curve which is inversely proportional to a trace of tip-to-workpiece distance by using the quadratic curve-fitting method.

  • PDF

국산 플럭스 코어드 와이어 용접에서 입열량이 용접부의 미세조직과 인성에 미치는 영향 (A Study on the Effect of Heat Input on the Microstructure and Toughness of Weldments Made by Domestic Flux Cored Wires.)

  • 고진현;국정한
    • Journal of Welding and Joining
    • /
    • 제11권4호
    • /
    • pp.57-69
    • /
    • 1993
  • In the present study, the microstructure and Charpy V notch toughness of multipass $CO_2$ FCA weldment in three different heat inputs(1-3KJ/mm)were investigated. The weldments using two different domestic FCAW wires(AWS E71T-1 and E71T-5 equivalent) in C-Mn steel were chemically analysed. The following conclusions can be inferred. 1. T-1 wire Showed a stable arc transfer, less spatter and harsh, a better bead spreading and easy slag removal, whereas T-5 wire suffered from the arc stability, which tended to increase spatter and produce a more convex bead. 2.The microsturctures of the top beads of the weldments in three different heat inputs consisted of coarse-grained boundary ferrite and Widmanstatten ferrite side plate with increasing heat inputs. The modest fraction of acicular ferrite in the two wire weldments was observed in the 2KJ/mm heat input. 3.The fine-grained reheated zones of both welds consisted of a duplex microstructure of polygonal ferrite and second phases. 4. The basic flux weldment of T-5wires showed a higher Charpy impact property than that of T-1 wires because of a higher fraction of acicular ferrite in the weld microstructure.

  • PDF

플럭스 코어드 아크 용접의 아크현상과 스패터 발생량과의 관계 (Relation between Arc Phenomena and Spattering Ratio of Flux Cored Arc Welding with 100% $CO_2$ Shielding gas)

  • 강성원;엄동석;오은식;유덕상
    • 대한조선학회논문집
    • /
    • 제35권4호
    • /
    • pp.65-75
    • /
    • 1998
  • GMA 용접 중 100% $CO_2$ 가스를 사용하는 $CO_2$ 용접은 경제적이고 고능률적이라는 점 때문에 많이 사용되고 있다. $CO_2$ 용접의 아크현상과 스패터 발생량은 용접용 와이어의 화학성분, 실드가스, 용접조건 등에 영향을 받는다. 특히 용접조건은 용적이행 모드를 결정하기 때문에 스패터 발생량에 커다란 영향을 미친다. 본 연구는 $CO_2$ 용접 재료 중 두 type의 FCW(titania계, semi-metal계)를 이용하여 용접조건을 변화시켜 아크현상과 스패터 발생량을 파악하여 용접부의 품질 평가와 용접조건 설정에 기여코져 한다. 본 연구를 통해, 다음과 같은 결론을 얻을 수 있다. 1) 저전류 영역(140A)의 FCW 모두 22V까지는 전형적이 단락이행이 나타났고, 스패터 발생량의 증가와 저전류 스패터 입도를 대립화하였다. 2) 대전류 영역(320A)의 전형적인 globular이행에서 titania계 FCW가 semi-metal계 FCW보다 아크 안정성이 양호하였다.

  • PDF

기계적 피로결함 시험편 제조 및 결함 크기 평가 (Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size)

  • 홍재근;김우성;손영호;박반욱
    • 비파괴검사학회지
    • /
    • 제23권1호
    • /
    • pp.38-44
    • /
    • 2003
  • 원자력발전소의 안전성등급 기기에 적용되는 비파괴검사는 실제 결함을 실현한 시험편을 사용하여 결함탐지능력을 검증하도록 하는 기량검증이 요구되고 있다. 가동중인 원전에서 발생 가능한 균열으로는 기계적 피로균열, 열 피로균열 및 입계부식균열 등이 있으나 본 연구에서는 기계적 피로균열을 대상으로 하였다. 인장 피로하중을 사용하여 기계적 피로결함을 제조하기 위해서 시험편을 설계하였고 원하는 피로결함 파면의 조도를 얻기 위해서 인가하중의 크기 및 사이클 수를 조절하여 피로결함을 발생시켰다. 발생된 결함에 대한 정확한 크기와 위치에 대한 물리적 정보를 얻은 후에 결함이 설계된 크기와 위치에 존재하도록 기밀용접을 실시하였다. 기밀용접 후 잔여 용접 흠은 가스 텅스텐 아크용접 및 플럭스 코어드 아크용접으로 채워졌다. 최종 완성된 피로결함 시험편을 방사선투과검사 및 초음파탐상검사를 통하여 검사한 결과, 설계된 길이와 깊이로 피로결함이 형성되었음을 확인하였다.

가스메탈아크용접에서 콘택트팁의 마모에 미치는 용접재료의 영향 (Effect of wear of Contact Tips to Welding Consumable for Gas Metal Arc Welding)

  • 김인규
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.860-864
    • /
    • 2012
  • The contact tip is higher the wear of resistance and the longer life are demanded to GMA welding process. In this study, four different contact tips with three different compositions by two wires were evaluated their wear resistance by measuring in every one hour the area of enlarged hole at the exit side during actual wleding. Experimental results clearly showed that the Cr-containing tips strengthened by precipitation hardening have much better resistance to wear than those made by work hardening. In addition, flux cored wire is excellent abrasion resistance test results showed. Based on these results, the domestic industry, the life of the contact tip to know will be used as basic data.