• Title/Summary/Keyword: 플래시 간격

Search Result 12, Processing Time 0.017 seconds

Block Replacement Scheme based on Reuse Interval for Hybrid SSD System (Hybrid SSD 시스템을 위한 재사용 간격 기반 블록 교체 기법)

  • Yoo, Sanghyun;Kim, Kyung Tae;Youn, Hee Yong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.19-27
    • /
    • 2015
  • Due to the advantages of fast read/write operation and low power consumption, SSD(Solid State Drive) is now widely adopted as storage device of smart phone, laptop computer, server, etc. However, the shortcomings of SSD such as limited number of write operations and asymmetric read/write operation lead to the problem of shortened life span of SSD. Therefore, the block replacement policy of SSD used as cache for HDD is very important. The existing solutions for improving the lifespan of SSD including the LARC scheme typically employ the LRU algorithm to manage the SSD blocks, which may increase the miss rate in SSD due to the replacement of frequently used block instead of rarely used block. In this paper we propose a novel block replacement scheme which considers the block reuse interval to effectively handle various data read/write patterns. The proposed scheme replaces the block in SSD based on the recency decided by reuse interval and age along with hit ratio. Computer simulation using workload trace files reveals that the proposed scheme consistently improves the performance and lifespan of SSD by increasing the hit ratio and decreasing the number of write operations compared to the existing schemes including LARC.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.