• Title/Summary/Keyword: 플래시오버

Search Result 72, Processing Time 0.032 seconds

Combustive Properties of Low Density Polyethylene and Ethylene Vinyl Acetate Composites Including Magnesium Hydroxide (저밀도 폴리에틸렌과 에틸렌 비닐 아세테이트에 수산화마그네슘을 첨가한 복합체의 연소성)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.69-75
    • /
    • 2011
  • It was performed to test the combustive properties of low density polyethylene and ethylene vinyl acetate (LDPE-EVA) composite by the addition of magnesium hydroxide. Flame retardant of natural magnesium hydroxide was added to the mixture of LDPE-EVA in 40 to 80 wt% concentration. The composite was compounded to prepare specimen for combustive analysis by cone calorimeter (ISO 5660-1). Comparing with virgin LDPE-EVA, the specimens including the magnesium hydroxide had lower flashover possibility. It is supposed that the combustive properties in the composites decreased due to the endothermic decomposition of magnesium hydroxide. The specimens with magnesium hydroxide showed both the lower total heat release rate (THR) and lower CO production rate than those of virgin polymer. As the magnesium hydroxide content increases, the total smoke release (THR) and smoke extinction area (SEA) decreased.

A Study on the Supply and Perception of Personal Protective Equipments for Fire Fighters (화재진압대원의 개인보호장구 지급 실태 및 인식에 관한 연구)

  • Choi, Jaehyeong;Kim, Woojae;Kang, Shinwook;Kim, Junggon
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • In this study, we surveyed the supply and perception of Personal Protective Equipments for firefighters. As a result, most of the respondents answered that they were paid in accordance with the supply standard, but 12% of the respondents said that there were insufficient equipment. Also, satisfaction with the performance of the equipment is mostly satisfied, but the safety gloves are more than 50% dissatisfied. In summing up the results of the survey, it is urgently necessary to improve the current supply standard, which is determined by the life of PPE, to the replacement period according to the using time or frequency. Also, a new standard should be prepared through the follow - up study.

A Study on the Fire Characteristics of Sandwich Panels by ISO 9705 - Full-scale Room Test (ISO 9705 - Full-scale Room Test 시험방법을 이용한 샌드위치 패널의 화재 특성 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Lee, Jeong-Il
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.39-45
    • /
    • 2009
  • This paper studied on the fire characteristics of sandwich panels by ISO 9705 test (Full-scale room test). A comprehensive fire characteristics of sandwich panel was analyzed by applying the test result to the classification standard according to EN 13501-1 and Eurefic Research Program. Consequently, glass wool foam sandwich panel proved to be A class, incombustible - EPS Foam and incombustible - PUR Foam sandwich panels was class B. Also, EPS foam and PUR foam sandwich panels was class C because of flashover.

Partial Garbage Collection Technique for Improving Write Performance of Log-Structured File Systems (부분 가비지 컬렉션을 이용한 로그 구조 파일시스템의 쓰기 성능 개선)

  • Gwak, Hyunho;Shin, Dongkun
    • Journal of KIISE
    • /
    • v.41 no.12
    • /
    • pp.1026-1034
    • /
    • 2014
  • Recently, flash storages devices have become popular. Log-structured file systems (LFS) are suitable for flash storages since these can provide high write performance by only generating sequential writes to the flash device. However, LFS should perform garbage collections (GC) in order to reclaim obsolete space. Recently, a slack space recycling (SSR) technique was proposed to reduce the GC overhead. However, since SSR generates random writes, write performance can be negatively impacted if the random write performance is significantly lower than sequential write performance of the target device. This paper proposes a partial garbage collection technique that copies only a part of valid blocks in a victim segment in order to increase the size of the contiguous invalid space to be used by SSR. The experiments performed in this study show that the write performance in an SD card improves significantly as a result of the partial GC technique.

2R++: Enhancing 2R FTL to Identify Warm Pages (2R++: Warm Page 식별을 통한 2R FTL 개선)

  • Hyojun, An;Sangwon, Lee
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.12
    • /
    • pp.419-428
    • /
    • 2022
  • Since in-place updates for pages are not allowed in flash memory, all new page writes should be written in an out-of-place manner. The old overwritten pages are invalidated. Such invalidated pages eventually trigger the costly garbage collection process. Since the garbage collection causes numerous read and write operations, it is one of the flash memory's major performance issues. In 2R, it modified the garbage collection algorithm, which applies the I/O characteristics of the On-Line Transaction Process workload to improve the Write Amplification Factor. However, this algorithm has a region pollution problem. Therefore, in this paper, we developed 2R++ that additionally separates pages with long access intervals to solve the region pollution problem. 2R++ introduces an extra bit per block to separate warm pages based on a second chance mechanism. Prevents warm pages from being misidentified as cold pages to solve region pollution problem. We conducted the experiments on TPC-C and Linkbench to make the performance comparison. The experiment showed that 2R++ achieved a Write Amplification Factor improvement of 57.8% and 13.8% compared to 2R, respectively.

An Efficient Data Block Replacement and Rearrangement Technique for Hybrid Hard Disk Drive (하이브리드 하드디스크를 위한 효율적인 데이터 블록 교체 및 재배치 기법)

  • Park, Kwang-Hee;Lee, Geun-Hyung;Kim, Deok-Hwan
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Recently heterogeneous storage system such as hybrid hard disk drive (H-HDD) combining flash memory and magnetic disk is launched, according as the read performance of NAND flash memory is enhanced as similar to that of hard disk drive (HDD) and the power consumption of NAND flash memory is reduced less than that of HDD. However, the read and write operations of NAND flash memory are slower than those of rotational disk. Besides, serious overheads are incurred on CPU and main memory in the case that intensive write requests to flash memory are repeatedly occurred. In this paper, we propose the Least Frequently Used-Hot scheme that replaces the data blocks whose reference frequency of read operation is low and update frequency of write operation is high, and the data flushing scheme that rearranges the data blocks into the multi-zone of the rotation disk. Experimental results show that the execution time of the proposed method is 38% faster than those of conventional LRU and LFU block replacement schemes in I/O performance aspect and the proposed method increases the life span of Non-Volatile Cache 40% higher than those of conventional LRU, LFU, FIFO block replacement schemes.

Reduction Characteristics of AC Flashover Voltage by Combustion Flames under Atmospheric Conditions (대기중 연소화염에 의한 교류 플래시오버전압의 저하 특성)

  • 김인식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.1041-1047
    • /
    • 2001
  • In this paper, reduction characteristics of the ac flashover voltage in the horizontal air gap of sphere-sphere/needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrodes. The voltage and current waveforms were measured, when the flashover is occurred, in order to examine the flashover polarity by flame. The reduction characteristics of ac flashover voltage were discussed with the thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that changed by the corona wind and coulomb\`s force. As the results of an experimental investigation, It was found that the reduction of flashover voltages in sphere-sphere system, in comparison with the no-flame case, are 79.9 [%] for k=0, 82.9 [%] for k=0.5, 87.5 [%] for k=1.0, 85.0 [%] for h=0 [cm], 40.8 [%] for h=5 [cm] and 28.2 [%] for h=9 [cm] when ac voltage is applied.

  • PDF

Asynchronous plural I/O index scan using flash SSD (플래시 SSD를 활용한 비동기 복수 I/O 인덱스 스캔)

  • Park, Ji-Young;Kang, Woon-Hak;Lee, Sang-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1389-1391
    • /
    • 2012
  • 인덱스는 데이터 검색을 빠르게 하기 위하여 사용되며, 많은 데이터를 저장하는 대용량 데이터베이스 시스템은 B+-tree 인덱스를 주로 사용한다. B-tree 인덱스를 사용하여 범위 검색을 수행하는 경우 레코드 각각에 대하여 I/O를 요청함으로써 프로세스가 자주 대기(waiting) 상태가 되어 많은 오버헤드가 발생하였다. 이러한 문제를 해결하고자 본 논문에서 비동기 복수 I/O 인덱스 스캔방법을 제안한다. 비동기 복수 I/O 인덱스 스캔이 최고 6.5배 빠른 성능을 보였다.

A Study on the External Wall Heating Temperature Distribution According to Opening Size in Building (건물의 개구부 크기에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.261-267
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as following: when the experiment was conducted with opening sizes(horizontal length) each at 2,000mm, 1,600mm, and 1,400mm, the flashover occurred at 630 seconds, 505 seconds and 510 seconds, respectively. Also, the total heating time, in proportion to this, came to 815 seconds, 713 seconds and 721 seconds. The maximum heating temperature of the exterior wall by the opening size reached 282.4℃ at 2,000mm, 382.9℃ at 1,600mm, and 423.8℃ at 1,400mm. This represented that as the opening size gets smaller, the heating temperature of the exterior wall by fire spread becomes higher.

Fire Test of Old Type Interiors of Subway Vehicle in ISO 9705 Room (ISO 9708 룸 설비를 이용한 구형 지하철 내장재 화재시험)

  • Lee, Duck-Hee;Park, Won-Hee;Jung, Woo-Sung;Hwang, Jung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.481-487
    • /
    • 2010
  • A room scale fire test was done for interior materials from a subway vehicle installed within an ISO 9705 fire test room. The interior materials are the old ones which were made before the new fire safety guideline of subway vehicles. The output of ignition burner was increased in controlled steps to CEN/TS 45545-1. The objectives of this interior fire test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving subway vehicle interior materials that grow to flashover. Temperatures, heat flux and heat release rate variations verse time of the test are measured. Heat release rate is compared with that of calculated by modified flaming area based summation method. These test results will be used for verification of CFD fire simulation of full subway vehicle.