• Title/Summary/Keyword: 플라스틱 렌즈

Search Result 86, Processing Time 0.021 seconds

A Sunglasses Design to Prevent Snow Blindness at High Altitude (설맹 방지를 위한 고소등반용 선글라스 디자인)

  • Choi, Byung-Jin;Jang, Joon-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.19-22
    • /
    • 2007
  • Recently, the population of people exploring High Mountain trekking or expedition is increasing as an increase in the backpackers. Many accidents occurring at High Mountain above 6,000 m are the results of snow blindness. The damage of cornea and/or retina is direct cause of snow blindness. The UV intensity increases on the hand, along with the altitude caused by decrease in the atmospheric pressure, on the other hand the reflections by bright snow at high mountain area. And it increases approximately 3 times and 4 times higher than the ground level at altitude of 4,000 m and 8,000 m, respectively. The use of sunglasses is more favorable than goggles for the protection of snow blindness at High Mountains. The eye frames that have high mechanical strength and the plastic lenses which can protect UV 100% are recommended. The attachable shielding pads are needed to prevent the incident UV light reflected or scattered from the gap between glasses frame and face. The sunglasses must have flexible and long temples to wind the ears adequately for the prevention of detachment during climbing and it is recommended that the metal frame to be coated with plastics to prevent the eye surroundings from frostbite.

  • PDF

Optical and mechanical properties of Diamond-like Carbon film with variation of carbon ratio (탄소비율에 따른 Diamond-like Carbon film의 광학적 및 기계적 특성)

  • Suh, Young-Kyo;Yun, Deok-Yong;Park, Yong-Seob;Cho, Hyung-Jun;Choi, Won-Seok;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.333-334
    • /
    • 2007
  • Diamond-like carbon (DLC)박막은 높은 경도, 화학적 안정성, 높은 광 투과성을 가지고 있어, 공구강, 광학렌즈 및 플라스틱의 보호 코팅을 위해 응용되어진다. 본 연구에는 DLC 박막은 Silicon을 기반으로 하는 태양전지 반사 반지막으로 응용을 위해, 13.56 MHz RF 플라즈마 화학기상 증착 (RF-PECVD)법을 통해 합성되었다. DLC 합성 시 RF power는 150 W, 메탄 (CH4)가스의 유량은 6%~10% 조절되었다. 합성되어진 DLC 박막의 광학적 특성은 UV spectrometry, Ellipsometry를 사용하여 분석되었고, 경도는 Nano-indenter를 사용하여 측정되었다. 측정 결과 투과도와 굴절률 등의 광학적 특성은 탄소 조성비가 6%정도에서 가장 좋은 결과 값을 얻었으나, 물리적 특성인 경도는 탄소 조성비가 높을수록 증가하는 경향을 보였으며, Si기판과의 접착력은 32N 이상의 높은 값을 나타내었다. 결과로써, DLC 박막은 합성시 적절한 탄소 조성비를 통해 silicon을 기반으로 하는 태양전지 반사방지막으로 응용할 수 있다.

  • PDF

Investigation of the Filling Unbalance and Dimensional Variations in Multi-Cavity Injection Molded Parts (다수 캐비티의 사출성형품에서 충전의 불균형과 성형품 치수 편차의 교찰)

  • Kang, Min-A;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.501-508
    • /
    • 2008
  • Small injection molded articles such as lens and mobile product parts are usually molded in multi-cavity mold. The problem occurring in multi-cavity molding is flow unbalance among the cavities. The flow unbalance affects the dimensions and physical properties of molded articles. First of all, the origin of flow unbalance is geometrical unbalance of the delivery system. However, even the geometry of the delivery system is well balanced, cavity unbalance occurs. This comes from the temperature distributions in the cross-section of runner. Temperature distribution depends upon injection speed because heat generation near runner wall is high at high injection speed. Among the operational conditions, injection speed is the most significant process variable affecting the filling unbalances in multi-cavity injection molding. In this study, experimental study of flow unbalance has been conducted for various injection speeds and materials. Also, the filling unbalances were compared with CAE results. The dimensions and weights of multi-cavity molded parts were examined. The results showed that the filling unbalances vary according to the injection speeds and resins. Subsequently, the unbalanced filling and pressure distribution in the multi-cavity affect the dimensions and physical states of molded parts.

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.

Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident (방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구)

  • Park, Byeong Ryong;Ha, Wi-Ho;Park, Sunhoo;Lee, Jin Kyeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.194-201
    • /
    • 2015
  • We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by $^{137}Cs$ gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity ($R^2$ > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

Changes of Visual Acuity and Ophthalmic Symptoms in Female Workers examining Silver Plating Products (은도금제품 검사실 여성근로자들의 시력변화 및 안증상)

  • Ryu, Seung-Ho;Son, Jeong-Il;Lee, Soo-Jin;Song, Jae-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.567-576
    • /
    • 1997
  • To evaluate the effects of reflected glare on eyes, authors assessed the periodic health examination(1991-1996) & self-administered questionnaire data of a semiconductor producing company. The 13 lead frame(LF) department workers have been exposed to high reflected glare in the process for examining the silver plating products. We compared the data of connector(14) and clerical(12) workers as the non-exposed ones. Among LF department workers, 100% felt their visual acuity worsened(connector:81.8%, clerical:85.7%), and 70% had worn the glasses o. contact lenses(connector : 14.3%, clerical :40%) since working at the company. Major ophthalmic symptoms of the LF workers are asthenopia, tearing, decreased visual acuity, congestion and glare. Decrease of visual acuity by Hahn's line change of the LF workers is significantly high during a 5-year follow-up(p<0.05 by simple regression) compared with connector clerical workers.

  • PDF