• Title/Summary/Keyword: 플라스마(plasma)

Search Result 169, Processing Time 0.024 seconds

Production of Hydrogen-Rich Gas from Methane by a Thermal Plasma Reforming (고온 플라즈마 개질에 의한 메탄으로부터 고농도 수소생산)

  • Kim, Seong-Cheon;Lim, Mun-Sup;Chun, Young-Nam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.362-370
    • /
    • 2006
  • The purpose of this paper was to investigate the reforming characteristics and optimum operating condition of the plasmatron assisted $CH_4$ reforming reaction for the hydrogen-rich gas production. Also, in order to increase the hydrogen production and the methane conversion rate, parametric screening studies were conducted, in which there were the variations of the $CH_4$ flow ratio, $CO_2$ flow ratio, vapor flow ratio, mixing flow ratio and catalyst addition in reactor. High temperature plasma flame was generated by air and arc discharge. The air flow rate and input electric power were fixed 5.1 l/min and 6.4 kW, respectively. When the $CH_4$ flow ratio was 38.5%, the production of hydrogen was maximized and optimal methane conversion rate was 99.2%. Under these optimal conditions, the following synthesis gas concentrations were determined: $H_2$, 45.4%; CO, 6.9%; $CO_2$, 1.5%; and $C_2H_2$, 1.1%. The $H_2/CO$ ratio was 6.6, hydrogen yield was 78.8% and energy conversion rate was 63.6%.

Decomposition of CFC-12($CCl_2F_2$) by Discharge Plasma (방전 플라스마에 의한 CFC-12($CCl_2F_2$)의 분해)

  • 강현춘;우인성;황명환;안형환;이한섭;조정국;강안수
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.93-100
    • /
    • 1999
  • Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocatbon) were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5~50kHz). flow rates (100~1,000mL/min), initial concentrations(100~1,000ppm), electrode materials(W, Cu, Al). electrode thickness(1, 2, 3mm) and reference gases($N_2$, $O_2$, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W. respectively, and that decomposition efficiency decreased with increasing frequency above 20kHz and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3m. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al). Decomposition of CFC-12 in the reference gas of $N_2$ showed the highest efficiency among three reference gases, and then the effect of reference gas on the decomposition efficiency decreased in order of air and $O_2$. The optimum power for the maximum decomposition efficiency was 25.3W for CFC.

  • PDF

Determination of Cd and Pb in Human Blood by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry : International Comparison (동위원소희석 질량분석법에 의한 혈액 중 Cd, Pb 성분의 측정 : 국제공동분석)

  • Park, C.J.;Suh, J.K.;Lee, S.H.
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.145-160
    • /
    • 1996
  • Inorganic analytical laboratory of Korea Research Institute of Standards and Science participated in an interlaboratory comparison program operated by Quebec Toxicology Centre of Canada in 1994 and again in 1995. The objective of this program is to enable participating laboratories to assess reproducibility and accuracy of their analytical results for trace toxic elements in human biological fluids. This laboratory determined Cd and Pb concentrations in 3 levels of human blood samples by isotope dilution inductively coupled plasma mass spectrometry. 0.5mL of blood sample is added to the digestion bomb together with 2mL of nitric acid and enriched spike isotopes and then decomposed in the microwave digestion system. The decomposed sample is diluted to 10mL and nebulized into ICP-MS. The Cd and Pb values reported by all participating laboratories are presented and compared. The values reported by this laboratory are within the acceptable range of target values.

  • PDF

Studies on Analysis of Gallium and Indium in Zinc Ores by Inductively Coupled Plasma Atomic Emission Spectrometry (유도결합 플라즈마 원자방출 분광법에 의한 아연광 중 Ga 및 In의 분석에 관한 연구)

  • Hwang, Youn-Ok;Sim, Sang-Kwon;Sung, Hack-Je;Yang, Myung-Kwon
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.131-139
    • /
    • 1993
  • The separation of gallium and indium from the matrix elements such as zinc and other ions, especially form Fe(III) ion was studied for the determination of trace level of them in zinc ores and zinc blendes by inductively coupled plasma atomic emission spectrometry(ICP-AES). Gallium and indium were extracted from the sample solution with a solvent of tributyl phosphate(TBP). The type and concentration of acid, interferences of other ions, the ratio of aqueous phase to organic phase, TBP concentration, sripping efficiency were optimized for the effective extraction. Gallium and indium were separated from other ions in the 5N hydrochloric acid solution of the samples by the extraction with 100% TBP. In this time, Fe(III) was reduced to Fe(II) with hydroxylamine hydrochloride to prevent its coextraction prior to the main extraxtion. After stripped from organic phase by the back-extraction with 0.02N HCl, they were determined in the aqueous phase by ICP-AES. This method was known to be quantitative from the overall extraction of more than 95%.

  • PDF

Characteristics of Isothermal Analysis and Emulsion Copolymerization of Vinyl Acetate/Alkyl Acrylate (비닐아세테이트/알킬아크릴레이트계 에멀젼 공중합과 등온 열분해 특성)

  • Cho, Dae-Hoon;Choe, Sung-Il;Seul, Soo-Duk
    • Journal of Adhesion and Interface
    • /
    • v.13 no.2
    • /
    • pp.64-72
    • /
    • 2012
  • Vinyl acetate/alkyl acrylate copolymers were prepared by water-born emulsion copolymerization according to the compositional change of vinyl acetate and various alkyl acrylates such as methyl acrylate (MA), ethyl acrylate (EA), and n-butyl acrylate (BA). Ammonium persulfate (APS) was used as an initiator and poly(vinyl alcohol) (PVA) was used as a protective colloid. The significant result was described as follows. The activation energy determined by an isothermal analysis in the temperature region between $100{\sim}200^{\circ}C$ of the copolymer had the order of PVAc/PMA > PVAc/PEA > PVAc/PBA. The peel strengths before and after the plasma treatment were the order of PVAc/PMA > PVAc/PEA > PVAc/PBA.

Various Cathode Design for Cu Emission Line In See-through Hollow Cathode Glow Discharge (st-HCGD) (관통형 속 빈 음극관 글로우 방전에서 다양한 음극관 디자인에 따른 구리방출선 세기 증가에 대한 연구)

  • Woo, Jeong-Soo;Park, Hyun-Kook;Kim, Yong-Seong;Choi, Kyu-Seong;Lee, Sang-Chun
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.4
    • /
    • pp.351-357
    • /
    • 2004
  • We have investigated the intensity of Cu 510.6 nm emission line in see-through hollow cathode glow discharge (st-HCGD) for the development of medical Cu vapor laser. In order to acquire the stable plasma in st-HCGD cell at high current, several factors such as current, the length and the inner diameter of cathode tube, the shape of the tube, and the range of the sputtering range were tested. An optimum condition in our st-HCGD cell was obtained at 600 V, 700 mA, 2.3 Torr of Ar gas (100 SCCM), and 40 mm of tube with 4-11-4 mm type cathode design. Also, it was indirectly observed that temperature in the cell could reach more than $1,000{\circ}C$ since Cu cathode was melt at the current more than 700 mA (melting point of Cu, $1084{\circ}C$).

Direct Determination of Molybdenum in Simulated Nuclear Spent Fuels by Inductively Coupled Plasma Atomic Emission Spectrometry (유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 몰리브덴 분석)

  • Choi, Kwang Soon;Lee, Chang Heon;Park, Soon Dal;Park, Yang Soon;Joe, Kih Soo
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.291-296
    • /
    • 2000
  • The SIMFUEL which composition is similar to PWR nuclear spent fuels was dissolved with a acid digestion bomb. An analytical conditions of ICP-AES for the direct determination of molybdenum in the uranium matrices without separation process were investigated. Based on the effect of uranium on molybdenum intensity. the most optimum wavelengths of molybdenum were found to be 202.030 and 203.844 nm. However, the method of standard additions is applied to overcome the effects of changing background caused by analyzing the sample solutions containing high concentration of uranium and the standard calibration solutions. The relative error of two methods, direct and indirect measurements with cation exchange resin separation procedures, was less than 5%. Therefore it was possible for this procedure to directly measure molybdenum in uranium matrices without separation. And this method was also applied to the determination of several percent of molybdenum in a U-Mo alloy.

  • PDF

Characteristics of Carbon Dioxide Reduction in the Gliding Arc Plasma Discharge (글라이딩 아크 플라즈마 방전에 의한 이산화탄소 저감 특성)

  • Lim, Mun Sup;Kim, Seung Ho;Chun, Young Nam
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.205-209
    • /
    • 2015
  • CCU (Carbon Capture & Utilization) has a potential technology for the reduction and usage of carbon dioxide which is greenhouse gas emitting from a fossil fuel buring. To decompose the carbon dioxide, a three phase gliding arc plasma-catalytic reactor was designed and manufactured. Experiments of carbon dioxide reduction was performed by varying the gas flow rate with feeding the $CO_2$ only as well as the input power, the catalyst type and steam supply with respect to the injection of the mixture of $CO_2$ and $CH_4$. The $CO_2$ decomposition rate was 7.9% and the energy efficiency was $0.0013L/min{\cdot}W$ at a $CO_2$ flow rate of 12 L/min only. Carbon monoxide and oxygen was generated in accordance with the destruction of carbon dioxide. When the injection ratio of $CH_4/CO_2$ reached 1.29, the $CO_2$ destruction and $CH_4$ conversion rates were 37.8% and 56.6% respectively at a power supply of 0.76 kW. During the installation of $NiO/Al_2O_3$ catalyst bed, the $CO_2$ destruction and $CH_4$ conversion rates were 11.5% and 9.9% respectively. The steam supply parameter do not have any significant effects on the carbon dioxide decomposition.

Sonication in the Analysis of Hexavalent Chromium in Welding Fume (초음파 전처리에 의한 용접 흄 중 6가 크롬의 분석)

  • Yoon, Chung-Sik;Paik, Nam-Won;Kim, Jeong-Han;Park, Dong-Uk;Choi, Sang-Jun;Kim, Shin-Bum;Chae, Hyun-Byung
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.447-459
    • /
    • 1999
  • A study was conducted to compare three analytical methods for determination of hexavalent chromium in the welding fume. Precision and accuracy arc documented for colorimetric, ion chromatographic, and inductively coupled plasma-optical emission spectroscopic method. Evidence is presented that welding fume can affect the oxidation of trivalent chromium. A simple sonication extraction method, proposed in this study, instead of hot alkaline extraction has the advantage of minimizing the potential for chromium oxidation.

  • PDF

Analytic study on arsenic content in plastic materials (플라스틱 소재의 비소 함유량 분석에 관한 연구)

  • Lee, Jae-In;Choi, Zel-Ho;Choi, Ki-In;Ko, Byung-Rae;Choi, In-Suk;Cho, Hun-Sik
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.402-409
    • /
    • 2012
  • Quantitative analytical condition for arsenic in plastic materials by the flow injection-hydride generation-inductively coupled plasma-atomic emission spectrometry was studied. The plastic samples were dissolved by wet-acid digestion method and microwave-acid digestion method. The reproducibility and accuracy in this method was verified using of certified reference materials(CRMs) CRM-EC680k and CRM-EC681k. The analyical results agrees with certified value within the range of uncertainty. The results of CRM-EC680k wer 4.1~4.3 mg/kg (certified value $4.1{\pm}0.5$ mg/kg), and the results of CRM-EC681k were 28.9~30.6 mg/kg (certified value $29.1{\pm}1.8$ mg/kg).