• Title/Summary/Keyword: 플라스마(plasma)

Search Result 169, Processing Time 0.025 seconds

THE EFFECT OF PLASMA-TREATED POLYETHYLENE FIBER ON THE FLEXURAL STRENGTH OF COMPOSITE RESIN IN VARIOUS APPLIED PORTIONS (플라스마 처리된 폴리에틸렌 섬유의 적용 부위가 복합 레진의 굴곡 강도에 미치는 영향)

  • Oh, Yong-Jin;Oh, Nam-Shik;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.401-412
    • /
    • 1997
  • There has been many researches aimed at reinforcing the strength of resin, and these have led to the development and use of numerous materials in recent years. A case in point, is the recent development of plasma-treated polyethylene fiber which has been used mainly in fixed provisional restoration to reduce the incidence of fractures. This study aims at assessing whether plasma-treated polyethylene fiber as applied to composite resin is effective in increasing the flexural strength and how applied portions affect this. Twenty-four applied and eight unapplied composite resin bars were fabricated. Twenty-four applied specimens were divided into three groups. Plasma treated polyethylene fiber was applied to the groups each with different portions of composite resin. In the first group, plasma-treated polyethylene fiber was not applied. In the second group, fiber was applied to the compression side of composite resin. Fiber was applied to the tension side in the third group, while fiber was embedded in the tension side of the composite resin in the fourth group. Each specimen was tested by use of a three-point bending strength test with an instron testing machine, and the flexural strength was calculated. The following results were obtained. : 1. Under the conditions of this study, the third and fourth groups demonstrated a statistically greater flexural strength compared to the first and second groups. 2. But there was no statistically significant difference, not only between the first group and the second group, but also between the third group and the fourth group. Taken together, it can be concluded that plasma-treated polyethylene fiber applied to composite resin is an effective method in increasing flexural strength, and the best way of increasing the flexural strength is by application of plasma-treated polyethylene fiber to the tension side, or the embedding of same in composite resin. It must be mentioned however that this test used a static single-load test method. This method determined the maximum stresses that could be tolerated, but this might not be valid where the prediction of clinical failure is concerned. In order therefore to clinically utilize plasma-treated polyethylene fiber to reinforce the composite resin, it is suggested that a further study which considers the various loads be undertaken.

  • PDF

The Optimization of RF Atmospheric Pressure Plasma Treatment Process for Improving the Surface Free Energy of Polymethylmethacrylate (PMMA) (Polymethylmethacrylate (PMMA) 표면개질을 위한 RF 대기압 플라즈마 처리공정의 최적화)

  • Nam, Ki-Chun;Myung, Sung-Woon;Choi, Ho-Suk
    • Journal of Adhesion and Interface
    • /
    • v.6 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • This study investigated the influence of atmospheric plasma factors such as RF power, treatment time, the gap distance between discharge and sample, and the gas flow rate of Ar on the surface property by using the design of experiment (DOE) method. The plasma treatment time (s), plasma power (W), gap distance (mm) between discharge and sample, and flow rate of Ar gas were in order of important factors for changing the surface free energy of PMMA plates. As a result, the most effective factor for improving the surface free energy of PMMA plates is the distance (mm) from discharge glow to sample plate. Because of the interaction between plasma power (W) and treatment time (s), the power dose (J) factor which multiply plasma power (W) by treatment time (s) should be significantly considered. The optimum condition for maximizing the surface free energy of PMMA plate was found at 1500J of power dose. Through XPS and AFM analysis, we also observed the change of chemical composition, surface morphology and roughness before and after plasma treatment. It is considered that the change of surface free energy of PMMA plate with plasma treatment is influenced by the introduction of polar functional group as well as the increase of surface roughness.

  • PDF

Damage mechanism of particle impact in a ${Al_2}}O_3}-TiO_2$plasma coated soda-lime glass (${Al_2}}O_3}-TiO_2$ 플라즈마 코팅된 유리의 입자충격에 의한 손상기구)

  • Suh, Chang-Min;Lee, Moon-Hwan;Hong, Dea-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.529-539
    • /
    • 1998
  • A quantitative study of impact damage of ${Al_2}}O_3}-TiO_2$ plasma coated soda-lime glasses was carried out and compared with that of the uncoated smooth glass specimen. The shape of cracks by the impact of steel ball was observed by stereo-microscope and the decrease of the bending strength due to the impact of steel ball was measured through the 4-point bending test. At the low velocity, cone cracks were occurred. As the impact velocity increases, initial lateral cracks were propagated on the slanting surface of a cone crack, and radial cracks were generated at the crushed site. When the impact velocity of steel ball exceeds the critical velocity, the contact site of specimen was crushed due to plastic deformation and then radial and lateral cracks were largely grown. Crack length of coated specimens was smaller than that of uncoated smooth specimen due to the effect of coating layer on the substrate surface. According to impact velocity, the bending strength of coated specimens had no significant difference, compared with that of the uncoated smooth specimen. But this represents that the bending strength of coated specimens was increased, considering the effect of sand blasting damage which was performed to increase the adhesion force of coating layer.

Effect of Electrode Process Variables in case of Decomposition of $NO_x$ by SPCP (연면방전에 의한 질소산화물의 분해시 전극 공정변수에 대한 영향)

  • 안형환;강현춘
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.543-563
    • /
    • 1999
  • For hazardous air pollutants(HAP) such as NO and $NO_2$ decomposition efficiency, power consumption, and applied voltage were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of HAP with various electric frequencies(5~50 kHz), flow rates(100~1,000 mL/min) initial concentrations(100~1,000 ppm), electrode materials(W, Cu, Al), electrode thickness(1, 2, 3 mm) and number of electrode windings(7, 9, 11) were measured. Experimental results showed that for the frequency of 10 kHz, the highest decomposition efficiency of 94.3% for NO and 84.7% for $NO_2$ were observed at the poser consumptions of 19.8 and 29W respectively and that decomposition efficiency decreased with increasing frequency above 20 kHz. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3mm in this experiment. As the electrode material, decomposition efficiency was in order : tungsten(W), copper(Cu), aluminum(Al).

  • PDF

Determination of Fission Products in Simulated Nuclear Spent Fuels by Cation.Anion Exchange Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometry (양.음이온교환 크로마토그래피와 유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 핵분열생성물 분석)

  • Choi, Kwang Soon;Sohn, Se Chul;Pyo, Hyung Yeol;Suh, Moo Yul;Kim, Do Yang;Park, Yang Soon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.446-452
    • /
    • 2000
  • The simulated nuclear spent fuel (SIMFUEL) containing the platinum group elements which will not be dissolved in a nitric acid was completely dissolved with a acid digestion bomb. The metallic elements separated in the SIMFUEL were measured by inductively coupled plasma atomic emission spectrometry (ICP-AES). Because the peaks of metallic elements were spectrally interfered by uranium spectrum, uranium and metallic elements were separated by cation exchange resin for Mo, Pd, Rh and Ru and by anion exchange resin for Ba, Ce, La, Nd, Rh, Sr, Y and Zr, respectively. The recovery of Mo, Pd, Rh and Ru after separation by cation exchange chromatography found to be 99-103% and anion exchange separation showed 96.5-107% of recovery except Y with the simulated solution whose concentration was similar to the spent nuclear fuel. The relative standard deviation of this method showed 1.3-6.7% in the SIMFUEL whose concentrations of metallic elements were between several $10^2-10^3$ppm.

  • PDF

Determination of trace arsenic in seawater by flow injection-hydride generation inductively coupled plasma mass spectrometry (연속흐름주입-수소화물생성-유도결합플라스마 질량분석장치를 이용한 바닷물표준시료중의 극미량 비소분석방법의 확립)

  • Suh, Jung-Ki
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.316-325
    • /
    • 2008
  • An inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with flow injection-hydride generation system was used for the determination of trace arsenic in seawater sample. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of seawater (CASS-4, NASS-5). The analytical results agreed with certified value within the range of uncertainty. The expanded uncertainties for CASS-4 and NASS-5 in this experiment were ranged from 6.2% to 6.8% obtained from repeated analyses of the CRMs (n=5). The detection limit of $As^+$ (m/z=74.9216) in this method was confirmed about 0.01 ug/kg. Linearity obtained from calibration curve of arsenic was excellent ($R^2=1$). The detection at $As^+$ (m/z=74.9216) and $AsO^+$ (m/z=90.9165) by using oxygen reaction gas in DRC mode was compared. Sensitivity at $AsO^+$ (m/z=90.9165) was decreased about 25-fold, but the analytical results are the same that at $As^+$ (m/z=74.9216).

THE COMPARATIVE STUDY OF THE MICROHARDNESS AND MICROLEAKAGE IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND PLASMA ARC CURING UNITS (가시광선과 플라스마 광선에 의한 복합레진 중합시 미세누출과 미세경도에 관한 연구)

  • Kim, Sang-Bae;Lee, Kwang-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.180-188
    • /
    • 2002
  • Newly developed curing units(plasma arc curing units) operate at relatively high intensity and are claimed to result in optimum properties of composite resin in a short curing time. The purpose of this study was to evaluate the microhardness and microleakage at the resin-tooth interface of two types of composite resins polymerized with visible light and plasma arc curing units. The results from the present study can be summarized as follows 1. Microhardness in each depth was shown to be higher in group AHL than AP3 & AP6. Group ZHL was lower than AP6 at surface(p<0.05) and had no statistically significant difference at 1mm and 2mm(p>0.05). In other depths, group ZHL was higher than ZP3 and ZP6(p<0.05). 2. The incremental reduction in microhardness with depth was shown to be in all group except in surface-1mm of group AHL and $1{\sim}2mm$ of group ZHL(p<0.05). 3. Degree of microleakage in all oops were shown to be higher in gingival margin than occlusal margin but no statistically significant difference(p>0.05). 4. Differences between curing methods in microleakage were shown to be no statistically significant difference(p>0.05). 5. Differences between composite resins in microleakage were shown to be no statistically significant differ once(p>0.05).

  • PDF

A Study of Damage and Contamination on Silicon by Magnetized Inductively Coupled $\textrm{C}_{4}\textrm{F}_{8}$ Plasma Etching of $\textrm{SiO}_2$ (자화된 유도결합형 $\textrm{C}_{4}\textrm{F}_{8}$ 플라즈마를 이용한 $\textrm{SiO}_2$ 건식 식각시 실리콘 표면에 발생하는 손상 및 오염에 관한 연구)

  • Nam, Uk-Jun;Kim, Hyeon-Su;Yun, Jong-Gu;Yeom, Geun-Yeong
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.825-830
    • /
    • 1998
  • 자화된 유도결합형 C4F8 플라즈마로 SiO2를 건식식각시 실리콘 표면에 발생하는 손상과 오염에 대하여 연구하였다. 오염의 분석을 위해서 XPS, SIMS, TEM을 사용하였으며, 손상정도를 측정하기 위해서 HRTEM과 Schottky-diode 구성을 통한 I-V특성 측정을 사용하였다. 유도 결합형 C4F8 플라스마에 0에서 18Gauss까지의 자장이 가해짐에 따라서 실리콘 표면에 생기는 잔류막의 두께가 SiO2식각속도와 선택비의 증가와 함께 증가하였으며, XPS를 통하여 그 조성이 fluorine-rich에서 carbon-rich 한 상태로 변화함을 알 수 있었다. 자장을 가하지 않는 상태에서는 표면에서 $40\AA$부근까지 고밀도의 손상층이 관찰되었으나, 자장을 가함에 따라서 노출된 손상층의 깊이는 깊어지나 그 밀도는 줄어들음을 HRTEM을 통하여 관찰 할 수 있었다. Schottky-diode를 통한 I-V특성곡선의 분석으로 자장이 증가함에 따라서 전기적인 손상이 감소함을 알 수 있었다.

  • PDF

Spatiotemporal Behavior of Excited Xenon Atom Density in Accordance with Xenon Mole Fraction to Neon and Helium in Alternating Current Plasma Display Panels by Laser Absorption Spectroscopy

  • Kim, Yong-Hee;Hong, Young-June;Oh, Phil-Yong;Cho, Guang-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.415-415
    • /
    • 2010
  • 면방전 구조의 AC-PDP는 페닝 혼합 기체 중에서 Xe 플라스마에서 발생되는 VUV (Vacuum Ultra Violet) 에 의해 들뜬 형광체로부터 가시광이 발생된다. Xe 여기종은 828 nm의 공명준위를 거쳐 147 nm의 진공자외선을 방출하며 823 nm의 준안정준위에서 분자선을 거쳐 173 nm의 진공 자외선을 낸다. 이러한 Xe 여기종의 밀도를 측정하기 위해서는 828 nm와 823 nm의 레이저를 외부에서 인위적으로 조사하여 측정하면 IR (Infrared)의 흡수전과 흡수후의 빛의 세기로 Xe 여기종의 밀도 및 분포를 계산할 수 있다. 본 실험에서는 823 nm에 초점을 두었으며 LAS (Laser Absorption Spectroscopy) 기법을 통하여 He-Ne-Xe(15%, 20 %, 30%) 400Torr의 3종 기체의 Xe 함량에 따른 시공간의 Xe($1s_5$) 여기종 밀도 분포와 방전효율을 관측하였다. 최근 3전극 면방전형 AC-PDP 효율 향상을 위해 3종 기체의 Xe함량비의 방전기체에 대한 연구가 수행되고 있다. 이러한 기초 데이터는 혼합기체 조건에 따른 면방전 구조의 3전극 AC-PDP의 발광 효율을 개선하는 데 유용한 자료로 활용될 것이다.

  • PDF

Kinetic and Thermodynamic Analysis of AChE Inhibition of Solvent Extract Fractions from Inonotus obliquus (차가버섯 용매추출분획의 Acetylcholinesterase 저해활성에 대한 동역학 및 열역학적 해석)

  • Kim, Hak-Kyu;Hur, Won;Hong, Eok Kee;Lee, Shin-Young
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.289-296
    • /
    • 2011
  • Twenty four fractions by solvent extraction and/or acid precipitation from fruit body and culture broth of Inonotus obliquus were prepared, and their inhibitory effect against acetylcholinesterase (AChE) was investigated. Among these fractions, acid (1 M HCl) precipitates from cell-free culture broth and fruit body exhibited the highest inhibitory effect on AChE in vitro. Acid precipitates inhibited AChE activity in a concentration-dependant manner and $IC_{50}$ values of both acid precipitates were 0.53 mg/mL. The inhibition pattern was general non-competitive inhibition. The energetic parameters were also determined by dual substrate/temperature design. Both acid precipitates increased the values of Ea, ${\Delta}H,/;{\Delta}G$ and ${\Delta}H^{\ast}$ decreasing the value of ${\Delta}S$ for AChE. The results implied that the acid precipitates from I. obliquus increased the thermodynamic barrier, leading to the breakdown of ES complex and the formation of products as inhibitory mechanism.