• 제목/요약/키워드: 프리캐스트 콘크리트 패널

검색결과 41건 처리시간 0.02초

프리캐스트 콘크리트 대형 패널을 이용한 조립식 아파트 공사 (Prefabricated Apartments Project Using Precast Concrete Large Panel System)

  • 박의식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.49-52
    • /
    • 1989
  • This report introduces the large scale prefabricated apartment project in Saudi Arabia designed and built by Hyundai Engineering and construction Co. as turn-key basis from ministry of Public works and ltousing of Saudi Arabia. This project using precast large panel system is 7,600 dwelling unit, total building area 1.8 mil sguare meters. Large panel system is a kind of industrialized building method which classified as monolithic system, total system and structural system. Hyundai Engineering and Construction Co. develop his own prefabricated large panel system for this project and named "HYUNDAI SYSTEM". The key point of this system is vertical and horizontal joints between panels. Also stability of whole building structure is especially important for this kind of prefabricated building. building.

  • PDF

태양광 도로용 프리캐스트 콘크리트 블록 포장의 현장 적용과 계측 (Field Application and Performance Measurements of Precast Concrete Blocks Developed for Paving Roadways Capable of Solar Power Generation)

  • 김봉균;이병재;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.69-76
    • /
    • 2020
  • 지구온난화는 급격한 기후변화 및 자연재해를 발생시키고 있어 세계에서 가장 중요한 문제로 대두되고 있다. 이에 각국에서는 이산화탄소 배출 저감, 재생에너지 비중 확대 등의 정책을 대폭적으로 추진하면서 재생에너지에 관련된 연구가 활발히 진행되고 있다. 이중 태양광 발전은 기존의 도시 외곽의 유휴부지 뿐만 아니라 BIPV와 같이 도심지 내에 적용연구가 수행되고 있으며, 선진국에서는 도로에 태양광 발전을 적용하기 위한 실증시설 조성이 진행되고 있다. 따라서 본 연구에서는 태양광 발전이 가능한 도로 건설을 위해, 태양광 패널과 프리캐스트 콘크리트 블록을 모듈화 하기 위한 구조요소 설계와 시험시공을 수행하였다. 시공 후 6개월간 현장 적용성 평가를 위하여 미끄럼 저항성 및 블록의 침하량과 단차를 측정하였다. 실험 결과 미끄럼 저항성은 국내 일반도로의 기준은 만족하였으나, 고속도로의 기준은 만족하지 못하는 것으로 나타났으며 시간이 경과함에 따라 미끄럼 저하성이 감소되는 경향을 나타내었다. 또한 블록의 침하량도 점차 미소하게 증가하는 경향을 보여 일부 단차가 발생하는 것으로 확인되었으나 도로의 허용 침하량을 고려하여 볼 때 매우 미소한 것으로 나타났다. 따라서 이후 일정기간 동안 추후 변화양상을 조사 분석함으로서 유지관리 기법의 확립이 요구된다.

폭발 하중을 받는 프리캐스트 프리스트레스트 콘크리트 패널의 거동 평가 (Behavior of Precast Prestressed Concrete Panels subjected to Blast Loading)

  • 강주원;조은선;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제15권1호
    • /
    • pp.95-102
    • /
    • 2015
  • The purpose of this study is to establish and examine the analytical methods based on FEA to predict the behavior of the precast prestressed concrete panels under blast loading. The precast prestressed concrete structures are on the rise, but there is little research in this regard explosion. In this paper, we set the variable to the three models. TNT 500 kg was an explosion in the standoff-distance 3m. In conclusion, the precast models damage was concentrated in the bonded portion. The concrete panels after an explosion occurred continuously deformed. But the including prestressed panels deformation occurs only at the beginning of the explosion were able to see the results.

단면 상세가 변화된 LB-DECK의 균열하중에 대한 실험적 연구 (Experimental Study on the Cracking Loads of LB-DECKs with Varied Cross-Section Details)

  • 윤석구;조규대
    • 콘크리트학회논문집
    • /
    • 제23권5호
    • /
    • pp.657-665
    • /
    • 2011
  • 프리캐스트 콘크리트 페널의 일종인 LB-DECK은 콘크리트 교량 바닥판의 시공시 LB-DECK 위에 현장타설되는 콘크리트와 합성 거동하는 영구 콘크리트 거푸집이다. 현행 LB-DECK은 두께가 60 mm인 콘크리트 슬래브와 슬래브 내부에 높이 125 mm인 lattice-girder들의 일부가 매립되어 있는 구조이다. 이러한 LB-DECK은 시공하중에 의해 종방향 균열이 발생하지 않도록 거더 간격이 충분히 작은 교량 바닥판 시공시 주로 적용되고 있다. 이 논문에서는 최근 강박스 교량과 같이 교량 바닥판의 지간장이 긴 교량에 LB-DECK를 적용할 경우 콘크리트 하부에 발생될 수 있는 종방향 균열을 최소화시키기 위하여, LB-DECK의 균열강도를 평가하기 위한 실험적 연구를 수행하였다. LB-DECK 콘크리트 슬래브의 두께, lattice-girder의 높이, 그리고 top-bar의 지름을 변수로 하는 8종류 24개의 비합성 보부재와 4가지 종류의 합성 보부재 4개를 제작한 후 정적하중 재하실험을 수행하였다. 실험체에 대한 정적하중 재하 실험을 통해 각 실험체의 균열하중과 극한하중을 평가하였으며, 또한 최종 파괴시까지 중앙부 처짐, top-bar의 변형률, 콘크리트 슬래브의 균열 진전 양상 그리고 최종 파괴 형태를 살펴보았다. 각 실험체로부터 얻은 균열하중의 크기는 탄성해석을 통해 얻은 해석치와 비교하였다. 또한 콘크리트 건조수축이 균열강도에 미치는 영향을 파악하기 위하여 AEMM 방법을 이용한 장기 거동 해석을 수행하였다. 실험 결과를 토대로, 지간장이 긴 교량 바닥판에 LB-DECK 적용시, 균열 발생을 예방할 수 있도록 LB-DECK 콘크리트 슬래브의 균열강도와 설계상세를 검토하였다.

PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구 (Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab)

  • 이두성;배정;최헌;민인기
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.465-473
    • /
    • 2013
  • 본 연구에서는 터널에서 발생되는 화재로부터 구조물을 보호하기 위해 내화패널이 부착된 프리캐스트 PSC 슬래브의 내화성능을 조사하기 위해 내화실험이 수행되었다. 내화실험은 독일의 RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) 화재시간-온도곡선을 적용하여 내화성능을 평가하는 것으로 하였다. ITA(2004)에서 제시하는 기준에 따라 내화성능 시험을 수행한 결과, 콘크리트의 손상을 판단하는 위치인 t=0mm의 최대온도는 $367^{\circ}C$로서 손상한계온도 $380^{\circ}C$(ITA 2004)이하였으며, 철근의 손상을 판단하는 위치인 t=25mm의 최대온도는 $239^{\circ}C$로서 손상 한계온도인 $250^{\circ}C$이하로 나타났다. 실험결과로부터, 25mm두께의 내화패널이 부착된 프리스트레스 슬래브 시험체는 내화성능을 가진 것으로 입증되었다.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

균열방지 슬리브가 매설된 패널식 옹벽 (Concrete-Panel Retaining Wall anti-crack sleeve inserted)

  • 장성호;정지승
    • 문화기술의 융합
    • /
    • 제5권3호
    • /
    • pp.345-349
    • /
    • 2019
  • 우리나라는 산지가 70% 이상으로 도로, 철도, 산업단지 조성 등의 기반시설 구축시 원지반 일부를 깍아 부지를 형성하는 이른바 깍기 비탈면이 널리 쓰이고 있다. 최근에는 환경 훼손에 대한 규제가 더욱 엄격해져 대규모 깍기 비탈면을 지양하고 최소한의 용지사용으로 목적구조물을 건설하기 위하여 다양한 방법의 공법들이 개발되어 적용되고 있으며, 그 중 활발하게 적용되는 공법이 패널식 옹벽 공법이다. 패널식 옹벽은 지보재 보강을 통한 원지반의 전단강도 증가와 그 지보재 전면에 프리캐스트 옹벽을 체결하여 벽체를 형성시킴으로써 수평토압에 저항하는 공법이다. 지보재는 쏘일네일링, 어스볼트, 그라운드앵커 등이 사용되고 있으며, 그 중 그라운드앵커는 강선에 미리 인장하중을 도입하는 보다 적극적인 보강형태로 전면판인 패널에 큰 집중하중이 작용하게 된다. 이러한 집중하중은 콘크리트 패널에 균열을 발생시키고 옹벽 자체의 내구성을 저해시키는 요인으로 본 연구에서는 이러한 기존 패널식 옹벽의 단점을 보완하기 위하여 패널 정착부에 강관 슬리브 및 보강재를 매입함으로써 균열을 방지하고, 패널 단부에 요철 모양의 전단키를 적용하여 기존 그라우트앵커가 가지는 개별거동에 대한 취약점을 보완하여 안정성을 향상시켰으며, 옹벽 전면 콘크리트 노출 및 정착부 돌출에 의한 경관성 저하문제를 자연석 문양 연출과 정착부를 돌출시키지 않는 단면구성으로 해결하였다. 패널에 사용된 균열방지 슬리브 및 보강재의 효과를 검증하기 위하여 실내시험 및 3차원 수치해석을 수행한 결과, 강관슬리브 및 보강재의 사용으로 패널의 전반적인 강도 증가와 균열억제 효과가 입증되었다.

FRP-콘크리트 합성 바닥판의 사장교 적용 (Application of FRP-Concrete Composite Deck to Cable Stayed Bridge)

  • 조근희;박성용;김성태;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.217-220
    • /
    • 2008
  • FRP-콘크리트 합성 바닥판을 개선하여 사장교에 경제적으로 적용 가능한 바닥판을 개발하고, 이의 설계 및 경제성 등을 제시한다. 기존의 FRP-콘크리트 합성 바닥판은 탄성계수가 낮은 GFRP 패널의 채용으로 인하여 낮은 단면 강성을 갖게 되는데, 이는 바닥판의 처짐 등과 같은 사용성 문제를 야기할 수 있다. 그래서 기존 FRP-콘크리트 합성 바닥판의 양단을 콘크리트로 감싸서 순지간이 줄어드는 효과를 얻을 수 있는 프리캐스트 FRP-콘크리트 바닥판을 고안하였다. 이 바닥판은 기존 바닥판에 비해 바닥판 지간은 늘어나면서 자중은 크게 늘지 않는 장점을 가진다. 이러한 개선된 바닥판에 대해 거더와 합성하는 경우, 거더 위에서 단순지지하는 경우로 나누어 단면 최적화를 수행하였다. 최적화된 바닥판을 중앙지간 540m인 사장교에 적용한 결과, 상부구조 및 케이블 물량의 감소 효과를 얻을 수 있어 경제적으로 적용될 수 있음을 확인하였다.

  • PDF

복합소재를 활용한 곡면 패널 축소형 실험체의 구조 성능 평가 (An Experimental Study on the Behavior of Small Scale Curved Panel Using Composite Materials)

  • 박희범;박종섭;강재윤;정우태
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2018
  • 국내외에서는 $CO_2$ 저감 및 에너지 효율 증대에 관심의 초점이 되고 있으며 건설 분야 에서도 저탄소 녹색 성장을 위한 노력이 급증하고 있는 실정이다. 특히 FRP는 경량, 고강도, 고내구성 특성을 보유한 신소재로서 최근 국내외에서 제3의 건설소재로 대두되고 있다. 그러나 아직까지 터널이나 아치형 교량 등에 활용가능한 곡면형 FRP 건설자재에 대한 연구는 거의 이루어지지 않고 있으며 현재까지 곡면 구조재에 대한 연구는 프리캐스트 콘크리트에 대한 연구가 주를 이루고 있는 실정이다. 복합소재 패널 축소실험체는 실대형 실험체에 비하여 크기가 작기 때문에 다양한 실험을 수행 할 수 있다. 따라서 본 연구에서는 FRP 부재로만 구성된 중공형, FRP 부재에 콘크리트를 채운 단일 중실형과, 길이방향 연결부를 가지는 연결부 중실형, 그리고 FRP 부재와 콘크리트간의 부착력을 향상시킨 규사코팅 중실형에 대하여 실험을 수행하였다. 실험결과 길이 방향 연결부를 이용하여 복합소재 곡면패널을 결합할 경우에도 단일 부재와 거의 동등한 성능을 보인다고 판단된다. 하지만 실험체의 파괴시 가장 취약한 연결부에서 우선 파괴가 발생하기 때문에 향후 연결부 보강이 필요하다고 판단된다.

해상 프리캐스트 콘크리트 부유체 모듈 가접합을 위한 마이크로 실리카 혼입 수중용 에폭시 접합 성능 검토 : Part 1 - 재료 개발 및 성능 검토 (Micro-silica Mixed Aqua-epoxy for Concrete Module Connection in Water : Part 1 - Material Development and Evaluation)

  • 최진원;김영준;유영준;권성준;김장호
    • 콘크리트학회논문집
    • /
    • 제27권1호
    • /
    • pp.21-28
    • /
    • 2015
  • 최근에 콘크리트 모듈로 건설하는 부유 구조물에 대한 연구가 활발히 이루어짐에 따라 콘크리트 모듈 간 접합 공법에 대한 필요성이 대두되고 있다. 모듈 간 접합 작업은 수중에서 프리스트레싱 텐던을 긴장하여 이루어지므로 시공성이 저하될 가능성이 있어서 가접합을 위한 부착재료 개발이 요구된다. 이번 연구에서는 콘크리트 구조물 보수보강용 섬유보강 패널 부착에 사용된 수중용 에폭시에 $SiO_2$ 계열 마이크로 실리카(Micro-silica : MS)를 혼입하여 콘크리트 모듈 가접합용 접합재료를 개발, 평가하였다. 기존 수중용 에폭시에 0~4% MS를 혼입하여 부착성능 평가를 통하여 최적 MS 혼입량을 산정하였으며 수중용 에폭시의 점도에 따른 MS 혼입 효과를 확인하기 위하여 주제 비율을 각각 0, ${\pm}5$%, ${\pm}10%$로 조정하여 재료성능을 검토한 후 최적 비율을 도출하였다. 도출된 마이크로 실리카 수중용 에폭시(MSAE)의 콘크리트 모듈 접합 성능을 검증하기 위하여 콘크리트 모듈 접합 시험체에 3점 재하 실험을 실시한 결과 MSAE는 기존 수중용 에폭시에 비해 콘크리트 모듈 접합 성능이 크게 향상된 것으로 나타났다.