• Title/Summary/Keyword: 프렛팅

Search Result 2, Processing Time 0.022 seconds

Reappearance of the Electrical Poor Contact in Connectors by Fretting Wear (프렛팅 마모에 의한 커넥터 단자의 접촉불량 재현)

  • Kim, Seong-Woo;Jung, Won-Wook;Wei, Shin-Hwan;Kim, Hyung-Min;Park, Sung-Bae;Lee, Dong-Hun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1361-1366
    • /
    • 2008
  • Failure mechanism of the poor contact is analyzed on the basis of used connectors and this poor contact of connectors is reappeared by the new forced fretting wear method. As the result of failure analysis and reappearance, fretting wear and corrosion of the contact interface causes the contact resistance degradation and the poor contact of connectors. The amount of degradation depends on the fretting stroke. Changes in contact resistance of static contacts are likely to be small and gradual, while motions of contact interface may result in larger and discontinuous changes in resistance and voltage. This voltage drop by fretting motions is large enough to cause the distortion of sensor signal and mis-working of electric components.

  • PDF

A Study for Improvement of Cornering Fatigue Test by Eliminating a Fretting Effect on Steel Wheel to enhance Durability and Reliability (스틸 휠 굽힘 모멘트 내구시험의 내구신뢰성 개선에 대한 연구 - 스틸 휠 접촉면의 프랫팅 제거 -)

  • Chung, Soo-Sik;Jung, Won-Wook;Yoo, Yeon-Sang;Kang, Woo-Jong;Kim, Dae-Sung;Kwon, Il-Ki
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1326-1330
    • /
    • 2008
  • The failure mode of steel road wheels in a vehicle is cracks from ventilation hole through to contact plane on steel wheel's disc plate. But a number of cracks of Cornering Fatigue Limit Test is on contact plane near to wheel nut mounting area, even though it's satisfied with specified cycles. So this paper searches out causes to improve durability and reliability of C.F.T by uni-axial bending moment test. The verified cause is a "fretting" on contact area of steel wheel. In result, this paper suggests a solution to prevent a fretting by inserting a damping shim, 0.7mm between steel wheel contact areas. Therefore this paper makes it possible to move crack position of C.F.T in steel wheel from contact plane to vehicle's failure mode.

  • PDF