• Title/Summary/Keyword: 풍 하중

Search Result 400, Processing Time 0.024 seconds

Characteristics of the Newly Developed Rain Shelter for Grapevine and Growth of 'Campbell Early' (신개발 포도 비가림 시설의 특성과 '캠벌얼리'의 생육)

  • Lee, Yun Sang;Kim, Seung Deok;Lee, Seok Ho;Hong, Seong Taek;Lee, Jae Wung;Hong, Eui Yon;Kim, Dae Il
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.252-257
    • /
    • 2015
  • Fruit cracking and vine leaf spot of grapes tend to occur when the plants were directly exposed to rain under outdoor culture. Rain shelter facility can be an alternative method to prevent the cracking and disease of grape, but it also has some limitations in practical usages. We designed rain shelter facility which can completely shut out the rain and ventilate naturally, and it was upgraded to meet the standards of disaster prevention against snow and wind load. The newly developed rain shelter has two-story roof structure, and the $2^{nd}$ floor roof was equipped over $1^{st}$ floor roof at a distance of 40cm. For natural ventilation and water proof, the upper roof protruded about 50cm from the ridge of a $1^{st}$ floor roof. The various tests were carried to examine such as grape quality, brown spot and fruit cracking of Campbell Early under the conventional and the newly developed rain shelter facility which was built about $100{\ss}{\check{S}}$. In comparison of temperature between the conventional and the newly developed rain shelter facility when outside temperature was more than $34^{\circ}C$, the inside temperature was recorded as $40.7^{\circ}C$ and $37.4^{\circ}C$, respectively. There was no significant difference between the two facilities when outside was below $32^{\circ}C$ The quality such as soluble solids and marketable fruit was increased, and fruit cracking of grapes and vine leaf spot also drastically diminished in the newly developed rain shelter.

Experimental Investigation of the Drag Coefficient of Porous Road Signs (유공형 도로표지의 항력계수에 대한 실험적 연구)

  • Sung, Hongki;Chong, Kyusoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.71-76
    • /
    • 2018
  • Recently, various technologies have been developed for road facilities to reduce the load, some of which use technologies employing perforated plates for wind load reduction. Currently, there are no regulations concerning the drag coefficient of perforated plates for domestic road facilities. In the United States, the regulations regarding the drag coefficient of perforated plates in the 'Minimum design loads for buildings and other structures' were revised based on the studies of Letchford (2001) and Giannoulis (2012). In this study, a wind tunnel test was carried out to analyze the feasibility of applying regulations involving the perforated plates' drag coefficient. The results of the wind tunnel test and the drag coefficient used in the regulation were compared and analyzed. In addition, the reduction effect of the cross area of road signs calculated by applying the drag coefficient was analyzed. The results of the wind tunnel test and the value of the drag coefficient used in the regulation in the US were found to be very similar. Therefore, it was found that it is possible to apply the formula involving the drag coefficient of the perforated plate to the regulation and that the cross area of the perforated plate used for the post of the road sign is reduced by about 9.45% and that of the horizontal post by about 6.45%.

Seismic Response Analysis and Performance Evaluation of Wind-Designed Concentrically Braced Steel Highrise Buildings under Moderate Seismicity (중진대의 지진환경하에서 내풍설계된 초고층 철골조 중심가새골조의 지진응답해석 및 내진성능평가)

  • Lee, Cheol-Ho;Kim, Seon-Woong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.33-42
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall builidng, the probable structural impact of the 500-year design basis earthquake (DBE) or the 2400-year maximum credible earthquake (MCE) on the selected structural system should be considered at least in finalizing the design. In this study, seismic performance evaluation was conducted for concentrically braced steel highrise buildings that were only designed for wind by following the assumed domestic design practice. It was found that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seimsic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. The strength demand-to-strength capacity study based on the response spectrum analysis revealed that, due to the system overstrength factors mentioned above, wind-designed concentrically braced steel highrise buildings having a slenderness ratio of larger than six can withstand elastically even the maximum credible earthquake at the performance level of immediate occupancy.

Analysis of the Structural Safety in a Non-heating Greenhouse with a Single Cover for Citrus Cultivation in Jeju (제주지역 감귤재배용 단일피복 무가온하우스의 구조안전성 분석)

  • Yum Sung Hyun;Kim Hak Joo;Chun Hee;Lee Si Young;Kang Yun Im;Kim Young Hyo;Kim Yong Ho
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.166-173
    • /
    • 2005
  • This study was carried out to evaluate the structural stability in a non-heating greenhouse with a single cover for Citrus cultivation which was built up in Jeju on the basis of the drawing designed by Jejudo Agricultural Research & Extension Services and also to make use of the data for developing a standardized non-heating greenhouse in Jeju. The analysis of a structural stability was conducted by using CFX-5.7 and ANSYS under the design condition of a maximum accumulated snow-depth of 19.1 cm as well as an instantaneous maximum wind velocity of $36.6\;m{\cdot}s^{-1}$ which was set up on the basis of meteorological statistics in Jeju. As a result, the maximum von-Mises stress applied on pipes under the wind velocity of $36.6\;m{\cdot}s^{-1}$ showed a value of $250\;N{\cdot}mm^{-2}$ which was greater than the allowable stress of the pipe with a value of $235.4\;N{\cdot}mm^{-2}$ (=$2,400\;kg{\cdot}cm^{-2}$) and also $53.8\;N{\cdot}mm^{-2}$ under the snow-depth of 19.1 cm, respectively. This result suggested that the greenhouse be unstable under the design condition of an instantaneous wind velocity of $36.6\;m{\cdot}s^{-1}$ so that it was necessary for the greenhouse to be reinforced to secure the structural stability.

Structural Design and Analysis of a Hydraulic Coiling Arm for Offshore Wind-turbine Submarine Cable (해상풍력 해저케이블 하역용 유압식 코일링 암 구조설계 및 해석)

  • Kim, Myung-Hwan;Kim, Dong-Hyun;Oh, Min-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Structural design and analysis of a coiling arm unloading machine for submarine cable have been originally conducted in this study. Three-dimensional CAD modeling process is practically applied for the structural design in detail. Finite element method(FEM) and multi-body dynamics(MBD) analyses are also used to verify the safety and required motions of the designed coiling arm structure. The effective moving functions of the designed coiling arm with respect to rotational and radial motions are achieved by adopting bearing-roller mechanical parts and hydraulic system. Critical design loading conditions due to its self weight, carrying cables, offshore wind, and hydraulic system over operation conditions are considered for the present structural analyses. In addition, possible inclined ground conditions for the installation of the designed coiling arm are also considered to verify overturn stability. The present hydraulic type coiling arm system is originally designed and developed in this study. The developed coiling arm has been installed at a harbor, successfully tested its operational functions, and finished practical unloading mission of the submarine cable.

Structural Performance Evaluation of a Multi-span Greenhouse with Venlo-type Roof According to Bracing Installation (가새 설치에 따른 벤로형 지붕 연동온실의 구조성능 평가)

  • Shin, Hyun Ho;Choi, Man Kwon;Cho, Myeong Whan;Kim, Jin Hyun;Seo, Tae Cheol;Lee, Choung Kuen;Kim, Seung Yu
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.438-443
    • /
    • 2022
  • In this study, the lateral loading test was performed to analyze structural performance of multi-span plastic greenhouse through full-scale experiment and numerical analysis. In order to analyze the lateral stiffness and stress, we installed 9 displacement sensors and 19 strain gauge sensors on the specimen, respectively, and load of l mm per minute was applied until the specimen failure. In the comparison between the full-scale experiment and the structural analysis results of a multi-span greenhouse with venlo-type roof according to bracing installation, there was a large difference in the lateral stiffness of the structure. By installing a brace system, the lateral stiffness measured near the side elevation of the specimen increased by up 44%. As the bracing joint used in the field did not secure sufficient rigidity, the external force could not be transmitted to the entire structure properly. Therefore, it is necessary to establish a bracing construction method and design standards in order for a greenhouse to which bracing applied to have sufficient performance.

Automated Finite Element Analyses for Structural Integrated Systems (통합 구조 시스템의 유한요소해석 자동화)

  • Chongyul Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • An automated dynamic structural analysis module stands as a crucial element within a structural integrated mitigation system. This module must deliver prompt real-time responses to enable timely actions, such as evacuation or warnings, in response to the severity posed by the structural system. The finite element method, a widely adopted approximate structural analysis approach globally, owes its popularity in part to its user-friendly nature. However, the computational efficiency and accuracy of results depend on the user-provided finite element mesh, with the number of elements and their quality playing pivotal roles. This paper introduces a computationally efficient adaptive mesh generation scheme that optimally combines the h-method of node movement and the r-method of element division for mesh refinement. Adaptive mesh generation schemes automatically create finite element meshes, and in this case, representative strain values for a given mesh are employed for error estimates. When applied to dynamic problems analyzed in the time domain, meshes need to be modified at each time step, considering a few hundred or thousand steps. The algorithm's specifics are demonstrated through a standard cantilever beam example subjected to a concentrated load at the free end. Additionally, a portal frame example showcases the generation of various robust meshes. These examples illustrate the adaptive algorithm's capability to produce robust meshes, ensuring reasonable accuracy and efficient computing time. Moreover, the study highlights the potential for the scheme's effective application in complex structural dynamic problems, such as those subjected to seismic or erratic wind loads. It also emphasizes its suitability for general nonlinear analysis problems, establishing the versatility and reliability of the proposed adaptive mesh generation scheme.

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

Assessment of Extreme Wind Risk for Window Systems in Apartment Buildings Based on Probabilistic Model (확률 모형 기반의 아파트 창호 시스템 강풍 위험도 평가)

  • Ham, Hee Jung;Yun, Woo-Seok;Choi, Seung Hun;Lee, Sungsu;Kim, Ho-Jeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.625-633
    • /
    • 2015
  • In this study, a coupled probabilistic framework is developed to assess wind risk on apartment buildings by using the convolution of wind hazard and fragility functions. In this framework, typhoon induced extreme wind is estimated by applying the developed Monte Carlo simulation model to the climatological data of typhoons affecting Korean peninsular from 1951 to 2013. The Monte Carlo simulation technique is also used to assess wind fragility function for 4 different damage states by comparing the probability distributions of the window system's resistance performance and wind load. Wind hazard and fragility functions are modeled by the Weibull and lognormal probability distributions based on simulated wind speeds and failure probabilities. The modeled functions are convoluted to obtain the wind risk for the different damage levels. The developed probabilistic framework clearly shows that wind risk are influenced by various important characteristics of terrain and apartment building such as location of building, exposure category, topographic condition, roof angle, height of building, etc. The risk model presented in this paper can be used as tools to predict economic loss estimation and to establish wind risk mitigation plan for the existing building inventory.

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF