• Title/Summary/Keyword: 풍 하중

Search Result 400, Processing Time 0.025 seconds

Modified Modulus of Elasticity of Concrete Column with Steel Bars (철근을 고려한 콘크리트 기둥의 수정탄성계수)

  • Yoon, Dong-Yong;Song, Hyung-Soo;Jang, Won-Seok;Min, Chang-Shik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.101-111
    • /
    • 2005
  • In this study, it is investigated the modified modulus of elasticity of the reinforced concrete columns including the longitudinal reinforcing steels as well as the confinement effect of the core concrete due to the transverse reinforced steel through the literature reviews. Equations are derived in order to evaluate the modified modulus of elasticity for the reinforced compressive concrete including the confinement effect. The finite element analysis for the 20 story reinforced concrete building is undertaken as a case study depending on the steel ratio and modulus of elasticity, and the analysis results are discussed.

Numerical Analyses on Moment Resisting Behaviors of Electric Pole Foundations According to Their Shapes (기초형상에 따른 전철주기초 모멘트 저항거동에 관한 수치해석 연구)

  • Lee, Su-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.85-97
    • /
    • 2013
  • Electric pole foundations for overhead catenary system of railroad should be designed so that they may resist significant overturning moment but relatively small vertical forces. Also they should have proper shapes to be installed at restricted narrow areas adjacent to railroad track. In this paper the moment responses of rectangular pole foundations according to their shapes were investigated numerically. A three-dimensional finite element method was developed and verified so that the numerical behaviors of the foundation resisting the overturning moments were compared reasonably well with those from an existing real-scale load test. The influences of aspect ratio, varying section with depth and loading directions for rectangular section were investigated using the developed numerical method. From the numerical results, the optimized shapes of pole foundation for more effective and economic installation adjacent to railroad track are proposed.

Vibration Control of Working Booms on Articulated Bridge Inspection Robots (교량검사 굴절로봇 작업붐의 진동제어)

  • Hwang, In-Ho;Lee, Hu-Seok;Lee, Jong-Seh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.421-427
    • /
    • 2008
  • A robot crane truck is developed by the Bridge Inspection Robot Development Interface(BRIDI) for an automated and/or teleoperated bridge inspection. This crane truck looks similar to the conventional bucket crane, but is much smaller in size and light-weight. At the end of the telescoping boom which is 12m long, a robot platform is mounted which allows the operator to scan the bridge structure under the deck trough the camera. Boom vibration induced by wind and deck movement can cause serious problems in this scanning system. This paper presents a control system to mitigate such vibration of the robot boom. In the proposed control system, an actuator is installed at the end of the working boom. This control system is studied using a mathematical model analysis with LQ control algorithm and a scaled model test in the laboratory. The study indicates that the proposed system is efficient for the vibration control of the robot booms, thereby demonstrating its immediate applicability in the field.

Lateral Stiffness and Natural Period Evaluation of Flat Plate Tall Buildings for Wind Design (내풍설계를 위한 초고층 무량판 건축물의 횡강성 및 고유주기 산정)

  • Park, Je-Woo;Kim, Hong-Jin;Jo, Ji-Seong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.73-80
    • /
    • 2010
  • Wind-induced vibration is one of the important structural design factors for serviceability of tall buildings. In order to evaluate the reliable wind-loads and wind induced-vibration, it is necessary to obtain the exact natural period of buildings. The discrepancy in the natural period estimation often results in the overestimation of wind loads. In this study, the effectiveness of lateral stiffness estimation method for tall buildings with flat plate system is evaluated. For this purposed, the results of finite element analysis of three recently constructed buildings are compared with those obtained from field measurement. For the analysis, factors affecting on the lateral resistance such as cracked stiffness of vertical members, elastic modulus of concrete, effective slab width, and cracked stiffness of link beam are considered. Form the results, it is found that the use of non-cracked stiffness and application of dynamic modulus of elasticity rather than initial secant modulus yields closer analysis result to the as-built period.

Introduce for Development of Pyro Valve of Vehicle Holding Device for KSLV-II (한국형발사체 발사체고정장치용 파이로밸브 개발 소개)

  • Ji, Sang-Yeon;Kang, Sun-Il;Lee, Young-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.26-29
    • /
    • 2017
  • KARI has been conducting R&D for independent development of KSLV-II since 2010. Vehicle holding device is a device for vertically standing SLV on the launch pad of launch complex and fixing the lower part of vehicle in order to firmly fix vehicle so that SLV does not fall from an external load such as a wind load. When thrust generated after the 1st stage engine ignition of SLV must exceed the takeoff weight of vehicle, and holding device should be quickly released so that it does not interfere with takeoff of vehicle like other ground equipment at the beginning of the launch. Pyro-valve is one of the key components constituting VHD, and it should have high reliability and quick response characteristics with similar functional parts applied to launch vehicle separation device and satellite separation device. Through this paper, I intend to broaden the overall understanding of the development process of pyro-valve for VHD and KSLV-II.

  • PDF

Nonlinear Seismic Analysis of Steel Buildings Considering the Stiffnesses of the Foundation-Soil System (기초지반강성을 고려한 철골 건축구조물의 비선형 지진해석)

  • Oh, Yeong Hui;Kim, Yong Seok
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.173-180
    • /
    • 2006
  • The seismic responses of a building are affected by the base soil conditions. In this study, linear time-history seismic analysis and nonlinear pushover static seismic analysis were performed to estimate the base shear forces of 3-, 5-, and 7-story steel buildings, considering the rigid and soft soil conditions. Foundation soil stiffness, based on the equivalent static stiffness formula, is used for the damper, one of the Link elements in SAP 2000. The base shear forces of the steel buildings, estimated through time-history analysis using the general-purpose structural-analysis program of SAP 2000, were compared with those calculated using the domestic seismic design code, the UBC-97 design response spectrum. and pushover static nonlinear analysis. The steel buildings designed for gravity and wind loads showed elastic responses with a moderate earthquake of 0.11 g, while the elastic soft-soil layer increased the displacement and the base shear force of the buildings due to soil-structure interaction and soil amplification. Therefore, considering the characteristics of the soft-soil layer, it is more reasonable to perform an elastic seismic analysis of a building's structure during weak or moderate earthquakes.

Evaluation of Reinforcing Performance of Window Protection Device Against Strong Wind (강풍에 대비한 창호보호장치의 보강성능 평가)

  • Park, Won Bin;Kim, Hong Jin
    • Journal of the wind engineering institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.155-161
    • /
    • 2018
  • In modern society, damage caused by strong winds such as typhoons is expected to increase due to urbanization and global warming. In order to test the reinforcement performance of the newly developed window protection device, two-point force test and uniformly distributed load test were carried out on non-reinforced plate glass. It reinforcement performance of the window protection device was evaluated based on the flexural performance improvement. The analytical performance of the window protection device was evaluated by analysis using differential equations of elastic loading method and deflection curve and Midas-Gen. First, the analytical window protection device was evaluated by formulae derived using differential equations of elastic loading and deflection curve. The validity of the derived formulae investigated by comparing the maximum deflection of the central part of the plate with the experimental value and the theoretical value at maximum load. Then the results were compared with those by finite element FE method using Midas-Gen. Under the experimental conditions, with the window protection device, stress reduction effect up to 40% and deflection reduction up to 71.4% under the same load were obtained. It was also found that it is advantageous to perform the FE analysis using the plate element when the performance is evaluated because the error of FE analysis result using plate elements is far less than that using beam elements.

Buffeting Responses of Concrete Cable-stayed Bridge Considering Turbulent Characteristics of Bridge Site (현장 풍속 특성을 반영한 콘크리트 사장교의 버페팅 응답)

  • Kim, Sung-Ho;Yhim, Sung Soon;Kwon, Soon-Duck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.97-104
    • /
    • 2011
  • This study presents the aerodynamic admittance function of bridge girder under turbulent flow generated from wind velocity spectrum measured at bridge site. Three dimensional buffeting analysis of concrete cable-stayed bridge were performed considering aerodynamic admittance functions obtained from four different methods. It is revealed from the analysis that vertical buffeting responses considering proper aerodynamic admittance functions were just half of that neglecting aerodynamic admittance function. Grid turbulence was found to relatively lower the aerodynamic admittance function at low frequency range, and to underestimate the buffeting wind forces. It is recommended to use the aerodynamic admittance function evaluated from flutter derivatives or measured at active turbulence in order to properly predict the buffeting responses of bridges.

Full Scale Measurement on Stay Cables of a Cable Stayed Bridgefor Estimation of Damping Ratios (실교량 계측에 기반한 사장 케이블의 감쇠비 추정)

  • Kim, Saang-Bum;Im, Duk-Ki;Kim, Chang-Hyun;Lee, Jong-Sup
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.421-424
    • /
    • 2009
  • 사장교 케이블의 감쇠비를 추정하기 위하여 실교량 계측을 수행하였다. 사장교 케이블은 감쇠비가 낮고, 고유 진동수가 케이블의 길이에 따라 넓은 범위에 걸쳐 분포하므로, 바람이나 지점 가진에 의하여 과도한 진동이 발생될 수 있다. 케이블 진동 현상의 원인과 발생되고 진행되는 구조는 다양하나, 진동 현상의 가장 중요한 요소는 감쇠비이며, 케이블 진동의 과도한 진동을 감소시키기 위하여, 케이블의 감쇠비를 증가시키는 방법이 널리 사용되고 있다. 사장교 케이블의 다양한 진동 현상에 대한 발생 여부를 판단하고, 케이블 댐퍼와 같은 여러 제진 대책을 설계하고, 설치된 케이블 제진 대책의 성능을 검증하기 위해서는, 케이블의 감쇠비를 추정하는 것이 매우 중요하다. 일반적으로 사용되어져 온 케이블의 감쇠비 추정 방법은 정해진 모드로 자유 진동을 발생시킨 후, 진폭의 감소 추세로부터 Logarithmic Decrement를 계산하여 감쇠비를 구하는 방법이다. 그러나 수백m에 이르는 긴 케이블에서 정해진 모드의 자유 진동을 발생시키는 것은 쉽지 않다. 최근에는 상시 진동으로부터 감쇠비를 추정하는 여러 기법들이 개발되어져 왔으며, Frequency Domain Decomposition Method나 Stochastic Subspace Identification Method 등이 많이 사용되고 있다. 이 논문에서는, 상시진동 기반의 기법들을 사용하여, 사장교 케이블의 감쇠비를 추정하였으며, 추정된 감쇠비의 신뢰도를 높이기 위해, 측정시간을 늘리고, 가진 풍하중의 영향을 반영하여 보정하였다. 또한 추정된 감쇠비를 Buffeting 진동과 와류 진동과 같이 진동 현상과 진폭별로 분석하였다.

  • PDF

Reliability Analysis of Tripod Support Structure for Offshore Wind Turbine using Stress Concentration Factor (응력집중계수를 이용한 해상풍력터빈 트라이포드 지지구조물의 신뢰성해석)

  • Lee, Sang Geun;Kim, Dong Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.2
    • /
    • pp.92-100
    • /
    • 2016
  • Reliability analysis of tripod support structure for offshore wind turbine was performed. Extreme distribution function of peak response due to wind and wave loads was estimated by applying peak over threshold(POT) method. Then, stress based limit state function was defined by using maximum stress of support structure which was obtained by multiplying beam stress and concentration factor. The reliability analysis result was compared when maximum stress was calculated from shell element. Reliability index was evaluated using first order reliability method(FORM).