• Title/Summary/Keyword: 풍환경 분석

Search Result 145, Processing Time 0.027 seconds

Analysis of Wind Force Coefficients for Structural Design of Houses (하우스의 구조설계를 위한 풍력계수의 분석)

  • 이석건;이현우;이종원
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1993.05a
    • /
    • pp.16-17
    • /
    • 1993
  • 하우스에 대하여 풍하중을 고려한 구조해석을 수행할 때 적용하는 풍력계수는 각국마다 차이가 있고 우리나라에서도 실험이나 이론적으로 규명된 바가 거의 없는 실정이다. 따라서 현 실정에 맞는 하우스의 구조해석에 필요한 풍력계수에 대한 규명이 필요할 것으로 판단된다. 이에 본 연구는 단동, 2연동 및 3연동하우스에 대하여 풍동실험을 통해 측정된 풍압을 이용하여 풍력계수를 산정하고 그 변화를 규명하여 풍하중 산정에 필요한 합리적인 풍력계수 분포 단면도를 작성하기 위한 기초 자료를 제공하기 위하여 수행되었다. (중략)

  • PDF

Estimation of Design Wind Velocity Based on Short Term Measurements (단기 관측을 통한 설계풍속 추정)

  • Kwon, Soon-Duck;Lee, Seong Lo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3A
    • /
    • pp.209-216
    • /
    • 2009
  • The structural stability as well as economical efficiency of the wind sensitive structures are strongly dependant on accurate evaluation of the design wind speed. Present study demonstrates a useful wind data obtained at the wind monitoring tower in the Kwangyang Suspension Bridge site. Moreover the Measure-Correlate-Predict (MCP) method has been applied to estimate the long-term wind data at the bridge site based on the wind data at the local weather station. The measured data indicate that the turbulent intensities and roughness exponents are strongly affected by the wind direction and surrounding topography. The new design wind speed based on MCP method is 20m/s lower than that at the original estimation, and the resulting design wind load is only 36% of the old prediction. The field measurement of wind data is recommended to ensure the economical and secure design of the wind sensitive structures because the measured wind data reveal much different from the estimated one due to local topography.

Two-dimensional numerical simulation of flow around a High Speed Train using EDISON_CFD (EDISON_CFD를 이용한 고속열차의 운용환경에 따른 2차원 전산유동해석)

  • ;Jo, Yeong-Hui;Jang, Gyeong-Sik
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.371-376
    • /
    • 2013
  • 고속열차의 운행속도가 증가함에 따라 이전보다 공기역학적인 요소들의 중요성이 커지고 있다. 열차와 터널의 형상설계뿐만 아니라 주변 환경을 위해 고속 주행하는 열차 주변의 유동장을 이해할 필요성이 있다. 본 연구에서는 고속 주행으로 인해 열차 주변에 발생하는 열차풍을 분석하여 선로 주변에 작용하는 풍하중을 계산하였고, 터널 주행 시 발생하는 압력변동과 객차 연결부의 비정상 열린 공동 유동을 살펴보았다. 그 결과 2차원 해석의 정량적 한계점이 나타났지만, 정성적인 경향은 선행연구와 잘 일치함을 확인할 수 있었다. 따라서 고속열차 주변의 공기역학적 특성의 이해와 열차 및 터널의 형상 변화에 따른 상대적인 비교를 위해서는 EDISON_CFD를 이용한 2차원 해석이 유용함을 볼 수 있었다.

  • PDF

Calculating Sea Surface Wind by Considering Asymmetric Typhoon Wind Field (비대칭형 태풍 특성을 고려한 해상풍 산정)

  • Hye-In Kim;Wan-Hee Cho;Jong-Yoon Mun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.770-778
    • /
    • 2023
  • Sea surface wind is an important variable for elucidating the atmospheric-ocean interactions and predicting the dangerous weather conditions caused by oceans. Accurate sea surface wind data are required for making correct predictions; however, there are limited observational datasets for oceans. Therefore, this study aimed to obtain long-period high-resolution sea surface wind data. First, the ERA5 reanalysis wind field, which can be used for a long period at a high resolution, was regridded and synthesized using the asymmetric typhoon wind field calculated via the Generalized Asymmetric Holland Model of the numerical model named ADvanced CIRCulation model. The accuracy of the asymmetric typhoon synthesized wind field was evaluated using data obtained from Korea Meteorological Administration and Japan Meteorological Administration. As a result of the evaluation, it was found that the asymmetric typhoon synthetic wind field reproduce observations relatively well, compared with ERA5 reanalysis wind field and symmetric typhoon synthetic wind field calculated by the Holland model. The sea surface wind data produced in this study are expected to be useful for obtaining storm surge data and conducting frequency analysis of storm surges and sea surface winds in the future.

개발에 따른 연안역의 변화메커니즘

  • Im, Deok-Min;Do, Geun-Yeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.161-162
    • /
    • 2015
  • 근대사회는 기술의 발달과 산업화에 의해 도시에 인구가 밀집됨으로써 효율화, 평균화, 획일화된 개발로 대도시가 형성되었다. 이후에는 도시 자체의 팽창으로 인하여 주변 지역으로의 도시권 확대를 위한 개발이 진행되었으며 연안지역에서는 해수면 매립이라는 방법으로 도시 영역을 바다로 확장하였다. 본 연구에서는 연안역의 특성을 고려한 개발을 통해 기후 및 온열환경, 풍환경 등의 영향을 최소화하고 내륙화되는 것을 방지하는 것에 착목하여 연안역이 갖는 기후환경적 이점을 유지하면서 개발이 이루어지기 위해서는 먼저 연안역의 특성을 파악하고, 개발에 의해 변화되는 환경요소를 유형화하여 연안역 기후환경에 미치는 영향력을 분석할 필요가 있다. 이에 본 연구에서는 연안지역의 지형이나 기후와 같은 특성을 조사하고 개발에 따른 연안역의 변화과정을 메커니즘화하여 영향요소를 도출하고자 한다.

  • PDF

Effect of Wind Speed Profile on Wind Loads of a Fishing Boat (풍속 분포곡선이 어선의 풍하중에 미치는 영향에 관한 연구)

  • Lee, Sang-Eui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.7
    • /
    • pp.922-930
    • /
    • 2020
  • Marine accidents involving fishing boats, caused by a loss of stability, have been increasing over the last decade. One of the main reasons for these accidents is a sudden wind attacks. In this regard, the wind loads acting on the ship hull need to be estimated accurately for safety assessments of the motion and maneuverability of the ship. Therefore, this study aims to develop a computational model for the inlet boundary condition and to numerically estimate the wind load acting on a fishing boat. In particular, wind loads acting on a fishing boat at the wind speed profile boundary condition were compared with the numerical results obtained under uniform wind speed. The wind loads were estimated at intervals of 15° over the range of 0° to 180°, and i.e., a total of 13 cases. Furthermore, a numerical mesh model was developed based on the results of the mesh dependency test. The numerical analysis was performed using the RANS-based commercial solver STAR-CCM+ (ver. 13.06) with the k-ω turbulent model in the steady state. The wind loads for surge, sway, and heave motions were reduced by 39.5 %, 41.6 %, and 46.1 % and roll, pitch, and yaw motions were 48.2 %, 50.6 %, and 36.5 %, respectively, as compared with the values under uniform wind speed. It was confirmed that the developed inlet boundary condition describing the wind speed gradient with respect to height features higher accuracy than the boundary condition of uniform wind speed. The insights obtained in this study can be useful for the development of a numerical computation method for ships.

Experimental Study on the Ground Support Conditions of Pipe Ends in Single Span Pipe Greenhouse (단동파이프하우스의 지점조건 분석을 위한 실험 연구)

  • Lee, Suk-Gun;Lee, Jong-Won;Kwak, Cheul-Soon;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.188-196
    • /
    • 2008
  • Single span pipe greenhouses (pipe houses) are widely used in Korea because these simple structures are suitable for construction by farmers thus reducing labor cost. However, these pipe houses are very weak and frequently damaged by heavy snow and strong wind. Pipe house is constructed by pipe fabricator, which is anchored to the ground by inserting each pipe end into ground to $30\sim40cm$, so the ground support condition of pipe end is not clear for theoretical analysis on greenhouse structure. This study was carried out to find out the suitable ground support condition needed f3r structural analysis when pipe house was designed. The snow and wind loading tests on the actual size pipe house were conducted to measure the collapsing shape, displacement and strain. The experimental results were compared with the structural analysis results for 4 different ground support conditions of pipe ends(fixed at ground surface, hinged at ground surface, fixed under ground and hinged under ground). The pipe house under snow load was collapsed at the eaves as predicted, and the actual strain at the windward eave and ground support under wind load was larger than that under snow load. The displacement was the largest at the hinged support under ground, followed by the hinged at ground surface, the fixed under ground and then the fixed at ground surface independent of displacement direction and experimental loading condition. The experimental results agreed most closely with the results of theoretical analysis at the fixed condition under ground among 4 different ground support conditions. As the results, it was recommended that the pipe end support condition of single span pipe greenhouse was the fixed under ground for structural analysis.

The Analysis of the Effect of .Wind Load on the Structural Stability of an Articulation type Container Crane (풍하중이 관절형 붐을 가진 컨테이너 크레인의 구조 안정성에 미치는 영향 분석)

  • Lee Jung-Myung;Lee Seong-Wook;Han Dong-Seop;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.235-240
    • /
    • 2005
  • Articulation type container cranes are the boom forms an inverted L shape when raise. The inner boom section is nearly vertical when raise and the outer boom section is nearly horizontal. Articulation type container cranes were developed as a lower height crane to meet aircraft clearance requirements. Because the height of an Articulation type container crane is about 70m, the crane is subjected to the effect of Wind load. Therefore, the problem on the effect of Wind load is receiving carefully study. The researches for the effect of wind load on the structural stability of a conventional container crane are conducted. In this study, we carried out the investigation for an articulation type container crane. When a wind load is applied to a container crane, we analyzed the reaction force distribution at each supporting point of a crane with respect to a wind load direction and the effect of the change of the machinery house location on the structural stability rf a crane by carrying out Finite Element Analysis.

  • PDF