• Title/Summary/Keyword: 풍압

Search Result 178, Processing Time 0.018 seconds

A Study on the Traffic Improvement at an Approach Area of Busan Harbor (부산항 제1항로 진입 해역의 통항 개선에 관한 연구)

  • Lee, Yun-Sok;Jung, Min;Song, Chae-Uk;Park, Jin-Soo;Park, Young-Soo;Cho, Ik-Soon
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.345-351
    • /
    • 2007
  • In approaching sea area of Busan harbour, there are many traffic vessels and external forces such as strong seasonal wind and lateral flow are existed. Since the area caused the risk of navigation and ship operators feel hard to enter/depart on Busan port, we carried our the evaluation of traffic risk and propriety at Busan no.1 fairway. In order to assess the safety in the fairway, we analyzed ship's traffic stream based on the marine traffic survey and evaluated the traffic safety of present Traffic Separation Schemes(TSS) and suggest TSS in the research using full mission ship-handling simulators. As a result, the suggested TSS has an effect on improving the traffic safety. In addition, this paper was to suggest the dredging area of depth of water, the passage of towing vessels and control of warships for preventing of maritime accidents in the Busan no.1 fairway.

A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building (업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 -)

  • Chung, Hwan-Kyo;Chung, Kwang-Seop;Lee, Yong-Jun;Shin, Seung-Chul;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.168-178
    • /
    • 2012
  • The objective of this study is applied to office buildings to evaluate quantitative evaluation method about performance of double-skin at design stage to establish the basis for the purpose of evaluation performance. Select the evaluation building about design plan for applying the double-skin using the dynamic heat load analysis program the annual heating and cooling load of before and after the double-skin. Using CFD to analyze wind factor and applied ventilation for realistic results. Effects of double-skin to apply, and control techniques that can be done more realistically proposed through to set and control for shade control mode of ventilator and inside cavity wall of double-skin. Apply for the building the double-skin due to interpretation of the annual heating and cooling loads applied to interpret the quantitative effect confirmed the possibility. According to the form of a double skin was confirmed cavity environmental changes.

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect (커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구)

  • Nam, Jiwoo;Ryou, Hong-Sun;Kim, Dong-Joon;Kim, Sung-Won;Nam, Jun-Seok;Cho, Seongwook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.40-44
    • /
    • 2015
  • National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain wall glass during a fire in a skyscraper increases the loss of lives and property due to the spread of fire. Therefore, the fire resistance of curtain wall glass should be investigated, and technology to prevent glass failure should be developed to prevent fire damage due to spreading fire. It is important to predict the starting point of cracks and the cause of glass failure to prevent it effectively using the limited water in a skyscraper. In this study, double glazed glass was exposed to a radiator in an experiment performed to analyze the thermal characteristics. The results show that glass that was not directly exposed to high temperature and pressure was broken. To identify this failure case, numerical analysis was performed. Three glass specimens were installed in an ISO 9705 room and exposed to radiation using a radiator, and a thermocouple was used to measure the temperature on the surface of the glass. Widely used double glazed glass was analyzed for weakness to fire.

Analysis of the Structural Safety of a Wind-Protecting Wall Using ANSYS/CFX (ANSYS와 CFX를 이용한 방풍벽의 구조 안전성 분석)

  • Yum Sung-Hyun;Kim Chul-Soo;Choi Young-Don
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.138-148
    • /
    • 2006
  • This study was carried out to evaluate the structural safety fur both the attached wind-protecting wall in greenhouse and the detached one installed outside. Regarding the attached wind-protecting wall in greenhouse, the analysis was conducted by doing a fluid-structure coupled field analysis using both CFX-5.7 and ANSYS 8.1 and also under the design condition of an instantaneous maximum wind velocity of $30.9m{\cdot}s^{-1}$. Three kinds of the width ranged from 30 to 90cm were considered in this study. With regard to the detached wind-protecting wall, the structural saffty was analyzed under the pressure difference of 1,117 Pa which corresponded to a wind velocity of $50m{\cdot}s^{-1}$ and the analytical results were also compared with theoretical ones. The result showed that there was little difference in the distribution of velocity overall and total pressure on the lateral side according to the width of the attached wind-protecting wall, but greenhouse with wind-protecting widths of 30 to 60cm has been reinforced to the extent of about 11% when compared with the case of being without the wall. The result also showed that the detached wind-protecting wall with a main-column interval of 3m was not stable so that it was necessary for the detached wind-protecting wall to be adequately reinforced to secure structural stability. Finally, there was great difference between analytical results and theoretical studies. The difference meant that there was some possibility of including errors when a theoretical study was done in three dimensional structure.

A Study on the Proper Crown Height of GT 100,000Ton Cruise ship and DWT 100,000Ton Container ship (10만톤급 크루즈선과 컨테이너선의 적정 마루높이에 관한 연구)

  • Kim, Seungyeon;Lee, Yunsok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.157-162
    • /
    • 2018
  • The increase of risk in port due to the increase in ship size and sea level rises, the standard crown height will increase. In this study, cruise and container ships will need to raise their crown height due to the projected wind pressure areas becoming larger due to the ships' size increase. The mooring assessment was evaluated with the rise of the crown height. The cruise ship of GT 100,000 tons exceeded the permissible breaking force of the mooring line under the crown height conditions of wind speed of 30 kts when the wind direction was $45^{\circ}$ to the direction of the bow. Also, the elevation angle of the pier and mooring line was analyzed and exceeded the crown height, and it was determined that it is necessary to adjust the crown height. Container ships of DWT 100,000 tons were analyzed to exceed the limit of sway motion at the crown height and it was determined that they need to be adjusted to the minimum crown height standard.

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

Development of Antibacterial Hood and Filter for Medical Powered Air Purifying Respirators (PAPR) (의료용 전동공기청정호흡기(PAPR)용 항균성 후드 및 필터 개발)

  • Eunjoo Koh;Nahyun Cho;Yong Taek Lee
    • Membrane Journal
    • /
    • v.33 no.6
    • /
    • pp.398-408
    • /
    • 2023
  • This work developed a hood and filter for antibacterial protective clothing for medical powered air purifying respirators (PAPR) that can be used in medical settings and quarantine against infectious diseases such as Zika virus, Middle East respiratory syndrome (MERS), and coronavirus disease-19 (COVID-19). The hood material of the protective clothing was made of polypropylene spunlace nonwoven fabric (SFS) was used for withstand wind pressure and external physcial pressure. Forthermore, in order to reduce the user's risk of infection, phytoncide-based materials were used on the outer-surface of the hood to achieve a 99.9% antibacterial effect, and the inner-surface were treated with hydro-philic materials to improve absorbency by 25%. In addition to evaluating the artificial blood penetration resistance, dry mi-croorganism penetration resistance, wet bacteria penetration resistance, and bacteriophage penetration resistance required for medical protective clothing hoods, it received a passing evaluation of levels 2-6. Meanwhile, as a result of evaluating the performance of the antibacterial treated spunlace high efficiency particulate air (HEPA) filter, excellent antibacterial properties, dust removal rate, and differential pressure effect were confirmed. All performance evaluations were conducted by an accredited certification body in accordance with the medical PAPR certification standards.

Screening Cases of Potential Extreme Natural Hazards Based on External Event Analysis of Operational Nuclear Power Plants (가동 원전의 외부사건 분석에 기반한 잠재적 극한자연재해의 선별)

  • Chung, Gil-Young;Kim, Gi-Bae;Park, Hyun-Sung;Park, Hyung-Kui ;Choun, Young-Sun;Chang, Soo-Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.699-708
    • /
    • 2023
  • Nuclear power plants (NPPs) consider possible external events, including natural hazards, during the design phase to ensure safe operation. However, in recent years, due to the increasing probability of natural hazards exceeding the design, a careful review of extreme natural hazards and unforeseen external events during the design phase has become necessary. In this study, the objective was to screen potential extreme natural hazards at NPP sites in Korea. Initially, we investigated and analyzed the characteristics of NPP sites and the events caused by external hazards. Furthermore, we analyzed existing literature and research data to establish screening procedures and criteria that suit the actual conditions of domestic NPPs. Based on these criteria and data, we conducted qualitative screening for each NPP site and identified potential extreme natural hazards through quantitative screening and walkdown. As a result of the screening, in addition to internal flooding caused by heavy rain, wind pressure and extreme air pressure caused by extreme winds were screened as potential extreme natural hazards common to all sites. Additionally, at the Kori site, storm surge was selected as the most significant potential extreme natural hazard.