• Title/Summary/Keyword: 품질의 집

Search Result 321, Processing Time 0.031 seconds

A Study on Drain System Development for Stability Increase of Cutting Slope (절개사면의 안정성 증가를 위한 배수시스템 개발에 관한 기초적 연구)

  • Lee, Seung-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.2
    • /
    • pp.15-20
    • /
    • 2005
  • Moutain side ditch is constructed at the top of cutting slopes around road and it drains the surface water that flowed from upper part. About 70% of a country is composed of mountains so occurrence of cutting face by road general observation is necessary. Instability of cutting face is increased by permeation of underground water by rainfall the summer, pore water pressure increases. However, moutain side ditch is constructed on the top of cutting slopes has some troubles. For example, difficulty of qualify control and lack of drainage faculty. Therefore, stability variation of cutting slope is analyzed by hydraulic conductivity and construction depth of mountain side ditch and effective depth of mountain side ditch is decided in this paper.

  • PDF

The Characteristics of Strength Development and Curing Cycle of the Steam Cured Concrete (증기양생 콘크리트의 양생온도주기와 강도발현 특성)

  • Kim, Kwang-Don;Kim, Choon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.63-71
    • /
    • 2010
  • This paper is about a research of steam curing which is one of the curing methods for accelerating the early-age strength of pre-cast concrete. With cylinder mold and mock-up specimen, the research was executed to study the best cycle of steam curing temperature through quantifying cycle of steam curing and maximum temperature, while the required strength is developed under the early-age. Moreover, causes and measurements for the high temperature of concrete, which is due to the steam curing, and the crack, which occurs when removing steel form, are stated. Ultimately, the economical method of producing, which satisfies early-age strength development and quality assurance while manufacturing PC structure, is stated.

Flexural Performance Evaluation of Semi-slim floor Composite Beams for Reduction of Story Height (층고절감을 위한 반슬림플로어 합성보의 휨성능 평가)

  • Lee, E.T.;Lee, Sang Hoon;Jang, Bo Ra
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.165-173
    • /
    • 2008
  • In order to promote the practicality of high-rise steel buildings, the development of structural system which have the better fire resistance, the changeable plan, and the quality control of construction with general composite beams is needed. In this research, new semi-slim floor which the defect of general slim floor was complemented was evaluated to investigate the concrete integration with slim-flor beam and the flexural performance. 5 simply supported semi-slim floor beam tests were performed with parameters; structural form of slab support beam, slab thickness, with or without web opening, and shear connection. Experimental results showed that all specimen s had good ductile behavior.

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

시선집중, 선진안전사업장 - 안전경영 바탕으로 세계 음료시장 개척, 동아오츠카(주) 칠서공장

  • Kim, Seong-Dae
    • The Safety technology
    • /
    • no.183
    • /
    • pp.19-21
    • /
    • 2013
  • 동아오츠카(주)는 청량음료를 제조하는 식음료 제조회사이다. 당초 동아제약 식품사업부에 속해있었으나 1979년 분리되어 식품회사로서 면모를 갖추고 안양에 제1공장을 설립했다. 특히 지난 1980년 청주에 제2공장을 준공한 것에 이어 1996년 경남 함안에 제3공장 칠서공장을 가동하면서 우리나라 청량음료업계에 새로운 이정표를 세웠다. 동아오츠카(주) 하면 제일 먼저 알카리성 이온음료 포카리스웨트가 떠오른다. 그리스 산토리니의 파란 하늘과 바다, 하얀 집이 어우러져 큰 화제가 됐던 포카리스웨트 광고는 국민들의 뇌리 속에 깨끗하고 맑은 회사 이미지를 각인시키기도 했다. 그 밖에도 검은콩을 우려낸 블랙빈테라티, 녹차음료 그린타임, 과즙음료 데미소다, 콩과 과일을 구워낸 소이조이, 허니레몬 등의 기능성 음료와 한국인의 청량음료라고 할 수 있는 오란씨 등이 대표적인 제품이다. 동아오츠카(주)는 소비자의 요구에 맞게 맛과 기능을 조화하여 21세기 건강 지향 기능성 음료를 만들겠다는 신념으로 세계 음료시장을 개척해나가고 있다. 때문에 제품의 품질을 좌우하는 '안전'이 기업경영의 초석이 되고 있다. 1998년 동아오츠카(주) 칠서공장 무재해 목표 개시 후 14년간 '무재해 12배수' 달성이 가능했던 것도 바로 이 같은 철저한 안전 관리가 원동력이 됐기 때문이다. 안전경영을 바탕으로 우리나라 음료 소비 패턴을 주도해가고 있는 동아오츠카(주) 칠서공장을 찾아가봤다.

  • PDF

A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant (해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구)

  • Park, Chang-Soo;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.

Beam and Diffuse to Global Solar Irradiation Correlation Coefficients for Daejeon (대전지역 직달 및 산란과 전일사 상관계수)

  • Lee, Kwan-Ho;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.11-24
    • /
    • 2019
  • The total solar irradiation on horizontal surfaces is separated into the beam and diffuses components. Although horizontal global irradiance is a commonly measured parameter for many sites, horizontal diffuse irradiance is not so readily obtainable. For such sites that measure global irradiation alone, a simple but reasonably accurate method is required to estimate diffuse irradiance from its global counterpart. This study investigates the applicability of correlation coefficients models correlating hourly diffuse and beam fraction and hourly clearness index in Daejeon. The three diffuse to global correlation coefficients models (Orgill and Holland model, CIBSE Guide J model, and Erbs et al. model) are selected and the three modified beam to global correlation coefficients models are generated. MBE, RMSE, r-squared of Daejeon and Daejeon boundary site-fitted models are compared with the case of original coefficients. The comparison result shows that the beam and diffuse to global solar irradiation correlation coefficients models with boundary site-fitted coefficients are best suitable for Daejeon. Further researches will be conducted to find the boundary site-fitting method using measured data of other cities and correlation coefficients models using solar altitude, cloud cover, and sunshine duration.

Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System (전력계통 고장시 계통연계형 태양광발전시스템의 영향분석)

  • Park, Sung-Hun;Lee, Yong-Sik;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.69-77
    • /
    • 2019
  • Among the main functions of the grid-connected photovoltaic (PV) system, the anti-islanding operation function is a very important problem. Recently, due to the improvement in power generation efficiency and the maintenance advantages in PV system, the use of string inverter has increased so that the possibility of islanding operation has been raised. Generally, when a power system faults, the PV inverter must be disconnected from power system within 10 cycles by the anti-islanding operation function. However, in the real-time of power system, the output power of the PV system within 10cycles is effected. In this paper, we analyzed the effect of grid-connected PV system on power quality in a short time within 10 cycles on fault case of power system using the Matlab Simulink program.

A Segmented Model with Upside-Down Bathtub Shaped Failure Intensity (Upside-Down 욕조 곡선 형태의 고장 강도를 가지는 세분화 모형)

  • Park, Woo-Jae;Kim, Sang-Boo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1103-1110
    • /
    • 2020
  • In this study, a segmented model with Upside-Down bathtub shaped failure intensity for a repairable system are proposed under the assumption that the occurrences of the failures of a repairable system follow the Non-Homogeneous Poisson Process. The proposed segmented model is the compound model of S-PLP and LIP (Segmented Power Law Process and Logistic Intensity Process), that fits the separate failure intensity functions on each segment of time interval. The maximum likelihood estimation is used for estimating the parameters of the S-PLP and LIP model. The case study of system A shows that the S-PLP and LIP model fits better than the other models when compared by AICc (Akaike Information Criterion corrected) and MSE (Mean Squared Error). And it also implies that the S-PLP and LIP model can be useful for explaining the failure intensities of similar systems.

Case study for technical evaluation and check list to decision of optimized TBM (최적 TBM 장비 발주를 위한 선정 기준 및 체크리스트 사례 검토)

  • Kim, Ki-Hwan;Kim, Hyouk;Kim, Seong-Cheol;Kang, Si-On
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.385-392
    • /
    • 2021
  • When ordering a slurry shield TBM to be used for power cable tunneling, the client organizes an evaluation committee composed of experts, suggest the criteria and evaluation method for technical specifications for supplier selection, and based on the manufacturer's technical proposal were attempted to evaluate and select. It is expected to be referred to as a guideline for future projects to using Shield TBM as one of the methods of verifying performance and quality in advance and securing economic feasibility in the shield TBM tunneling in the recent increasing trend.