• Title/Summary/Keyword: 품질모니터링

Search Result 565, Processing Time 0.029 seconds

A feasibility study on Introducing the Reference Fuel(Gasoline) for Testing Vehicles in South Korea (국내 표준연료(휘발유) 도입 필요성 검토 연구)

  • Kang, Hyungkyu;Seong, Sangrae;Song, Hoyoung;Hwang, Inha;Ha, Jonghan;Na, Byungki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.824-835
    • /
    • 2016
  • Although the number of registered cars in South Korea is above 21million and one family has about 1.07 cars, there is no national standard for automobile reference fuel in South Korea. Reference fuel is the fuel used for certificating vehicle performance, emissions and fuel economy. Now, domestic market fuels are used as reference fuel. However, the quality of domestic market fuel is constantly changing by seasonal and fuel manufacturers. It may effect vehicle performance, emissions and fuel efficiency test result. On this study, market fuel quality was monitored and reference fuel standard(draft) was set by reflecting market fuel monitoring result. Reference fuel standard(draft) was applied to GDI and MPI engine. As a result, the difference of fuel economy between fuels meeting the reference fuel standards(draft) was reduced to 1.1% while the difference of fuel economy between market fuels was 3.8%.

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

Adaptive Regulators for Quality Assurance in Resistance Welding (MFDC 저항용접의 적응제어 및 SPC 기능 고찰)

  • Lee, Yong-Ki
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.119-119
    • /
    • 2009
  • 인버터 DC 저항용접의 적용성 증대 : 인버터 DC 저항용접 공법이 SPOT, PROJECTON, SEAM, BUTT 등의 공정에 다양하게 적용되어 저항용접 현장에서 고효율, 친환경적 용접 환경을 만드는데 일조 하고 있다. 특히 자동차의 경량화, 충돌내성 증대, 진동 및 내구성 증대, 공간활용 극대화, 새로운 Design 개념 적용 등의 산업전반에 걸쳐 나타나는 신 Trends로 고 장력 철재의 적용 범위가 확대되고 HSS(High Strength Steel), EHSS(Extra High Strength Steel), UHSS (Ultra High strength Steel ; Hot - Formed Steel )등 다양한 철판의 SPOT 저항용접이 필요하게 되었다. 기존의 AC 단상용접의 전력 특성 상 통전 중 무 통전 시간 과 높은 PEAK 전력, 단상 대 전력 소모로 인한 전력 DROP 등의 문제로 인하여 신소재의 용접 시 매우 많은 Spatter가 발생하고, 높은 용접품질의 확보가 어려워 지므로 이를 대체하기 위한 공법으로 MFDC ( 인버터 DC 저항용접공법 )이 적용되고 있다. 인버터 DC 저항용접의 적응제어 : MFDC라는 높은 효율의 용접 전력원이 확보 됨에도 불구하고 용접현장에서는 원 자재, 도금 등의 품질 산포, 프레스 물의 가공산포, 공기압 산포, 전극 과열 및 마모 등의 요인에 의하여 저항용접 산포가 발생하고 있다. 이는 인위적인 조작이 어렵고 불규칙적이며, 어디서나 산재하고 있는 문제이다. 이를 용접전력 제어 법으로 개선하여 일정한 용접성을 확보하기 위한 노력이 적응제어 기법이다. 정 전류, 정 전력 제어는 정량 제어로 용접 물을 비롯한 용접부의 변화와는 관계없이 설정된 일정량의 전력을 공급하기만 하는데 반하여 적응제어는 적절한 용접 작업 시의 용접 물의 상태, 전극의 가압, 표면 상태 등에 따른 변화 페턴을 기억하고 이후 진행되는 용접에 대하여 정상 페턴과의 차이를 감지 이를 보상하므로 고품질의 용접성을 보장하는 제어기법이다. 따라서 다양한 용접 산포 유발 요인에 의해 용접부의 변화가 발생한다 하여도 그 변화를 감지 하고 적절한 용접전력을 공급한다면 고품질의 용접성을 확보하는데 유용한 공법이 될 수 있다. 인버터 DC 저항용접의 SPC 관리 : SPOT 용접 시 획득할 수 있는 다양한 파라메터에 대하여 모니터링 하고 이 자료를 data 화 하여 품질 관리에 응용하게 되면 양산라인에서 반복적으로 발생되는 문제점을 확인 할 수 있고 이를 통계적 방법으로 추적 개선해 나간다면 용접 불량 감소 및 생산성 향상에 도움이 되며 작업자의 공정 능력 향상 및 기업의 기술축적에도 높은 기여를 할 수 있을 것이다. 용접 적응제어와 다양한 파라메터 모니터링이 한 system에서 이루어 질 때 높은 용접성 확보와 불량률 감소, 원가절감, 생산성 향상 등의 효과가 극대화 될 것이다.

  • PDF

Optical performance monitoring in 16CH WDM system, using FFP-TF (FFP-TF를 활용한 OPM의 16CH WDM시스템 광 성능 모니터링)

  • 이동선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.657-662
    • /
    • 2003
  • The OPM(optical performance monitoring module) is needed in order to monitor optical performance. the most importance of OPM is to measure the wavelength of optical signal. In the past time, it was very difficult to get the wavelength value because they used pilot tone. Since then, using AWG(arrayed waveguide grating) and AOTF(acousto optic tuneable filter), the wavelength and the transmission qualify for multi channel signal have been monitored. In this paper, we chose the fiber fabry-perot wavelength variable filter which be evaluated for optical resolution ability to excellent, so that FBG(fiber bragg grating) was used for setting reference wavelength because chose a wavelength variable filter.

A Study on Customer Satisfaction and Service Quality of Net Promoter Score- A Case Study NDSL (NPS의 고객만족 및 서비스 품질에 관한 연구 - NDSL 사례를 중심으로)

  • Kim, Sang-kuk;Choi, Seon-heui;Huh, Joo-yeun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.525-526
    • /
    • 2019
  • 본 논문에서는 고객추천지수(NPS : Net Promoter Score)를 이용하여 2019년도 이용 고객의 서비스 만족 및 품질에 대하여 모니터링하고 기관의 고객만족 개선 활동에 대한 고객의 의견을 분석하기 위함이다. 한국과학기술정보연구원의 국가과학기술정보통합서비스(NDSL : National Digital Science Library)는 산학연 연구자들에게 고품질 정보를 제공하여 국가 과학기술 혁신에 기여하고자 개발된 과학기술정보 서비스 플랫폼으로, 논문·특허·보고서·동향·저널/프로시딩·연구자·연구기관 등 약 1억건 이상의 콘텐츠에 대한 검색 및 콘텐츠 유형별 전문검색 서비스를 제공합니다. NDSL은 과학기술 연구자를 위한 고품질 정보서비스를 지향합니다. 또한, 쉽게보는 검색결과, 오픈서비스 등을 제공함으로써 과학지식의 발견과 확장을 지원하고 있습니다. 이를 위해 서비스를 경험한 500여 명의 의사결정자를 대상으로 국가과학기술정보통합서비스에 대한 고객충성도를 분석하였다. 이와 같은 연구결과는 인터넷 등 정보의 발달로 고객의 긍정적 또는 부정적인 구전이 급속도로 노출되는 환경에서 고객의 만족도를 관리함으로써 핵심고객을 확보하는데 사전 예측자료로 활용될 수 있다.

Design of a High-quality Seafood Production Support System (고품질 수산물 생산지원시스템 설계)

  • Ceong, Hee-Taek;Ye, Seoung-Bin;Kim, Hae-Ran;Han, Soon-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.9
    • /
    • pp.1623-1632
    • /
    • 2008
  • In food choice, consumers consider importantly food safely and reliability focusing on a high qualify control. Also they are concerned about sustainable production and consumption considering of area and environment. In this paper, We propose and design the high-quality seafood production support system that is based on international sanitary standard haccp, traceability and eco-fiendly seafood certification for safety and reliability of the seafood production. The system is categorized into five part: aquafarm haccp, environmental control monitoring, traceability, disease prevention and messenger service and seafood price inquiry service. The proposed system utilize diverse ubiquitous-it technologies like usn, network cctv, mobile device etc.

WBAN Service Quality Optimization Design Using Error Correction Technique (에러교정기법을 이용한 WBAN 서비스품질 최적화 설계)

  • Lee, Jung-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.657-662
    • /
    • 2019
  • The power consumption of wearable sensors and electrocardiogram regulators should be very low to extend the network lifetime and anticipated QoS( : Quality of Service) control such as error correction and authentication of data processed by WBAN( : Wireless Body Area Network) nodes is important. Therefore, QoS control is the most urgent concern to implement WBAN in health monitoring regulations. For optimal QoS control, we compare the energy efficiency and the average number of transmissions with IEEE 802.15.6 and the error correction method considering energy efficiency. The performance of the proposed error correction technique shows that the energy efficiency and the transmission rate are improved by adjusting the coding rate appropriately using the channel estimation.

Data Quality Analysis of Korean GPS Reference Stations Using Comprehensive Quality Check Algorithm (종합적 품질평가 기법을 이용한 국내 GPS 상시관측소의 데이터 품질 분석)

  • Kim, Minchan;Lee, Jiyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.689-699
    • /
    • 2013
  • During extreme ionospheric storms, anomalous ionospheric delays and gradients could cause potential integrity threats to users of GNSS (Global Navigation Satellite System) augmentation systems. GNSS augmentation ground facilities must monitor these ionospheric anomalies defined by a threat model and alarm the users of safely-of-life applications within time-to-alerts. Because the ionospheric anomaly threat model is developed using data collected from GNSS reference stations, the use of poor-quality data can degrade the performance of the threat model. As the total number of stations increases, the number of station with poor GNSS data quality also increases. This paper analyzes the quality of data collected from Korean GPS reference stations using comprehensive GNSS data quality check algorithms. The results show that the range of good and poor qualities varies noticeably for each quality parameter. Especially erroneous ionospheric delay and gradients estimates are produced due to poor quality data. The results obtained in this study should be a basis for determining GPS data quality criteria in the development of ionospheric threat models.

A Study of MES for the Product Tracking Based on RFID (제품추적을 위한 RFID기반 제조실행시스템에 대한 연구)

  • Kim, Bong-Seok;Lee, Hong-Chul
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • MES(Manufacturing Execution System) is a control system which supports basic activities(scheduling, working process and qualify management, etc) to execute working on the shop floor. As especially MES is a system to decrease the gap between production planning and operating, it executes functions that make decision between management and labor using real-time data. MES for real-time information processing requires certain conditions such as data modeling of RFID, which has recently attracted attentions, and monitoring of each product unit from manufacture to sales. However, in the middle of processing the unit with a RFID tag, transponders(readers) can't often read the tag due to reader's malfunctions, intentional damages, loss and the circumstantial effects; for that reason, users are unable to confirm the location of the product unit. In this case, users cannot avoid tracing the path of units with uncertain clues. In this paper, we suggest that the unique MES based on RFID and Bayesian Network can immediately track the product unit, and show how to evaluate it.

  • PDF

호박음료의 저장 중 품질변화 모니터링

  • 이명희;윤성란;오세금;이정일;이기동
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.137.2-138
    • /
    • 2003
  • 농산물의 효율적인 가공.저장은 농산물의 안정된 공급과 물가안정에 크게 기여하며, 부가가치 향상과 식품관련산업의 국제경쟁력 강화에도 필수적인 요건이라 할 수 있다. 호박은 전국 각지의 유휴지에서 별다른 시비나 농약의 사용없이 재배가능한 농산물로 vitamin C 및 vitamin A의 전구체인 carotene과 무기질, 식이섬유, 전분, 자당, 포도당 등이 풍부하다. 호박은 이뇨작용과 산후부종에 효과가 인정되어 널리 이용되고 있으며, 당뇨병, 야맹증, 각막건조증 등에도 효과가 있다. 국민의 생활수준이 향상되고 사회구조가 변화함에 따라 식품소비의 양상도 크게 변화하여 편의식과 건강 지향적인 가공식품의 수요가 급격히 증가하고 있으며, 이에 부응하여 건강식품에 관한 다각적인 연구가 많이 행해지고 있으나 미비한 실정이다. 호박은 특히 수분함량이 많고 조직의 연화현상 등으로 저장성이 낮아서 경제성이 떨어지므로 호박을 이용한 다양한 가공제품의 개발이 요구된다. 호박의 이용성을 검토하고, 나아가 호박의 부가가치 향상 및 경쟁력을 가진 지역특산물화를 위하여 기능성을 갖춘 건강음료개발을 시도하였으며, 이러한 음료의 유통중 품질변화를 모니터링하였다. 호박음료의 유통중 품질변화는 저장온도(20, 30, 40, 50, 6$0^{\circ}C$) 및 저장기간(0, 2, 4, 6, 8 week)에 따른 중심합성실험계획으로 실험을 행하여, 저장에 따른 당, 산, pH, 갈색도 및 관능적 특성에 대하여 반응표면분석을 하였다. 당도, 산도, pH 및 갈색도의 경우 저장시간에 영향을 많이 받는 것으로 나타났으며, 관능적 특성 중 전반적인 기호도에 있어서는 저장온도 및 저장시간에 영향을 많이 받는 것으로 나타났다. 당도, 산도, pH의 경우 저장온도 및 저장기간에 따라 큰 차이를 보이지 않았다. 갈색도의 경우 저장온도 51.1$0^{\circ}C$ 및 저장기간 7.33 week일 때 최대의 갈색도로 나타났다. 전반적인 기호도 있어서는 저장온도 32.52$^{\circ}C$ 및 저장기간 0.30 week일 때 우수한 것으로 나타났다.

  • PDF