• Title/Summary/Keyword: 표준 필 시험

Search Result 34, Processing Time 0.02 seconds

High Grain Quality Mid-late Maturing Rice Cultivar 'Yechan' with Lodging Tolerance and Multiple Disease Resistance (내도복 복합내병 최고품질 중만생 벼 '예찬')

  • Baek, Man-Kee;Park, Hyun-Su;Nam, Jeong-Kwon;Cho, Young-Chan;Kim, Ki-Young;Kim, Jeong-Ju;Kim, Woo-Jae;Shin, Woon-Chul;Jeung, Ji-Ung;Kim, Choon-Song;Jeong, Jong-Min;Lee, Keon-Mi;Park, Seul-Gi;Lee, Chang-Min;Suh, Jung-Pil;Lee, Jeom-Ho
    • Korean Journal of Breeding Science
    • /
    • v.51 no.4
    • /
    • pp.504-514
    • /
    • 2019
  • 'Yechan' is a high grain quality mid-late maturing rice cultivar with lodging tolerance and multiple disease resistance. It was a derived from a cross between 'Hopum' and 'Iksan537' (cultivar name 'Haepum'). 'Hopum' is a high grain quality mid-late maturing rice cultivar with strong lodging tolerance and 'Haepum' is a high grain quality medium maturing rice cultivar with multiple disease resistance. To shorten the breeding period, another culture method was applied to the F1 plants. 'Yechan' was selected through the pedigree method, yield trials, and local adaptability tests, with a high selection pressure for grain quality, lodging, and disease resistance. The heading date of 'Yechan' was August 14, one day later than that of 'Nampyeong'. 'Yechan' is a cultivar tolerant to lodging and it has short culms. It has multiple disease resistance against rice blast, rice stripe virus, and bacterial blight, including the K3a race, the most virulent race in Korea. The yield of 'Yechan' was similar to that of 'Nampyeong'. 'Yechan' showed excellent grain appearance, superior taste when cooked, and enhanced milling performance; thus, we concluded that it could contribute to the improvement of Korean japonica rice cultivar quality. 'Yechan', a high grain quality mid-late maturing rice cultivar with lodging tolerance and multiple disease resistance, would be suitable for cultivation in the southern plain area in Korea and has been utilized in the breeding programs aimed at enhancing the grain quality and stability for the cultivation of Korean japonica rice (Registration No. 7647).

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

Studies on the Utilization of Korean Native Goat for Meat Production (육자원(肉資源) 개발(開發)을 위한 한국재래산양(韓國在來山羊)의 이용(利用)에 관(關)한 연구(硏究))

  • Ra, Kwang-Yon;Kwon, Soon Ki;Kim, Jong-Woo
    • Korean Journal of Agricultural Science
    • /
    • v.4 no.1
    • /
    • pp.75-83
    • /
    • 1977
  • Korean native goats were used for meat production test, and summarized resalts are as follows. 1. The amounts of feed consumed for Korean Native Goat were significantly higher at day than at night. 2. The feed intake was decreased and live weight gain was lower for the summer period. 3. The concentrate consumption was increased when poor quality of pasture and native grass. 4. Compared between single bran feeding group$(T_2)$ and mixed grain feeding group$(T_3)$, the roughage consumption were similar in both groups. 5. By the use of feeding standard for feeding of Korean Native Goat, the feed convertion of T.D.N, D.C.P, and M. E were decreased. 6. It is necessary to periodically protect from contamination parasitic such like stomach worm, liver flack, nodula worm disease and coccidiosis. 7. The carcass rates of goat at 11-12 months age were higher in $T_3$ feeding group as 44.56% compared with $T_2$ feeding group as 42.17% and tethering group as 35.1% and also the dressed carcass percentage were 33.89%, 30.25% and 29.92% respectively. 8. By increasing the amouat concentrate feeds, fat content in muscle was increased but moisture and ash contents were decreased. 9. The fat caused unacceptable flavour was about 4 percent of total dressed goat meat. 10. Among the spices, clove and pepper were better to improved meat flavour for sausage and can meat processing 11. It was known that the quality of goat meat was suitable for meat processing.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.