• Title/Summary/Keyword: 표준적합성 시험

Search Result 290, Processing Time 0.033 seconds

A Study on The Application of ISO/IEC 17025 Software Accredited Testing Institute Using ISO/IEC/IEEE 29119 and ISO/IEC 25023 (ISO/IEC/IEEE 29119와 ISO/IEC 25023을 이용한 ISO/IEC 17025 소프트웨어 공인시험기관 적용에 관한 연구)

  • Lee, Chang-Hee;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Kim, Myung-Sup;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.97-106
    • /
    • 2020
  • The purpose of this study is to determine how to apply ISO/IEC/IEEE 29119 software test procedures and ISO/IEC 25023 software test evaluation items to software-accredited testing laboratories based on the ISO/IEC 17025 international standard requirements. As a method, the overall requirements for their application to a test laboratory were analyzed by mapping ISO/IEC/IEEE 29119 and ISO/IEC 25023 based on ISO/IEC 17025. According to the mapping analysis, a total of 29 documents were created, including quality manuals, procedures, and test guidelines for the operation of the test laboratory. As a result of the study, a test laboratory management system was developed using Confluence 6.15 software by applying the analyzed results of the overall requirements. The test procedures, documents, and records were stored in, and operated from, this system. Verification of suitability for operation of the test laboratory was conducted by KOLAS evaluators through a document review and an on-site audit at the LG Electronics SW Accredited Test Laboratory in Seoul. In conclusion, it was confirmed through the KOLAS evaluation that the test laboratory management system and the operation of the test laboratory are appropriate and, compared with previous cases, the test laboratory operates effectively, and the overall schedule of accreditation could be shortened.

FlexRay: Protocol, Time Hierarchy, Message Frame, Communication Controller, and Conformance Test (FlexRay: 프로토콜, 시간 계층, 메시지 프레임, 커뮤니케이션 컨트롤러, 적합성 시험)

  • Seokjun Hahn;Sua Shin;Naeun Park;Chan Park;Daegi Lee;Seongsoo Lee
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.668-678
    • /
    • 2023
  • FlexRay is an in-vehicle network with maximum two channels and maximum transmission speed of 10Mbps per channel. FlexRay exploits TDMA (Time Division Multiple Access) and FTDMA (Flexible Time division Multiple Access) to ensure real-time communication with efficient transmission, so it is used for real-time electronic control of safety-critical vehicular modules such as powertrain. This paper explains FlexRay protocol, time hierarchy, message frame, communication controller, and conformance test in detail based on ISO 17458 standard and FlexRay consortium documents.

Study on Direct Tensile Properties and Reliability Review of Steel Fiber Reinforced UHPC (강섬유 보강 UHPC의 직접인장 특성 및 신뢰성 검토에 관한 연구)

  • Park, Ji Woong;Lee, Gun Cheol;Koh, Kyung Taek;Ryu, Gum Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.125-132
    • /
    • 2018
  • In this study, a direct tensile test was planned to identify the tensile performance of UHPC, and the irregularity of cracks, which is a problem of the direct tensile test, was complemented through the introduction of notches at the center of a specimen. In this regard, a number of specimens divided by batch to reduce the deviation of direct tensile test values were fabricated to present reference data with respect to highly reliable direct tensile strength values. In addition, the mechanical properties and reliability of the specimens were examined under the curing conditions of the specified design strength of 120MPa for the steel fiber reinforced concrete with 1.5% fiber volume fraction, which is most suitable for the field application. As a result, the deviation of averages by batch between compressive strength and direct tensile strength did not show a large difference, and all cracks occurred within 20mm in the direct tensile test. At the 95% confidence interval of the direct tensile strength, the range was considerably small in the mean and the standard deviation, and there was no significant difference depending on the curing conditions. The results confirmed that a stable direct tensile test was performed, and highly reliable results were obtained through the fabrication of specimens by batch and test progress.

HPLC analytical method validation of Aralia elata extract as a functional ingredients (두릅 추출물의 기능성 원료 표준화를 위한 HPLC 분석법 검증)

  • Ahn, Eun-Mi;Choi, Song-Am;Choi, Ji-Young
    • Food Science and Preservation
    • /
    • v.24 no.6
    • /
    • pp.795-801
    • /
    • 2017
  • Aralia elata Seemann (AE) has long been used as a folk medicine for the treatment of various diseases including diabetes mellitus, anti-arthritic, and anti-gastric ulcer agent in Korea, Japan, and China. This study was performed to establish a simple and reliable HPLC/UV analytical method for determination of most active anti-hypertensive compound, a 3-O-${\alpha}$-L-rhamnopyranosyl($1{\rightarrow}$2)-${\alpha}$-L-arabinopyranosyl hederagenin 28-O-${\beta}$-D-xylopyranosyl($1{\rightarrow}6$)-${\beta}$-D-glucopyranosylester (HE) for the standardization of the shoot extract of AE as a health functional food ingredient. The quantitative analytical method of HE was optimized by HPLC analysis using reverse-phase C18 column at $40^{\circ}C$ with $H_2O$ and acetonitrile (70:30, v/v) as an isocratic mobile phase at a flow rate of 1.0 mL/min and detection wavelength of UV 205 nm. This HPLC/UV analytical method showed good specificity and high linearity in the tested range of 0.03125-2.0mg/ml with excellent coefficient of determination ($R^2$) of 0.9999. The limit of detection and limit of quantification were $12.0{\mu}g/mL$ and $36.5{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 0.2% and 0.1%, respectively. These results indicate that the established HPLC/UV analytical method is very simple, specific, precise, accurate, and reproducible and thus can be useful for the quantitative analysis of HE as a functional anti-hypertensive compound in AE extract.

Development of Analytical Reference Material for Proficiency Test of Pesticide Multi-residue Analysis in Green-pepper (풋고추 농약다성분분석 정도관리용 분석표준물질 개발)

  • Kim, Jong-Hwan;Choi, Sung-Gil;Oh, Young-Gon;Kwon, Young-Sang;Hong, Su-Myeong;Sung, Mun-Hyun;Lee, Se-Ja;Hwang, Sun-Young;Seo, Jong-Su
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.211-220
    • /
    • 2016
  • This study was to develop the analytical reference material of green-pepper for multi-residue analysis of pesticides. According to the ISO Guide 35, ISO Guide 13528 and EURL-PT protocol, the homogeneity, stability, assigned value and uncertainty were calculated to assess if it was suitable to be used as the proficiency test or quality control. The values of the within-bottle standard variation ($s_{wb}$) and the between-bottle standard variation ($s_{bb}$) were 1.7~3.7% of assigned value according to the requirement of the ISO guide 35. And, the uncertainty ($u^*{_{bb}}$) due to inhomogeneity was 0.8~1.1% for all pesticides. The storage stabilities of ten-pesticides at various conditions were assessed. For all target pesticides, the slop ($b_1$) values were smaller than the corresponding values of $[t_{0.95,n-2}{\times}s(b_1)]$ specified by the ISO guide 35, indicating that there were no statistically significant decreases in the concentration of the target pesticides when the analytical reference material was stored at room temperature ($20{\sim}30^{\circ}C$) for 7 days, freezing ($-20^{\circ}C$) for 30 days and deep freezer ($-80^{\circ}C$. except for bifenthrin, fenpropathrin) for 245 days. For proficiency test by using it developed by Korea Institute of Toxicology, inter-lab test was performed with eight organization performing the residual pesticide analysis. We found that there were some different results among them. Some were assessed as questionable or unacceptable for two pesticides and one organization didn't analyze the six pesticides. From these results, this green-pepper analytical reference material containing ten-pesticides could be used as a tool for the proficiency test to improve the reliability or consistency for pesticide residue's results.

Proficiency Testing for the HPLC Analysis of Azoxystrobin, Imidacloprid and Methabenzthiazuron Residues in Soil (HPLC를 이용한 아족시스트로빈과 이미다클로프리드, 메타벤즈티아주론의 토양 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Im, Geon-Jae
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.218-229
    • /
    • 2015
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On November 2012 the testing was carried out using the soil collected and kept as the moistened state for five years, which was expected to very low residue levels of pesticides. The soil was fortified with azoxystrobin, imidacloprid and methabenzthiazuron in a manner similar to prepare soil samples for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soils treated as different levels, one of which was used to the assessment and another used to confirm. In addition, provided three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty eight institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of azoxystrobin were 48, imidacloprid and methabenzthiazuron 46.

Analysis on the Load Runback Logic for a 500MW Coal Fired Power Plant (500MW급 석탄화력발전소 Load Runback 로직 분석)

  • Kim, Jong-An;Ryu, Kwang-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1842-1843
    • /
    • 2011
  • 화력발전소는 화석연료 에너지를 전기에너지로 변환하는 과정에 참여하는 많은 종류의 기기들이 유기적으로 운전되는 복합시스템이다. 발전소 정상운전 중 어느 한 기기가 갑자기 정지되면, 불안정현상이 크게 발생하고 정상 운전이 어렵게 된다. 그러므로 이러한 상황이 발생하는 경우 빠른 시간 내에 적정한 수준으로 출력을 감소시키고, 새로운 안정운전 상태를 찾아가도록 하는 선행적 제어기능이 필요하게 된다. 화력발전소에 이 목적으로 구현되는 제어기능을 로드런백(Load Runback)이라고 부른다. 특히 화력발전소 보일러는 급수, 연료, 통풍을 담당하는 많은 기기가 많이 동시 운전되고 있으므로, 적합하게 설계된 로드런백 기능이 없다면 신뢰성 운전을 보장하기 어렵다. 이 논문에서는 국내 500MW급 표준화력에서 사용하고 있는 로드런백 기능의 핵심을 분석하였고, 이 분석을 토대로 현재 개발 단계에 국산화 제어시스템에 로드런백 기능을 구현하고자 한다. 실제 발전소 취득한 로드런백 시험 그래프를 제시하고 분석 결과의 타당성을 확인하였다.

  • PDF

Definition of Mutation Operators for FBD Models (FBD 모델 대상 뮤테이션 연산자 정의)

  • Shin, Dong-Hwan;Jee, Eun-Kyoung;Bae, Doo-Hwan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.184-186
    • /
    • 2012
  • Function Block Diagram (FBD)는 산업용 컴퓨터인 Programmable Logic Controller (PLC)의 표준 프로그래밍 언어 중 하나이다. 다양한 시험 기법들의 오류 검출 효과성을 평가하기 위해 뮤테이션 분석 기법이 널리 쓰이고 있는데, FBD 모델 대상 뮤테이션 분석 기법에 대한 연구는 이루어지지 못하였다. 본 연구에서는 FBD 모델 대상 뮤테이션 분석 기법의 토대가 되는 FBD 모델 뮤테이션 연산자를 제안한다. 이를 위해서 FBD 모델의 특성, 다양한 FBD 모델링 오류, 기존의 뮤테이션 분석 기법에 관한 연구를 포괄적으로 분석하여 FBD 모델에 적합한 뮤테이션 연산자를 정의한다. 실제 산업계에서 쓰이는 FBD 모델을 대상으로 뮤테이션 연산자를 적용하고 평가한다.

XML Schema Design for Evaluation Module of Biometric Software (생체인식 소프트웨어의 평가모듈을 위한 XML 스키마 설계)

  • Yoon Young-Mi;Hwang Suk-Hyung;Yang Hae-Sool
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.11a
    • /
    • pp.377-380
    • /
    • 2004
  • 최근 생체인식 분야는 IT 분야의 보안기술과 함께 빠르게 진전되어 왔으며, 현재 생체인식의 중요성이 인식되면서 국내외 생체인식 소프트웨어 시장이 급격히 증가하고 있는 추세이다. 이에 따라 생체인식 소프트웨어의 품질에 대한 평가가 요구되고 있으며. 생체인식 소프트웨어의 품질시험과 평가를 위한 기준으로 평가모듈(Evaluation Module)이 도출되어야 한다. 또한. XML(eXtensible Markup Language) 은 네트워크와 어플리케이션간 교환되어지는 정보를 명세하기 위한 언어로 데이터 교환과 공유에 대한 표준으로 그 응용 영역이 확장되어 적용되고 있다. 본 논문에서는 ISO/IEC 9126과 ISO/IEC 12119를 기반으로 생체인식 소프트웨어에 적합한 품질평가 체계를 위해 XML 스키마를 제안하였다. 실제 생체인식 소프트웨어의 평가모듈(EM)에서는 제안한 XML 스키마를 통해 유효성을 검사한다.

  • PDF

Design and Implementation of SOiVA Metadata Security System (SOiVA 메타데이터 보안 시스템 설계 및 구현)

  • Kim, Youngman;Kim, Hyung Hwan;Jung, Kiyong;Jung, Taesung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.1190-1193
    • /
    • 2010
  • SOiVA는 양방향 동영상 서비스를 위한 TTA 정보통신 표준이다. SOiVA 서비스는 다양한 정보를 표현하기 위해 메타데이터를 이용하는데, 이 메타데이터에는 그 중요성 때문에 반드시 제 3자로부터 보호되어야 하는 내용이 포함되어 있다. 이 중 일부가 외부에 노출되거나 유실 조작될 경우 큰 문제를 야기할 수 있으므로 반드시 적합한 보안 시스템이 필요하다. 본 논문에서는 전자서명과 암호화 등의 기술을 이용해 SOiVA 메타데이터 보안 시스템을 설계하고, 타당성을 검증하기 위해 시스템을 구현하고 예제메타데이터에 대하여 시험하였다.