• Title/Summary/Keyword: 표준자체(標準字體)

Search Result 649, Processing Time 0.034 seconds

Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy (호흡동조 방사선치료 시 호흡유도시스템의 유용성 평가)

  • Lee, Yeong-Cheol;Kim, Sun-Myung;Do, Gyeong-Min;Park, Geun-Yong;Kim, Gun-Oh;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.167-174
    • /
    • 2012
  • Purpose: The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Materials and Methods: Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and after the therapy. Results: The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. Conclusion: The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory guidance system than free breathing or breathing with auditory guidance alone. In particular, the above system was excellent at the reproduction of respiratory cycles in care units. Such a system enables to reduce time due to unstable breathing and to perform more precise and detailed treatment.

  • PDF

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse (강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.78-85
    • /
    • 2019
  • This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.

Optimum Management Plan for Soil Contamination Facilities (특정토양오염관리대상시설의 최적 관리방안에 관한 연구)

  • Park, Jae-Soo;Kim, Ki-Ho;Kim, Hae-Keum;Choi, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.293-300
    • /
    • 2012
  • This study was to investigate the unsuitable rate of the storage facilities, the changes in corrosion process over time after installation according to the status, the time to install the facilities, years elapsed after facilities installation, inspection of methods and motivation, and so on, based on the results of the inspection at the petroleum storage facilities conducted by domestic soil-relate specialized agency to derive optimal management plans which meet the status of soil contamination facilities. The results showed that the facilities more than 5 years after the initial leak test at the time of the installation need to be inspected periodically by considering costs of leak test and remediation of polluted soil. The inspection period can be decided by cost and leak test methods showing discrepancies for the results obtained from individual test whether it was direct or indirect. To compensate these matters, we suggested that the direct inspection method on regular schedule is recommended. On the other hand, the inspection can be voluntarily completed to ease burden of the results by inspection or equivalent level to this inspection method. Also, it may need improved construction supervision and performance test system to minimize the occurrence of the nature defects in installing the facilities as well as the upgrade program for the facilities during intervals of inspection period.

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF

A Study on eDesign Platform for Effective Communication and Information sharing - with an emphasis on process and template (효과적인 커뮤니케이션과 정보공유를 위한 e디자인 플랫폼 구축에 관한 연구 - 프로세스와 템플릿을 중심으로)

  • 윤주현
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.425-436
    • /
    • 2004
  • A new design field called eDesign appears as if eBiz is an online related business in which an industrialized design creates the individual value added facing a digital revolution. The field of eDesign requires a special design process and management methodology regardless of the fact that human sensitivity will be satisfied through a dehumanized computer technique. However, it is the reality of eDesign that has been dependent upon a simple process or project management tool of general design. In this study, we develop an eDesign platform based on an eDesign process and template mainly focused on eBusiness in order to overcome the wrong situation. The template is a kind of document that has a standardization form. We aim to establish a general process through various case projects, store information using a necessary template, and use for the way of visual communication. We propose a standard of eDesign platform that can be widely applied to the field of design, medium and small enterprises focused on IT businesses or design-team through this project performed as an educational-industrial study. It makes it possible to get a detailed process methodology, which can be applied to many small design related companies that don't have their own process yet, and will be a scale for comparing their own process in which the company has a process of opened standard eDesign with it. In addition, it makes possible a systematic control of the own projects within and outside the firm, accumulating information for the firm through the database, and easy communication. Furthermore, it can be applied to check the process of the project as a checklist, and then it will reduce trial and error repeated for every project that has been done.

  • PDF

Availability and Reproducibility Evaluation of High-dose-rate Intraluminal Brachytherapy for Unresectable Recurrent Cholangiocarcinoma (재발한 간담도암 환자에서 시행 한 high-dose-rate intraluminal brachytherapy의 유용성 및 재현성 평가)

  • Park, Ju-Kyeong;Lee, Seung-Hun;Cha, Seok-Yong;Kim, Yang-Su;Lee, Sun-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • General treatment for cholangiocarcinoma is complete surgical resection. However recurrence is common in those patients. In most of cases the purpose of the treatment for patients with recurrent is palliative. Therefore we adopt intraluminal catheter to treat a recurrent patient with high-dose-rate intraluminal brachytherapy. This study aims to evaluate the treatment procedure and set-up reproducibility of intraluminal brachytherapy in the recurrent patient. Study patient was diagnosed at rcT1N0M0 and undergone intraluminal brachytherapy after Arrow Sheath insertion. 3 Gy was delivered in every fraction with a total dose of 30 Gy. We planned dose normalization at distal, proximal and central axis point of narrowed bile duct far from 1 cm. To evaluate set-up reproducibility, we measured distance between distal, proximal treatment target volume point and anterior surface of the thoracic vertebral body respectively for five times before every treatment with dummy seed insertion. Mean distance between distal, proximal treatment target volume point and anterior surface of 10th and 11th thoracic vertebral bodies is 0.5 cm, 6.1 cm and standard deviation is 0.06, 0.08 respectively. In addition, set-up reproducibility was maintained significantly. The patient has been alive with no evidence of disease recurrence for more than a year and has not yet reported severe complications. In conclusion, high-dose-rate intraluminal brachytherapy for unresectable recurrence of cholangiocarcinoma maintains high set-up reproducibility without severe side effects.

Physical and Mechanical Properties on Ipseok-dae Columnar Joints of Mt. Mudeung National Park (무등산국립공원 입석대 주상절리대에 대한 물리역학적 특성)

  • Ko, Chin-Surk;Kim, Maruchan;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.383-392
    • /
    • 2016
  • This study is to evaluate the physical and mechanical properties on the Ipseok-dae columnar joints of Mt. Mudeung National Park. For these purposes, physical and mechanical properties as well as discontinuity property on the Mudeungsan tuff, measurement of vibration and local meteorology around columnar joints, and ground deformation by self-weight of columnar joints were examined. For the physical and mechanical properties, average values were respectively 0.65% for porosity, 2.69 for specific gravity, 2.68 g/cm3 for density, and 2411 m/s for primary velocity, 323 MPa for uniaxial compressive strength, 81 GPa Young's modulus, and 0.25 for Poisson's ratio. For the joint shear test, average values were respectively 3.15 GPa/m for normal stiffness, 0.38 GPa/m for shear stiffness, 0.50 MPa for cohesion, and 35° for internal friction angle. The JRC standard and JRC chart was in the range of 4~6, and 1~1.5, respectively. The rebound value Q of silver schmidt hammer was 57 (≒ 90 MPa). It corresponds 20% of the uniaxial compressive strength of intact rock. The maximum vibration value around the Ipseok=dae columnar joints was in the range of 0.57 PPV (mm/s)~2.35 PPV (mm/s). The local meteorology of surface temperature, air temperature, humidity, and wind on and around columnar joints appeared to have been greatly influenced the weather on the day of measurement. For the numerical analysis of ground deformation due to its self-weight of the Ipseok-dae columnar joints, the maximum displacement of the right ground shows when the ground distance is approximately 2 m, while drastically decreased by 2~4 m, thereafter was insignificant. The maximum displacement of the middle ground shows when the ground distance is approximately 0~2 m, while drastically decreased by 3~10 m, thereafter was insignificant. The maximum displacement of the left ground shows when the ground distance is approximately 5~6 m, while drastically decreased by 6~10 m, thereafter was insignificant.

Variations in Temperature and Relative Humidity of Rough Rice in the Polypropylene Bulk Bag during Waiting Time for Drying (벌크 백 수확 벼의 건조대기 시간 중 온.습도 변화양상 구명)

  • Lee, Choon-Ki;Yun, Jong-Tag;Song, Jin;Jeong, Eung-Gi;Lee, Yu-Young;Kim, Wook-Han
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.4
    • /
    • pp.339-349
    • /
    • 2010
  • The uses of the polypropylene bulk bags having the loading capacities more than 500 kg are increasing in Korea recently as a storage container for rough rice. This study was performed to obtain the basic information on the changes of temperature and relative humidity in the bulk-bag-stored high moisture rough rice during waiting for drying. At the moisture content more than 22% on wet weight basis of paddy, the bulk-bag inside temperature rose up to more than $40^{\circ}C$ and then slid down during storage. For example, in case of Hwaseongbyeo, 26.5% moisture content of rough rice (MCRR) harvested at 46 days after heading (DAH) showed $54.5^{\circ}C$ of peak temperature at 66.8 hours after bulk-bag loading, 22.5% MCRR harvested at 52 DAH exhibited $42.0^{\circ}C$ at 81.1 hours, and 19.7% MCRR harvested at 55 DAH displayed $38.9^{\circ}C$ at 119.0 hours. There were a good linear relationship between peak temperatures of bulk-bag inside and moisture contents of paddy ($r^2$=0.89 in 2005, and 0.87 in 2006), while the slope and intercept of the linear regression equation was affected by the environmental conditions such as ambient temperatures and microbial flora. The peak temperatures increased with the rate of about $2.74-3.33^{\circ}C$ per every 1% increase of moisture content at higher moisture contents of paddy than 19%. The relative humidity varied depending on bulk-bag inside temperature and rough rice moisture content, and showed the range of 94.2% to 99.9% in the central point of the bulk-bag. The results suggested that a rapid drying treatment as soon as possible was needed to produce a good quality of rice when the paddy of high moisture more than 22% on wet basis was harvested in a bulk-bag especially at high ambient temperature.

Analysis of PM2.5 Concentration and Contribution Characteristics in South Korea according to Seasonal Weather Patternsin East Asia: Focusing on the Intensive Measurement Periodsin 2015 (동아시아 지역의 계절별 기상패턴에 따른 우리나라 PM2.5 농도 및 기여도 특성 분석: 2015년 집중측정 기간을 중심으로)

  • Nam, Ki-Pyo;Lee, Dae-Gyun;Jang, Lim-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.183-200
    • /
    • 2019
  • In this study, the characteristics of seasonal $PM_{2.5}$ behavior in South Korea and other Northeast Asian regions were analyzed by using the $PM_{2.5}$ ground measurement data, weather data, WRF and CMAQ models. Analysis of seasonal $PM_{2.5}$ behavior in Northeast Asia showed that $PM_{2.5}$ concentration at 6 IMS sites in South Korea was increased by long-distance transport and atmospheric congestion, or decreased by clean air inflow due to seasonal weather characteristics. As a result of analysis by applying BFM to air quality model, the contribution from foreign countries dominantly influenced the $PM_{2.5}$ concentrations of Baengnyeongdo due to the low self-emission and geographical location. In the case of urban areas with high self-emissions such as Seoul and Ulsan, the $PM_{2.5}$ contribution from overseas was relatively low compared to other regions, but the standard deviation of the season was relatively high. This study is expected to improve the understanding of the air pollutant phenomenon by analyzing the characteristics of $PM_{2.5}$ behavior in Northeast Asia according to the seasonal weather condition change. At the same time, this study can be used to establish the air quality policy in the future, knowing that the contribution of $PM_{2.5}$ concentration to the domestic and overseas can be different depending on the regional emission characteristics.

Study on Deriving Improvements through Analysis of BF Certification Evaluation Indicators for Parks and Park Facilities (공원 및 공원시설 BF인증 평가지표 분석을 통한 개선방향 도출 연구)

  • Kim, Mi Hye;Koo, Bonhak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.13-29
    • /
    • 2022
  • According to the revision of the Convenience Act for Persons with Disabilities, parks and park facilities where the first park development plan is established after December 4, 2021 are mandatory, and parks must be equipped with convenience facilities for the disabled. Hence, this study aims to derive the improvements of the park evaluation index by analyzing the park certification evaluation index, the building certification evaluation index of park facilities, and the evaluation reports of the current certification status cases. As a research method, first, the certification of parks and park facilities were compared and reviewed with the Park Green Act, and differences in the certification process and certification performance were compared and analyzed. Second, differences and common items were derived by analyzing barrier free (BF)-certification evaluation indicators for parks and buildings. Third, improvement plans were derived after analyzing differences and problems in 4 BF-certified parks and four building certification cases of park facilities in certified parks, focusing on the self-evaluation report and examination results. As a result of analyzing the park and building evaluation indicators, the items for which the evaluation purpose, evaluation method, and evaluation items were commonly applied to 7 access roads for each facility, 5 parking areas for the disabled, 2 guide facilities for information facilities, 14 in 5 categories of sanitation facilities, and 1 for other facilities. In the case of sanitation facilities, there is no case where it was evaluated as a park. If the park does not have an attached toilet, the park is certified as a building. Hence, it would be essential to establish the concept of an attached toilet and discuss the application of the evaluation index on the park sanitation facility. The score of buildings in parks and park facilities was lower than that of the self-evaluation results, and the certification grades of buildings declined in three cases. The items with the highest standard deviation were BF walking continuity for parks and the path to the main entrance among access roads for buildings. As a result of analyzing the park and building evaluation results of 19 common evaluation items except for sanitary facilities, the difference in the grades of the evaluation items for each case site except for one item appeared. Therefore, applying common detailed calculation criteria for items evaluated in common with parks and buildings is needed. Since sanitation facilities have no cases of park certification and are not certified as buildings, it is essential to establish the concept of attached toilets and discuss the application of park sanitation evaluation indicators. It is necessary to develop an evaluation index suitable for the characteristics of the park, such as adjusting the items that are not evaluated in parks and establishing an evaluation index considering the ones of parks. It expects that this study would be used as primary data for improving park certification indicators.