• Title/Summary/Keyword: 표면근전도

Search Result 132, Processing Time 0.026 seconds

A Study on H-reflex Change and MVIC Change Depending upon Shouting Type (기합소리 유형에 따른 H-reflex변화와 MVIC변화 분석)

  • Jeong, Ik-Su;Oh, Cheong-Hwan;Lee, Dong-Jin;Lee, Gun-Hee;Lee, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.655-661
    • /
    • 2009
  • This study investigated the effects of different types of shouting actions on the strength of the human body. Both H-reflex and MVIC measures of the rectus femoris muscle were used to investigate effects on impact force and motor performance, in order to find optimum shouting methods. The H-reflex of the soleus muscle gave an electric stimulus to the curve of the knee that contains the tibial nerves. Surface electromyelography was used to collect muscle activity the amplitude increased 28% at action with shouting and 29% at the one immediately after short-time shouting than the one without shouting was. To assess the myoelectric activity of the rectus femoris, a surface electrode was attached to the right side of the lower extremity and to increase 10% and 1% depending upon shouting type. The findings were as follows. Shouting affected not only motor efficiency (H-reflex), but also the amplitude of MVIC, with a positive effect on increased muscle strength. Further comprehensive studies are needed to investigate the many variables of increased muscle strength for general purposes, for instance, shouting and breathing, brain waves, and so on.

The Effects of Microcurrent Stimulation on Erector Spinae Fatigue Index (미세전류 자극이 척주세움근의 피로지수에 미치는 영향)

  • Kang, Da-Haeng
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.545-551
    • /
    • 2013
  • This study aimed to compare the effects of microcurrent stimulation and rest on the fatigue index by applying both to subjects who had accumulated fatigue after performing short-duration physical activity. The experiment was performed at S University from December 2012 to February 2013, on 22 healthy men in their 20s, who were right-handed, and without peripheral or musculoskeletal diseases. All subjects lifted a 10-kg box lift and lower 100 times in 15 minutes. Immediately after that, muscle fatigue index (Median Frequency: MF) and blood fatigue index (Creatine Kinase Lactate: CK, Lactate Dehydrogenase: LDH) were measured by using surface electromyography. The subjects were divided into two groups, and microcurrent stimulation and rest were mediated to the experimental and control groups, respectively, for 20 minutes. After intervention, muscle fatigue index and blood fatigue index were measured and the changes in the accumulated fatigue index were compared. Both groups manifested significantly decreased cumulative fatigue after applying the mediation compared to the pre-intervention level (p < .05), the only exception being the fatigue index of the left erector spinae in the rest group. Compared to the rest group, the microcurrent stimulation group showed a significant decrease in muscle fatigue index (p < .05) but no significant differences were found in the blood fatigue index. Given the results of this study, microcurrent stimulation is considered to be helpful in muscle fatigue recovery for workers who have to perform repetitive movements lifting weights, and additional studies on the correlations of the fatigue recovery with respect to the long-term follow-up of fatigue index and mediation time are necessary.

Short-term Effect of Botulinum Toxin Injection on the Surface EMG of Masticatory Muscles and Jaw Function (교근 부위의 보툴리눔 독소 주사가 저작근의 근전도 및 악기능에 미치는 영향)

  • Lee, Jeong-Yun;Park, Hee-Kyung;Chung, Jin-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.69-77
    • /
    • 2006
  • Botulinum toxin injection has been used in the masticatory muscle area as an effective treatment method of various movement disorders and facial contouring, but its effects on jaw function have not been evaluated. The aims of this study were to evaluate the effects of botulinum toxin type A injection into the masseter muscle on the EMG activities of masseter and anterior temporal muscles, and the limitation of jaw function. Fourteen healthy subjects were recruited. Five subjects were injected with 80 units of botulinum toxin type A(Dysport, Ipsen, Wrexham, UK) into each side of masseter muscle, and nine subjects were injected with saline into the same site as the botulinum toxin group. The surface EMG activities at maximum voluntary contraction of masseter and anterior temporal muscles were recorded before, 1 week, 2 weeks, and 3 weeks after injection. Presence of jaw functional limitations in each subject was investigated using Korean version of Jaw Functional Limitation Scale(JFLS) questionnaire. The masseter muscle EMG was gradually decreased in the botulinum toxin group comparing with that of the control group(p<0.001), but the anterior temporal muscle EMG did not show significant changes. There was significant increases in the mastication (p<0.01), and global jaw limitation(p<0.05) subscales of JFLS at 1 week after injection, but no significant changes in the other subscales including opening, and verbal and emotional expression during the recording periods. Our results suggest that botulinum toxin injection into masseter muscle can affect modest limitation in mastication function at 1 week after injection but recovered to the baseline until 3 weeks after injection. The EMG activity of masseter muscle had been gradually decreased until 3 weeks after botulinum toxin injection but the anterior temporal muscle did not show any significant changes.

A Study on Low Frequency Band Selection as a Fatigue Parameter in Surface EMG during Isotonic Exercise of Biceps Brachii Muscle (상완이두근의 등장성 운동시 근피로인자로서 표면근전도의 저주파수대역 선정에 관한 연구)

  • Lee, Sang-Sik;Lee, Ki-Young
    • Journal of Biosystems Engineering
    • /
    • v.36 no.4
    • /
    • pp.285-289
    • /
    • 2011
  • Muscle fatigue is characterized as a progressive increase in discomfort arising from the active muscle at moderate load levels are maintained. The median frequency is the most commonly used as a parameter to describe muscle fatigue. However, the estimate of the median frequency is difficult to indicate muscle fatigue because of its high standard deviation and instability. This paper investigates the power changes of the appropriate low frequency band as a fatigue parameter in EMG during isotonic exercise. To select the appropriate band, linear regression lines are employed to calculate the slopes and the coefficient of determination. Three females and seven males volunteered to participate in surface EMG recordings placed on the biceps brachii and each recording experiment continued until their exhaustion. The results of experiment shows that the power changes of the selected low frequency band (15~45 Hz) have linear slopes and high determinant coefficients. Therefore, this fatiguing parameter using the power changes of the low frequency band is valid to measure the state of muscular fatigue.

Reproducibility analysis of surface EMG spike variables during isometric voluntary contraction of the biceps brachii muscle (이두박근의 등척성 자의 수축시 표면근전도 신호에서 검출한 스파이크 변수들의 재현성 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1246-1254
    • /
    • 2009
  • The reproducibility of initial value and change over time of surface EMG spike variables(MSA, MSF, MSS, MSD) was investigated in the biceps brachii muscle of 11 healthy subjects. Surface EMG signals were recorded during sustained isometric voluntary contractions for 30 seconds at three contraction levels, 20%, 50%, and 80%MVC, respectively. Each contraction was repeated three times in each of three different days for a total of nine contractions and 99 contractions per %MVC level across the eleven subjects. A total of 297 EMG signals across the different trials, days, subjects, and %MVC levels was saved for the subsequent analysis. The degree of reproducibility was investigated using the intraclass correlation coefficient(ICC) and the standard error of the mean(SEM) based upon the analysis of variance(ANOVA), Results for intercept showed higher reproducibility of the spike variables with about 60%-98% ICC than the variable(ARV, MNF) which had been analyzed before in other researches. And results for slope showed poor reproducibility of the spike variables with about 30%-70% ICC and they were comparable with the variables of other researches.

Optimal Signal Segment Length for Modified Run-test and RA(reverse arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 수정된 Run-검증과 RA-검증에 최적인 신호분할 길이)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1128-1133
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of the weak stationarity. The purpose of this study is to find optimal segment length of surface EMG signal for assessing stationarity with the modified Run-test and RA-test. Ten stationary surface EMG signals were simulated by AR(autoregressive) modeling, and ten real surface EMG signals were recorded from biceps brachii muscle and then modified to have non-stationary structures. In condition of varying segment length from 20ms to 100ms, stationarity of the signals was tested by using six different methods of modified Run-test and RA-test. The results indicate that the optimal segment length for the surface EMG is 30ms~35ms, and the best way for assessing surface EMG signal stationarity is the modified Run-test (Run2) method using this optimal length.

Development of Wearable Robot for Elbow Motion Assistance of Elderly (노약자의 팔꿈치 거동 지원을 위한 착용형 로봇 개발)

  • Jang, Hye-Yoen;Han, Chang-Soo;Kim, Tae-Sik;Jang, Jae-Ho;Han, Jung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.141-146
    • /
    • 2008
  • The purpose of this study is to develop the algorithm which can control muscle power assist robot especially for elderly. Recently, wearable robots for power assistance are developed by many researchers, and its application fields are also variable such as for medical or military equipment. However, there are many technical barriers to develop the wearable robot. This study suggest a control method improving performance of a wearable robot system by using a EMG signal of major muscles and a force sensor signal as command signal of system. The result of the robot Prototype efficiency experiment, the case of Maximum Isometric motion it suggest 100% power of muscle, the man need only 66% of MVIC(Maximum Voluntary Isometric Contraction) to lift 5kg dumbbell without robot assist. However the man needs only 52% of MVIC to lift 5kg dumbbell with robot assist. Therefore 20% muscle power increased with robot assist. Also, we designed light weight robot mechanism that extract the command signal verified and drive the wanted motions.

The Analysis of Rectus Femoris Muscle Fatigue Patterns According to Sex using Dynamometer and sEMG during Isometric Contraction to Normal Subjects (동력계 및 표면근전도를 이용한 정상인의 등척성 수축 시 성별 차이에 따른 대퇴직근의 피로 양상분석)

  • Kim, Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.3
    • /
    • pp.11-17
    • /
    • 2007
  • Purpose: The purpose of this study were to analyze fatigue patterns of the rectus femoris muscle by isometric contraction. Methods: Twenty healthy subjects(10 male, 10 female) participated in this study. Maximal voluntary isometric contraction(MVIC) was measured by the dynamometer. Muscle activity was recorded from the rectus femoris muscle. During the experiment, the subject was seated in the chair. The measured items, median frequency(MDF) and root mean square (RMS), were collected from the surface EMG. All data were analyzed using repeated measures ANOVA. Results: There was significant difference of MVIC between male and female. Endurance time was significant difference by the level of MVIC but no significant in the main effect(sex) and interaction effect. The MDF and fatigue index were significant differences in the interaction effect. The RMS was not significant difference in both of main and interaction effect. The muscle fatigue patterns of female was greater than male after 60% MVIC. Conclusion: This study showed that sex differences of muscle fatigue were started from 60% MVIC.

  • PDF

A Study on the Design of Low Back Muscle Evaluation System Using Surface EMG (표면근전도를 이용한 허리근육 평가시스템의 설계에 관한 연구)

  • Lee Tae-Woo;Ko Do-Young;Jung Chul-Ki;Kim In-Soo;Kang Won-Hee;Lee Ho-Yong;Kim Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.5
    • /
    • pp.338-347
    • /
    • 2005
  • A computer-based low back muscle evaluation system was designed to simultaneously acquire, process, display, quantify, and correlate electromyographic(EMG) activity with muscle force, and range of motion(ROM) in the lumbar muscle of human. This integrated multi-channel system was designed around notebook PC. Each channel consisted of a time and frequency domain block, and T-F(time-frequency) domain block. The captured data in each channel was used to display and Quantify : raw EMG, histogram, zero crossing, turn, RMS(root mean square), variance, mean, power spectrum, median frequency, mean frequency, wavelet transform, Wigner-Ville distribution, Choi-Williams distribution, and Cohen-Posch distribution. To evaluate the performance of the designed system, the static and dynamic contraction experiments from lumbar(waist) level of human were done. The experiment performed in five subjects, and various parameters were tested and compared. This system could equally well be modified to allow acquisition, processing, and analysis of EMG signals in other studies and applications.

Comparative Review on Oriental Medicine Study Utilized Surface Electromyography in Korea, China, Japan (표면근전도를 이용한 한국.중국.일본의 한의학연구 경향)

  • Lee, Hyung Geol;Im, Jeong Gyun;Jung, Da Jung;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.30 no.1
    • /
    • pp.23-34
    • /
    • 2013
  • Background or Objectives : The purpose of this study is to review oriental medicine journal that have been utilize Surface EMG in Korea, China, Japan and compare each country's trend in studies. Methods : We investigated studies in relation to surface EMG through 10 articles in Korea from OASIS, 74 articles in China from CAJ, 6 articles in Japan from J-stage. Results : Of 90 articles, 6 articles in Korea, 7 article in China, 6 articles in Japan, totally 19 articles selected. There was no big differences number of articles, type of articles among three countries. There was differences topic of articles, treatment method of articles among three countries. Conclusion : The result of this study could provide useful information of field of Surface EMG is used in Oriental medicine. Studies about Surface EMG performed in different way in Korea, China, Japan.