• 제목/요약/키워드: 표면근전도

검색결과 132건 처리시간 0.03초

12주 근력강화훈련 동안 표면근전도 신호의 특성 (Characteristics of Surface Electromyography During Strength Training of 12 weeks)

  • 신화경;조상현;차광석
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.109-128
    • /
    • 2003
  • This study tested whether repeated measurement of median frequency (MDF)-related variables could express the muscle power changes during a 12-week DeLome strengthening program, by using consecutive overlapping FFT (Fast Fourier transformation) and integrated EMG (IEMG) from surface EMG data for isometric and isotonic exercise. To evaluate the effect of training, the following were recorded every 3 weeks for the elbow flexors and knee extensors of 5 healthy male volunteers: MVC, lRM, limb circumference, and surface EMG during isometric MVC or isotonic contraction at 10RM load. From the EMG data, IEMG and variables from a regression analysis between MDF and time were obtained. MVC, lRM, IEMG, and initial MDF increased linearly over the training period. The fatigue index and slope of the regression line increased temporarily until the 6th week and decreased thereafter. From these results, there appeared to be enhanced neural recruitment of fast twitch fibers in the first 6 weeks and continued enhancement in the recruitment and hypertrophy of fast twitch fibers, which led to increased fatigue resistance, over the last 6 weeks. Accordingly, the MDF and IEMG analysis technique could demonstrate the effect of the program detected significant changes in both isometric and isotonic contractions. EMG analysis methods can be used to estimate the electrophysiological and histological changes in skeletal muscles during a strengthening program.

  • PDF

최대 등척성 수축시 표면근전도에서 근 수축 개시점 결정을 위한 기법들의 신뢰도 (Reliability of the Onset Time Determinations During Maximal Isometric Contraction in Surface EMG)

  • 정이정;조상현;이정훈;이상헌
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.51-62
    • /
    • 2003
  • The purpose of this study was to compare the relative accuracy of a range of computer-based analysis with respect to EMG onset determined visually by an experienced examiner. Ten healthy students (6 male, 4 female) were recruited and three times randomly selected trials of isometric contraction of wrist flexion and extension were evaluated using four technique. These methods were compared which varied in terms of EMG processing, threshold value and the number of samples for which the mean must exceed the defined threshold, and beyond 7% of maximum amplitude. To identify determination of onset time, ICCs(Intraclass Correlation Coefficients) was used and inter-rater arid intra-rater reliability ranged good in visually derived onset values. The results of this study present that in wrist flexion and extension, the reliability of the inter and intra-examiner muscle contraction onset times through visual analysis showed beyond .971 with ICCs. The reliability of the muscle contraction onset time decision through visual reading, tested with computer analysis, showed a relationship of all the selected analysis methods with ICCs .859 and .871. The objective computer-based analysis comparing with visual reading at the same time is the effective and qualitative data analysis method, considering the specificity of each study method.

  • PDF

필라테스 브릿지 동작 시 소도구와 발의 불안정성 차이에 따른 신체 근육의 근활성도 비교 분석 (Comparative Analysis of the Body Muscle Activity According to the Prop and Different Foot Stability during Pilates Bridge Motion)

  • 김유신
    • 한국응용과학기술학회지
    • /
    • 제38권3호
    • /
    • pp.720-726
    • /
    • 2021
  • 본 연구의 목적은 필라테스 브릿지 동작 시 소도구의 적용과 발의 불안정성 차이에 따른 신체근육의 근전도를 비교·분석하는데 있었다. 본 연구의 대상자는 20대 남성 18명을 대상으로 실시하였고(연령, 22.3±2.1세; 신장, 173.89±4.51cm; 체중, 72.61±4.13kg; 신체질량지수, 24.03±1.31kg/m2), 필라테스 브릿지는 소도구 적용(도구 없음, 링, 짐볼)과 발의 불안정성(기본 바닥, 폼롤러, 보수볼) 차이에 따른 9가지 동작을 수행하였으며, 표면전극 부착 부위는 신체 우측의 상복직근, 하복직근, 외복사근, 장내전근, 대퇴직근, 외측광근, 전경골근, 및 대퇴이두근으로 설정하였다. 본 연구의 결과는 다음과 같다. 필라테스 브릿지 동작 시 짐볼의 적용이 신체 근육의 근활성도에 효과적인 소도구로 검증되었고, 보수볼의 적용이 신체근육의 근활성도에 가장 높은 발의 불안정성으로 검증되었다. 이상의 결과를 종합해보면, 필라테스 브릿지 동작 시 짐볼과 보수볼의 적용이 신체 근육의 근활성도에 지대한 영향력을 미친 것으로 나타났다. 따라서 본 연구의 결과는 신체 근력 강화를 위한 효율적인 필라테스 브릿지 운동을 제시할 수 있을 것으로 기대된다.

굽힘 센서신호를 이용한 인공의수의 제어 (Control of an Artificial Arm using Flex Sensor Signal)

  • 유재명;김영탁
    • 한국지능시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.738-743
    • /
    • 2007
  • 본 연구는, 팔(하완)을 잃은 장애자용 인공 의수를 장애자가 자신의 의도에 따라 제어하기 위한 센서 시스템과 제어알고리즘에 관한 것이다. 먼저 장애자의 여러 가지 동작 의도를 검출할 수 있는 센싱 시스템을 연구하고 이 센싱 시스템으로부터 발생된 신호를 사용하여 인공의수를 제어하는 방법에 대하여 연구한다. 센서로서는 전기 저항식 굽힘 센서를 사용한다. 이 굽힘 센서를 팔의 상완 이두근과 오구완근에 각각 1개씩 단단히 부착한다. 부착된 센서로부터 출력된 신호는 근육의 굴곡량을 나타내며 팔의 동작의도를 판단 할 수 있는 신호처리 시스템을 통과시켜 하완의 굴곡과 신전 운동, 손의 내전과 외전 운동을 구별한다. 그리고 구별된 신호로부터 실제 팔의 운동 각도를 추정하여 인공의수의 각도를 제어한다. 본 연구의 효용성을 증명하기 위해 2개의 액추에이터와 포텐셔미터를 가진 간단한 인공의수를 제작하여 제어 실험을 하였다. 실험에서 실제 팔의 각도와 인공의수의 제어 각도 사이에는 센서 외부에서 발생되는 노이즈 및 인공의수의 회전 관성, 기계적인 마찰 등으로 인한 오차가 발생하였다. 따라서 오차 값과 오차의 변화 값에 근거한 퍼지 제어 알고리듬을 이용하여 재 실험을 한 결과 하완의 굴곡/신전 운동에서는 평균 약 4도, 손의 회내/외 운동에서는 평균 약 3도의 오차가 측정되어, 퍼지제어기를 설치한 이전보다 오차가 크게 개선되었다.

의자 좌면 높이가 척추 세움근과 배곧은근의 근 활성도에 미치는 영향 (Effect of seat height of chair on muscle activity of erector spinae and rectus abdominis)

  • 이원휘
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.476-482
    • /
    • 2017
  • 본 연구는 의자 좌면 높이가 척추 세움근과 배곧은근의 근 활성도에 어떠한 영향을 미치는지 알아보고자 실시하였다. 건강한 남녀 30명을 대상으로 세 가지 높이의 의자 좌면에 앉게 하고 양쪽 척추 세움근과 배곧은근의 근활성도를 표면 근전도 장비를 사용하여 측정하였다. 반복측정된 일요인 분산분석을 통해 세 가지 높이의 의자 좌면에 따른 근활성도의 차이를 비교하였고 유의수준(a)은 0.05로 설정하였다. 연구 결과 의자 좌면 높이에 따라 양쪽 배곧은근의 근활성도는 유의한 차이를 보였고 양쪽 척추 세움근의 근활성도는 유의한 차이가 없었다. 양쪽 배곧은근은 낮은 높이의 의자 좌면에서 정상 높이와 높은 높이의 좌면에 비해 근활성도가 유의하게 증가하였다. 본 연구결과를 통해 앉은 자세에서 의자 좌면의 높이는 배곧은근의 근 활성도에 영향을 줄 수 있으며 배곧은근의 근활성도 증가는 요통과 같은 근골격계 통증을 일으킬 수 있으므로 근골격계 통증을 예방하기 위해 바르게 앉은 자세와 함께 의자 좌면 높이는 중요하다.

거울되먹임 융합 치료가 뇌졸중 환자의 상지 근활성도와 상지 기능에 미치는 영향 (The Feedback Mirror Therapy in Stroke Patients Effect of Muscle Activity and Function of the Upper Extremity)

  • 엄요한
    • 디지털융복합연구
    • /
    • 제13권6호
    • /
    • pp.205-212
    • /
    • 2015
  • 본 연구에서는 거울되먹임치료를 이용하여 뇌졸중 환자의 상지 근육 활성도와 상지 기능적 평가에 미치는 효과에 대하여 알아보고자 하였다. 환자는 거울되먹임 치료군 8명과 동작관찰 훈련군 8명으로 나누어 총 8주간 주 5회, 30분간 시행하였고, 상지 기능을 평가하기 위해 뇌졸중 기능회복 평가와 도수 기능 검사를 이용하였다. 위등세모근, 중간어깨세모근, 위팔두갈래근, 노쪽손목굽힘근, 긴노쪽손목폄근의 근활성도를 평가하기 위해 표면 근전도 시스템을 이용하였고, 연구 결과 노쪽손목굽힘근을 제외한 위등세모근, 중간어깨세모근, 위팔두갈래근, 긴노쪽손목폄근의 근활성도와 뇌졸중 기능회복 검사, 도수 기능 검사 점수에서 대조군과 실험군 모두 전, 후 유의한 차이를 보였다. 이에 따라 거울되먹임 치료가 동작관찰 훈련보다 상지 근활성도와 상지 기능을 향상시키는데 효과적임을 알 수 있었다.

단일관절운동과 복합관절운동 시 슬관절 각도에 따른 대퇴사두근의 표면 근전도 비교 분석 (A SEMG analysis of knee joint angle during close kinetic chain exercise and open kinetic chain exercises in quadriceps muscle)

  • 한상완
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.192-204
    • /
    • 2004
  • The surface electromyographic(sEMG) analyses were knee joint angle during open kinetic chain exercise (OKC) and close kinetic chain exercise (CKC) in vastus medialis (VM), vastus lateralis (VL), and rectus femoralis (RF). Ten subjects with normal , aged 20 to 30(X=27.4, SD=3.23), were randomized Statistical techniques for data analysis were applied paired t-test. The 0.05 level of significane was used as the critical level for rejection of the null hypotheses for the study. And the results were: 1) Both OKC and CKC improved the strength of quadriceps muscle as the knee joint flexion was increased. 2) In OKC, the strength of VM was improved the most at the 30 degree angle. 3) In CKC, the strength of VM was improved the most at the 30 degree angle. 4) The VM/VL ratio was the largest at the 10 and 20 degree angles in OKC and CKC. 5) The VM/VL ratio at 10, 20, and 30 degree angles was significantly different between OKC and CKC (P < 0.05). Base on the results, the OKCE is recommended for the knee joint patients, especially for the patellofemoral pain syndrome patients, during the early phase of rehabilitation. In order to improve strength of the quadriceps, muscle strength training at 30 degree angle is recommended. In order to improve VM/VL ratio, 10 and 20 degree angles are recommended during OKCE and CKCE, respectively. Future researches are warranted comparing electromyographic analysis between OKCE and CKCE in the quadriceps at a certain work lead, and muscle strength performance in the quadriceps at different positions of foot.

  • PDF

LPC 켑스트럼 계수를 이용한 EMG 신호의 기능 인식에 관한 연구 (A Study on Function Recognition of EMG Signal Using LPC Cepstrum Coefficients)

  • 왕성문;정태윤;최윤호;변윤식;박상희
    • 대한전자공학회논문지
    • /
    • 제27권2호
    • /
    • pp.126-134
    • /
    • 1990
  • 본 논문에서는 3전극법으로 피검자의 이두박근과 삼두박근에서 검출한 표면 근전도 신호를 LPC 켑스트럼 계수를 이용하여 유클리드 및 가중 켐스트럼 거리 측정법을 통하여 8가지 팔 운동에 대한 기능분리 및 판별 인식에 관한 실험을 하였다. 유클리드 켑스트럼 거리 측정법의 경우,계수의 수가 8,10,12,14 등으로 증가함에 따라 동작기능 인식률도 각각 94.69, 95.63, 96.56, 96.88[%]로 증가하였으나 인식률의 증가폭은 상대적으로 적으며 가중 켑스트럼 거리 측정법의 경우에는 각각 91.88, 95, 99.69, 96.63[%]의 인식률을 보였다.

  • PDF

경사진 트레드밀에서 전방 걷기와 후방걷기 동안 넙다리네갈래근 활동성 비교: 표면 근전도 분석 (The Effect of Forward Walking and Backward Walking on Quadriceps Muscles with Treadmill Inclination: Surface Electromyographic Analysis)

  • 한상완
    • 한국전문물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.63-70
    • /
    • 2005
  • To compare the effects of forward walking and backward walking on surface electromyographic analysis of quadriceps muscles at treadmill grades of 0%, 5% and 10%, subjects were randomized to eleven athletics (5 females, 6 males), with a mean age of 17.8 years, and a SD of 4.66 years. The values of the surface electromyographic (SEMG) activity of the rectus femoris (RF), vastus lateralis (VL) and vastus medialis oblique (VMO) were measured during forward walking and backward walking on a treadmill at grades of 0, 5 and 10%. The subjects walked for approximately 10 seconds at 4.0 km/h. The data were analyzed by repeated measuring of the two-way ANOVA and analyzed by a paired t-test between forward walking and backward walking. The SEMG activity levels of the RF, VL and VMO were the highest when both the forward walking and backward walking increased incrementally for treadmill grades of 0% to 10%, but the VMO/VL ratio had no significant changes. The SEMG activity levels of the RF, VL and VMO were significantly different between directions. However, SEMG activity levels of the RF, VL, VMO and VMO/VL ratio did not show significant difference among the treadmill grades. No statistically significant interactions were detected between the direction of walking and treadmill grade. Backward walking on the treadmill at 4 km/h and grades of 0%, 5%, 10% elicited a greater SEMG activity on the quadriceps muscles than did forward walking under the same conditions. The results suggest that the quadriceps may be effectively activated by performance at treadmill grades of 10%. This investigation confirms that backward walking up an incline may place additional muscular demands on individuals.

  • PDF

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.