• Title/Summary/Keyword: 폴리아크릴 레진

Search Result 9, Processing Time 0.029 seconds

Effect of Evaluation before Site Application of Poly-acrylic Resin Leakage Repair Materials (폴리아크릴 레진 누수보수재의 선정평가 후 현장 적용에 따른 효과 분석)

  • Cho, Il-Kyu;An, Ki-Won;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.55-61
    • /
    • 2018
  • This study improved the water repair materials of the polyacrylic system applied to concrete structures by controlling expansion, strengthening water resistance, and improving cohesiveness. The improved polyacrylate repair materials were evaluated against the existing products to verify their performance and level of improvement, and applied on-site to the concrete structures that are leaking the improved water. The verification method measured the presence of water leaks and the moisture content of concrete inside. Moisture levels were measured for two months before and after material installation, and at least 0.8 - 1.7% of humidity was reduced after installing polyacrylic resin, and no leakage was found.

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.

A Study on the Application of Water Leakage Repair Materials through the Performance Evaluation of Polyacrylic Resin. (폴리아크릴 레진의 누수보수재 성능평가)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.193-194
    • /
    • 2018
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using acrylics. As a second study, it is confirmed that leachate can be used as a repair material by considering long time under water stability, elongation range test, fatigue resistance test, tube stability test, damage recovery performance ana temperature stability considering leakage environment for polyacrylate. In addition, this material is applied to Expansion Joint to perform leakage repair, and to verify the effect of repairing leakage by monitoring and visual observation of concrete humidification.

  • PDF

Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth (수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구)

  • Choi, Yu-Sung;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.129-146
    • /
    • 2008
  • The aim of this study was to compare and analyze wear resistance of acrylic resin tooth in denture opposing to different types of restoration materials. Also, it aimed to compare and analyze the hardness of three various types of resin artificial teeth when using five different types of denture detergents. In this study three types of artificial teeth were used. As ordinary acrylic resin tooth $Trubyte^{(R)}Biotone^{(R)}$ (Dentsply, U.S.A.) was used, and as high hardness resin tooth Endura $Posterio^{(R)}$ (Shofu, Japan) and Physio $Duracross^{(R)}$ (Nissin, Japan) were used. To compare wear resistance, gold alloy, dental porcelain, and composite resin were used as opposing restorations. In addition, with three types of resin tooth stated above, five types of denture detergents, which are $Yuhanrox^{(R)}$ (Yuhanclorox, Korea), $Polident^{(R)}$ (Yuhan Co., Korea), $Cidex^{(R)}OPA$ (Johnson & Johnson Medical Co., Korea), $Hexamedin^{(R)}$ (Bukwang Pharm Co., Korea) and Daihan sterile $water^{(R)}$ (Daihan Pharm Co., Korea) were used to compare and analyze the effects denture detergents have on the surface hardness. The results of this study were as follow : 1. When composite resin and dental porcelain were used as the opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in ascending order showed decrease of cusp height with significant difference (p<0.05). 2. When gold alloy was used as opposing restoration, there was decrease in the cusp height in order of $Trubyte^{(R)}Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant decrease in high cusp height as compared to two other types of artificial tooth (p<0.05). 3. When composite resin, gold alloy and dental porcelain were used as opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order decreased greatly in weight and these three materials showed significant difference (p<0.05). 4. Comparing the experiment values, decrease in strength had significant difference in all resin artificial teeth before and after the denture detergents were used (p<0.05). 5. When resin artificial teeth were subsided in $Yuhanrox^{(R)}$, $Cidex^{(R)}OPA$, and $Hexamedin^{(R)}$, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order showed decrease in hardness, and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant high decrease hardness as to other two types of artificial teeth (p<0.05). Therefore, Physio $Duracross^{(R)}$ seems to have superior wear resistance, and together with Endura $Posterio^{(R)}$, it presents excellent hardness as compared to $Trubyte^{(R)}$ $Biotone^{(R)}$. However, since this study is fragmentary, it should be given careful consideration and more study need to be done before making a definitive conclusion.

A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING (브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구)

  • Kang, Yong-Joo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.538-553
    • /
    • 1999
  • The purpose of this study was to compare the shear bond strength and the anticariogenicity of glass ionomer cement with conventional bonding resin and fluoride releasing resin. After the shear bond strength test, scanning electron microscopic observation was performed for the evaluation of the fracture patterns in each group. Under the polarizing light microscope, artificially induced carious lesions were evaluated and the lesion depths of the samples were measured using image analyzing program(Image-Pro $PLUS^{TM}$, USA). 50 sound maxillary premolars were used for the bond strength test and another 30 for the anticariogenic test. Data collected were analyzed statistically using Oneway-ANOVA and Scheffe test. The results were as follows: 1. Glass ionomer groups(G-III, IV, V) generally showed the lower bond strength values than resin groups(G-I, II). 2. Among the two resin groups, G-I showed the higher bond strength than G-II without statistically significant difference between them(p>.05). 3. Within glass ionomer groups, statistical significance was found between G-III and G-V with the superior bond strength in G-V (p<.05). 4. Under the SEM, adhesive failure was the predominant fracture pattern in G-I and II, whereas cohesive failures were mainly observed in G-III. In G-IV and V, mixed type of pattern where the both fracture patterns coexisted within samples could be seen. 5. In evaluation of the depth of artificially developed carious lesion, glass ionomer group showed shallower depth than resin groups with statistical significance between G-III and G-I, II(p<.05). Among resin groups, fluoride releasing resin(G-II) showed the shallower depth than conventional resin(G-I)(p<.05).

  • PDF

The Effect of Water Immersion on the Surface Strength and the Flexural Strength of the Acrylic Resin for Occlusal Appliances (교합장치용 아크릴레진의 표면경도와 굴곡강도에 대한 침수의 영향)

  • Lee, Hoy-Youn;Im, Yeong-Gwan;Kim, Byung-Gook;Lim, Hoi-Soon;Kim, Jae-Hyung
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.75-81
    • /
    • 2010
  • By repeating nocturnal bruxism occlusal appliance's wearing condition that is used to cure temporomandibular disorders into the vitro experiment, research aims to find out how moisture infiltrated and drying cycle process affects on the surface microhardness of the resin for occlusal appliance and flexural strength. By utilizing resin for occlusal appliance which is the main component of poly methyl methacrylate, bar shaped sample was produced. For the resin sample utilized as the controlled group 1, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, the resin sample of the controlled group 2 was maintained in a dry condition for 7 days in the normal temperature. After that, each sample's surface microhardness and flexural strength were measured. For the resin sample that is utilized as the experimental sample, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, it was inundated for 8 hours a day and dried in the normal temperature for 16 hours with the continuous process of moisture infiltration and dry cycle process for 30 days. During this cycle process, sample's surface and flexural strength were measured in the 1st day, 7th day, and 30th day. Then, it was statistically analyzed to find out the difference of controlled and experiment group's surface microhardness and flexural strength. Results are 1. For the experimental and controlled group's surface microhardness of the resin for the occlusal appliance, it did not show any significant differences after moisture infiltration and dry cycle process repetition. 2. In case of the flexural strength for resin for the occlusal appliance, experimental group with moisture infiltration and dry cycle for 30 day process had greater effect than the experimental group at the 1st day and controlled group These results can be considered to be utilized from the patients of the temporomandibular disorders towards occlusal appliance used and maintained method.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Effect of polymerization temperature on the mechanical properties of provisional prosthesis resins (중합 온도가 임시 보철용 수지의 기계적 성질에 미치는 영향)

  • Hong, Min-Ho;Ha, Jung-Yun;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.311-318
    • /
    • 2017
  • The purpose of this study was to examine the effects of the curing sequence and polymerization temperature on the flexural strength and microhardness of two provisional resins (Bis-acryl resin composite and polymethyl methacrylate (PMMA)). Polymerization was carried out under various conditions, in air at $25^{\circ}C$ (control) and in hot water (40, 50, 60, 70, and $80^{\circ}C$). The flexural strength test was conducted according to ISO-4049. The Knoop hardness was measured. For the Bis-acryl resin, the temperature up to $50^{\circ}C$ did not increase the flexural strength nor the hardness of the bis-acryl resin composite (p>0.05) but higher temperatures increased the strengths. For the PMMA resin, flexural strength increased with temperatures up to $70^{\circ}C$ and then decreased slightly. Bis-acryl resin composite had higher mechanical properties than the PMMA resin. The effect of heat was more pronounced in the bis-acryl resin composite than in the PMMA resin (p<0.05).

Effect of Saliva Contamination Stage and Different Decontamination Procedures on Bonding Strength of Resin-Modified Glass Ionomer (레진강화형 글라스아이오노머의 초기 결합력과 타액오염 제거의 상관관계)

  • Go, Hanho;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.158-164
    • /
    • 2019
  • The purpose of this study was to compare the bond strength of resin-modified glass ionomer (RMGI) to dentin with saliva contamination at different stages and using different decontamination procedures. Extracted human permanent molars were embedded onto acrylic resin with the dentin surface exposed. Group I was a control group that was conditioned with polyacrylic acid (PAA). Groups II and III were contaminated with saliva before PAA conditioning and Groups IV, V, and VI were contaminated with saliva after PAA conditioning. After saliva contamination, Groups II and IV were dried, Groups III and V were rinsed and dried, and Group VI was additionally conditioned with PAA. After surface treatment, the dentin specimens were filled with RMGI. Group I showed significantly higher bond strength than the other groups. Group VI showed a significantly higher bond strength than the other saliva contaminated groups. However, there were no significant differences in the failure mode between the different groups. Saliva contamination impaired the bond strength of RMGI to dentin, regardless of when the saliva contamination occurred. Decontamination with washing and drying could not improve the shear bond strength of RMGIC. When saliva contamination occurred after PAA conditioning, additional PAA conditioning improved the shear bond strength.