• Title/Summary/Keyword: 폴리머 피뢰기

Search Result 29, Processing Time 0.025 seconds

Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line (전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Park, Choon-Hyun;Cho, I-Gon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

Basis Performance Evaluation and Design of Direct Current Arresters of Railway Rolling Stock (적류 전차 탑재용 피뢰기 설계 및 기본성능평가)

  • 김석수;허종철;이운용;한세원;조한구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.644-647
    • /
    • 1999
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for DC power system of railroad vehicles. The rated voltage is 1500v direct current. The main research works are focused on structure design by finite element method, rat ing vol tape, temporary over vol tape and studies of character int ice of polymeric surge arrester .

  • PDF

The Causes and Countermeasures for failures of Distribution Polymer Surge Arresters (배전용 폴리머 피뢰기의 고장원인 및 대책)

  • Kim, Ju-Yong;Lee, Jae-Bong;Kim, Dong-Myung;Jang, Sang-Ok;Hwang, Gwang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1159-1162
    • /
    • 2003
  • Recently we suffered lot of failures of polymer surge arresters made by same manufacture after one year field operation. In order to set up countermeasures we investigated the causes of failures. We extracted faulted arresters and sound ones which were installed in same pole with faulted ones for the electrical test and dissection. 44 arresters were removed from 8 branch offices. Almost all of faulted arresters hadtracking damage on the interface between inner module and housing and the surface of inner module was very rough and irregular. It was possible to occur moisture ingress into the interface between inner module and housing due to the void of the interface and non tight sealing caps. Lots of sound arresters were failed during the moisture ingress test. This result must relate with tracking damage of faulted arresters. Therefore we can say that arresters had poor interface and sealing system. But we could not found aging and defects of ZnO elements because the electrical performance except moisture ingress test of arresters showed good.

  • PDF

Development and Characteristics Evaluation of Polymer Housing Type Arresrter (폴리머 housing형 피뢰기의 개발과 특성 평가)

  • 조한구;김인성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.82-85
    • /
    • 1997
  • This paper describes the development of new type arrester for 22.9kV class distribution lines, with polymer insulating materials applied to their housings. The new arrester employs silicone insulating material for its housing, instead of the conventional porcelain housing, aiming at reduction in size and weight and explosion proof against internal short circuit failure. And, since the design of sheds is not restricted. it is possible to provide a long surface leakage distance per strike length and improve anti-contamination performance.

  • PDF

A study for short-circuit tests of polymer arrester depends on standards (폴리머 피뢰기 단락회로내력시험에 대한 고찰)

  • Choi, I.S.;Kim, S.S.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1527-1528
    • /
    • 2006
  • This paper presents short-circuit tests for polymer-housed distribution arrestors depends on standards. The compared standards are IEC 60694(2004) and IEEE C62.11 (2005). Major differences depends on standards are prefaulted(pre-failure) method by means of a fuse wire and test procedure.

  • PDF

Study on the relief design for the fault current of polymer arrester (폴리머 피뢰기의 고장전류에 대한 방압 설계기술에 관한 연구)

  • Kim, In-Sung;Park, Hoy-Yul;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1717-1719
    • /
    • 1999
  • The chief advantage of polymer arrester. from design of pressure relief, anti-contamination, electrical failure was reduced by outdoor polymer housing. In the first for development of pressure relief design for polymer arrester, fault current and surge were studied through experiments of electrical. Designed the FRP inner tube and unit modules for pressure relief housing. Tested the performance of unit modules for pressure relief of polymer arrester, and the result was successful. The pressure relief of polymer arrester depend on design pattern of diamond shape and ellipse. Study on the pressure relief of FRP inner tube for outdoor polymer arrester. Designed and manufactured FRP inner tube of polymer arrester. Tested the fault current of polymer arrester per 10 kA, 10 cycle.

  • PDF

Accelerated aging test method and characteristics analysis of polymer housed surge arresters (폴리머 피뢰기 가속열화 방법과 열화특성 분석)

  • Kim, Ju-Yong;Park, Chul-Bae;Kwon, Tae-Ho;Jung, Yeon-Ha
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.210-213
    • /
    • 2007
  • In this study accelerated aging test cycle and equipment was developed for aging test of polymer housed surge arresters under domestic weather condition In order to investigate aging characteristics of polymer surge arresters electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test were conducted. Through the analysis the capability of the proposed method was verified and characteristics data were presented for maintenance of domestic arresters. Based on these results long term reliability assessment method was proposed for polymer housed distribution surge arresters.

  • PDF

Reliability Evaluation of Polymer Arrester with Sealing Integrity for Station and Substation (발.변전용 폴리머 피뢰기의 기밀특성에 따른 신뢰성 평가)

  • Yoo, Dae-Hoon;Lee, Un-Yong;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.326-327
    • /
    • 2006
  • The paper describes the development of arrester for 154kV class power station and substation. The arrester employs silicone insulating materials for Its housing, instead of the conventional porcelain housing. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters for ultra high voltage is investigated with moisture ingress test. The diagnostic techniques are discusses, including watt loss, partial discharge, AC leakage current, 1mA DC voltage and residual voltage.

  • PDF

Characteristics of polymer arrester with pressure relief structure (폴리머 피뢰기의 방압구조 및 특성)

  • Han, Dong-Hee;Cho, Han-Goo;Han, Se-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1109-1112
    • /
    • 2004
  • This study reports on the pressure relief design and braided composite of surge arrester. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. As a solution, this study describes pressure relief design performance of arresters with braided composite module. In general, braided composite has Potential for improved impact and delamination resistance. Manufacturing processes of the braided composite could also be automated and could potentially lead to lower costs. Therefore, in consideration of characteristics of pressure relief for polymer arrester, the fabric pattern of braided composite was decided. And Polymer arrester module was manufactured with braid. The mechanisms of pressure occurrence and relief were investigated basically by analyzing arc energy and the correlation between thermal shock and indoor pressure in pressure relief test.

  • PDF

Electric Field Analysis Method of Polymer arrester (폴리머 피뢰기의 해석기법)

  • Hwang, M.K.;Kim, K.H.;Park, N.S.;Lim, I.T.;Heo, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.303-305
    • /
    • 1997
  • The advantage of application polymer instead of conventional porcelain as the housing material for arrester is that light weight, shorter section length of arrester would be possible due to the use of an insulated hanger (mold compound). also, polymer arrester has very good characteristics in design versatility as well as excellent resistance to moist ingress and pollution performance. The finite element method is widely used to calculate for electromagnetic devices. In this paper, we perform the each conditional analysis of PC with an advanced graphical user interface(GUI) using the vector fields simulator. And we try to analyze electromagnetic fields through the conventional two dimensional analysis in case of high voltage contamination on the electrode of a arrester.

  • PDF