• Title/Summary/Keyword: 폭발위험장소

Search Result 47, Processing Time 0.036 seconds

A Study of Explosion Hazard Proof Modeling for Risk Minimization to Semiconductor & FPD Manufature Equipment and Clean Room (반도체·FPD 제조설비와 클린룸의 RISK 최소화를 위한 폭발위험장소 설정 모델링에 관한 연구)

  • Noh, HyunSeok;Woo, InSung;Hwang, MyungHwan;Woo, JungHwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.78-85
    • /
    • 2018
  • In this study, we analyzed risks of the fabrication process equipment and cleanroom for semiconductor/flat panel display (FPD) manufacturing facilities and studied the fundamental safety measures for the risk factors. We examined the explosion proof design models considering the specificity of equipment and environment, and planned to utilize the findings to provide technical standards and grounds for designing and manufacturing related equipment. We believe that this study will contribute to the establishment of technical standards for semiconductor/FPD industry and businesses in many different ways by providing optimized modeling of high-risk explosion site detection, developing safety standards and hazard countermeasures and voluntary activation of safety certification system for operation of fabrication process equipment.

The Effect of the Change of Wind Velocity on the Classification of Explosion Hazardous Area (폭발위험장소 선정 시 풍속 변화에 관한 연구)

  • Kwon, Yong-Joong;Kim, Dong-Joon
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2018
  • It is very important to classify explosion hazardous area in order to prevent an accident explosion. In order to prevent such a explosion, the Industrial Safety and Health Standards Rules stipulates the establishment and management of explosion hazards in accordance with the criteria set by the Korean Industrial Standards. This study has investigated the range of the explosion hazardous area according to various hole sizes, pressures, vapor densities, and wind velocities in the outdoor flammable liquid tank using KS C IEC-60079-10-1 $2^{nd}$ Ed.(=IEC CODE) and PHAST. The results show that the explosion hazardous areas by IEC CODE have circle shapes. However, the areas by PHAST show ellipse shapes. The different of the explosion hazardous areas increases with the increase of wind velocity.

Dust Explosion Characteristics of Multi-Walled Carbon Nano Tube (다중벽 탄소나노튜브의 분진폭발 특성)

  • Han, In Soo;Lee, Keun Won;Choi, Yi Rac
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.40-47
    • /
    • 2017
  • Dust explosion hazards are always present when combustible dusts are manufactured or handled in the process. However, industries is experiencing difficulty in establishing chemical accident prevention measures because of insufficiency of information on dust explosion characteristics of combustible dust handled in industry. In this study, we investigated experimentally dust explosion characteristics of two kinds of multi-walled carbon nano tubes (MWCNT) different in particle size distribution and examined classification of dust explosion hazardous area for MWCNT manufacturing or handling process by applying the NFPA 499 code. As a result, $P_{max}$, $K_{st}$, LEL, MIE and MIT of MWCNT 1 having $124.2{\mu}m$ median diameter are obtained 6.3 bar, $56bar{\cdot}m/s$, $125g/m^3$, over 1000 mJ, and over $650^{\circ}C$. $P_{max}$, $K_{st}$, LEL, MIE and MIT of MWCNT 2 having $293.5{\mu}m$ median diameter are 6.2 bar, $42bar{\cdot}m/s$, $100g/m^3$, over 1000 mJ, and over $650^{\circ}C$, respectively. MWCNT 1, 2 are not categorized as combustible dust listed in the NFPA 499 Code for classification of dust explosion hazardous area because explosion severity and ignition sensitivity of MWCNT 1, 2 are below 0.35 and 0.01, respectively.

Safety Survey of children according to the city planning area (용도구역별 아동·청소년의 안전실태와 대응방안)

  • Kim, Young-Han
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.243-245
    • /
    • 2015
  • 본 논문은 사고의 발생은 안전하지 못한 장소나 상황으로부터 발생하며, 그러한 장소는 안전수준이 높은 지역이나 사회적 계층 및 가정보다는 그렇지 못한 취약지역이나 취약계층 또는 취약가정에서 상대적으로 높은 사고 발생율과 위험에 직면한 상황이 많이 발생할 것이다. 따라서 지역의 특성에 맞는 집중적인 안전관리 대책을 수립하는 것이 국가적 차원의 안전사고 발생율을 낮추고, 효과적인 사고 예방대책을 수립할 수 있다. 이를 위하여 도시계획구역에 따라 청소년 1,200명을 표본조사 하였으며, 자료처리 방법은 window spss pc 12.0 통계프로그램을 이용하여 분석하였다. 본 연구 결과 주요 사고 유형은 '추락/넘어짐/미끄러져 다친 사고'가 49.2%로 가장 많으며, 사고 장소는 학교주변, 집주변, 여가놀이시설주변이었다. 이것은 본 연구에서 아동청소년들의 주요 활동공간으로 제시한 곳과 일치한다. 용도지역에 따른 아동 청소년의 안전도 차이를 보면 도시 내 상업지역이 사고경험이 가장 많으며, 사고유형은 도시 내 상업지역은 화재, 이물질 섭취, 폭발, 부패 변질, 물체 접촉 등이 많고, 도시내 주거지역과 공업지역, 농어촌지역은 충돌이나 충격사고, 추락/넘어짐/ 미끄러져 다친 사고나 날카로운 물체에 베이거나 찔린 사고가 많은 것으로 나타났다.

  • PDF

Automatic Detection System for Dangerous Abandoned Objects Based on Vision Technology (비전 기술에 기반한 위험 유기물의 자동 검출 시스템)

  • Kim, Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.69-74
    • /
    • 2009
  • Abandoned objects should be treated as possibly dangerous things for public areas until they turn out to be safe because explosive material or chemical substance is intentionally contained in them for public terrors. For large public areas such as airports or train stations, there are limits in man-power for security staffs to check all the monitors for covering the entire area under surveillance. This is the basic motivation of developing the automatic detection system for dangerous abandoned objects based on vision technology. In this research, well-known DBE is applied to stably extract background images and the HOG algorithm is adapted to discriminate between human and stuff for object classification. To show the effectiveness of the proposed system, experiments are carried out in detecting intrusion for a forbidden area and alarming for abandoned objects in a room under surveillance.

  • PDF

A Study on the Inflammable Gas Explosion Triggered by the Electric Discharge Static Eliminator on Voltage Application Type (전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구)

  • Lee Chun Ha;Ok Kyoung Jea;Kim Jum-Ho;Kwon Byung-Duck;Cha Ha-Na;Yun Kea Won
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.22-26
    • /
    • 2004
  • The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode.

Technical/Systemic Approach to Safety Assesment of Thermoprocessing Equipment Consuming LNG for Classification of Hazardous Area (LNG를 사용하는 설비에서의 폭발위험장소 적용 및 구분에 대한 제도/기술적 접근방안)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.33-40
    • /
    • 2011
  • In the hazardous areas where explosive liquids, vapors and gases exist, electrical apparatus/equipment should have explosion-proof construction. The consuming of liquefied natural gas(LNG) has markedly increased in the industrial field, especially in aspect of some thermoprocessing equipment, boiler, dryer, furnace, annealer, kiln, regenerative thermal oxidizer(RTO) and so on. Because it has many merits, clean fuel, safety, no transportation/storage facility and so on. It is strongly recommend that the classification of hazards has to be decided to prevent and protect explosion which may occur in thermoprocessing equipment. In this paper, the operated thermoprocessing equipments in industrial area investigated and explosion risk assessment about LNG leakage from its facilities was performed through numerical calculation and computer simulation. Finally, we suggest the systemic/technical approach for safety assessments of thermoprocessing equipments consumed LNG fuel which are specially subjected to classification of hazardous area.

A Study on the Correlation of MESG and Explosion Pressure (최대실험안전틈새(MESG)와 폭발압력의 상관관계에 대한 연구)

  • Hwang, Kyungyong;Shin, Woonchul;Lee, Taeck-Kie
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.1
    • /
    • pp.29-39
    • /
    • 2016
  • Electrical apparatuses for use in the presence of explosive gas atmospheres have to be special designed to prevent them from igniting the explosive gas. Flameproof design implies that electrical components producing electrical sparks are contained in enclosures and withstand the maximum pressure of internal gas or vapours. In addition, any gaps in the enclosure wall have to designed in such a way that they will not transmit a gas explosion inside the enclosure to an explosive gas or vapours atmosphere outside it. In this study, we explained some of the most important physical mechanism of Maximum Experimental Safe Gap(MESG) that the jet of combustion products ejected through the flame gap to the external surroundings do not have an energy and temperature large enough to initiate an ignition of external gas or vapours. We measured the MESG and maximum explosion pressure of propane and acetylene by the test method and procedure of IEC 60079-20-1:2010.When the minimum MESG is measured, the concentration of propane, acetylene in the air is higher than the stoichiometric point and their explosion pressure is the highest value.

Dangerous Abandoned Object Extraction Model Using Area Variation Characteristics (면적의 변화 특성을 이용한 위험 유기물 형상 추출 모델)

  • Kim, Won
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.39-45
    • /
    • 2020
  • Recently the terrors have been attempted in the public places of the nations such as United states, England and Japan by explosive things, toxic materials and so on. It is understood that the method in which dangerous objects are put in public places is one of the difficult types in detection. While there are the cameras recording videos for many spots in public places, it is very hard for the security personnel to monitor every videos. Nowadays the smart softwares which can analyzing videos automatically are utilized to detect abandoned objects. The method by Lin et al. shows comparatively high detection rates for abandoned objects but it is not easy to obtain the shape information because there is a tendency that the number of the pixels decreases abruptly along the time goes due to the characteristics of short-term background images. In this research a novel method is proposed to successfully extract the shape of the abandoned object by analysing the characteristics of area variation. The experiment results show that the proposed method has better performance in extracting shape information in comparison with the precedent approach.

Influence of Mixture Non-uniformity on Methane Explosion Characteristics in a Horizontal Duct (수평 배관의 메탄 폭발특성에 있어서 불균일성 혼합기의 영향)

  • Ou-Sup Han;Yi-Rac Choi;HyeongHk Kim;JinHo Lim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.27-35
    • /
    • 2024
  • Fuel gases such as methane and propane are used in explosion hazardous area of domestic plants and can form non-uniform mixtures with the influence of process conditions due to leakage. The fire-explosion risk assessment using literature data measured under uniform mixtures, damage prediction can be obtained the different results from actual explosion accidents by gas leaks. An explosion characteristics such as explosion pressure and flame velocity of non-uniform gas mixtures with concentration change similar to that of facility leak were examined. The experiments were conducted in a closed 0.82 m long stainless steel duct with observation recorded by color high speed camera and piezo pressure sensor. Also we proposed the quantification method of non-uniform mixtures from a regression analysis model on the change of concentration difference with time in explosion duct. For the non-uniform condition of this study, the area of flame surface enlarged with increasing the concentration non-uniform in the flame propagation of methane and was similar to the wrinkled flame structure existing in a turbulent flame. The time to peak pressure of methane decreased as the non-uniform increased and the explosion pressure increased with increasing the non-uniform. The ranges of KG (Deflagration index) of methane with the concentration non-uniform were 1.30 to 1.58 [MPa·m/s] and the increase rate of KG was 17.7% in methane with changing from uniform to non-uniform.