• 제목/요약/키워드: 폭발물 검출

Search Result 16, Processing Time 0.025 seconds

Recent Research Trends in Explosive Detection through Electrochemical Methods (전기화학적 방법을 통한 폭발물 검출 연구동향)

  • Lee, Wonjoo;Lee, Kiyoung
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.399-407
    • /
    • 2019
  • The development of explosive detection technology in a security environment and fear of terrorism at homeland and abroad has been one of the most important issues. Moreover, research works on the explosive detection are highly required to achieve domestic production technology due to the implementation of aviation security performance certification system. Traditionally, explosives are detected by using classical chemical analyses. However, in the view of high sensitivity, rapid analysis, miniaturization and portability electrochemical methods are considered as promising. Most of electrochemical explosive detection technologies are developed in USA, China, Israel, etc. This review highlights the principle and research trend of electrochemical explosive detection technologies carried out overseas in addition to the research direction for future exploration.

Adaptive Window-based Detection of Narcotics and Explosives using IMS Signals in Cargo Containers (화물 컨테이너 내 IMS 신호를 이용한 적응 윈도우 기반 마약 및 폭발물 검출)

  • Ju, Heesong;Kim, Donghyun;Cho, Sungyoon;Park, Kyungwon;Kim, Yangsub;Jeon, Wongi;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.23 no.3
    • /
    • pp.57-65
    • /
    • 2022
  • International attempts to smuggle narcotics and explosives using ship or aircraft cargoes are on the rise. With the recent increase in the number of detection cases of narcotics and explosives in Korea, it is important to detect dangerous material (narcotics and explosives) through container searches at ports and airports, which are the main routes. This paper proposes a technique to detect dangerous material in cargo containers using the sampled output signal of ion mobility spectroscopy (IMS). The proposed technique estimates parameters such as a threshold, a window length, and a noise level for ion detection of the target dangerous material by using known materials in the initialization stage. The estimated parameters are used to detect the ions of the dangerous target material inside the containers. The proposed technique can be applied when the peak value of the IMS signal and the ion mobility are varying due to container environments.

A Study on the Evaluation of Classification Performance by Capacity of Explosive Components using Convolution Neural Network (CNN) (컨볼루션 신경망(CNN)을 이용한 폭발물 성분 용량별 분류 성능 평가에 관한 연구)

  • Lee, Chang-Hyeon;Cho, Sung-Yoon;Kwon, Ki-Won;Im, Tae-Ho
    • Journal of Internet Computing and Services
    • /
    • v.23 no.4
    • /
    • pp.11-19
    • /
    • 2022
  • This paper is a study to evaluate the performance when classifying explosive components by capacity using a convolutional neural network (CNN). Among the existing explosive classification methods, the IMS steam detector method determines the presence or absence of an explosive only when the explosive concentration exceeds the threshold set by the user. The IMS steam detector has a problem of determining that even if an explosive exists, the explosive does not exist in an amount that does not exceed the threshold. Therefore, it is necessary to detect the explosive component even when the concentration of the explosive component does not exceed the threshold. Accordingly, in this paper, after imaging explosive time series data with the Gramian Angular Field (GAF) algorithm, it is possible to determine whether there are explosive components and the amount of explosive components even when the concentration of explosive components does not exceed a threshold.

Performance Evaluation of Explosive Specific Bio-receptor Using QCM Sensing Platform for Resonance Frequency Shift Detection (공진점변화검출용 QCM 센싱플랫폼을 이용한 폭발물 특이적 바이오수용체 성능평가)

  • Lim, Si-Hyung;Jeong, Hyun-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.280-284
    • /
    • 2011
  • The mass change during the molecular interaction between explosive specific bio-receptors and target molecules has been measured using quartz crystal microbalance(QCM), which has a mass change detection limit up to ~ng/$cm^2$. The environmental effect on the molecular interaction has been evaluated. In the liquid phase molecular interaction experiments, the high selectivity of the bio-receptor to DNT compared with toluene has been shown and the sensitivity for various concentrations of DNT has been demonstrated.

Trends of Millimeter Wave and Terahertz Imaging Technologies (밀리미터파/테라헤르츠파 영상 기술 동향)

  • Lee, W.H.;Lee, W.J.;Chung, T.J.
    • Electronics and Telecommunications Trends
    • /
    • v.27 no.6
    • /
    • pp.114-123
    • /
    • 2012
  • 밀리미터파 및 테라헤르츠파는 미래 과학 기술의 보고로서 초고속 통신, 보안 검색 등 다양한 분야에 응용/연구되고 있으나, 밀리미터파 및 테라헤르츠파 영상 기술은 고출력 반도체 신호원이나 배열형 검출기와 같은 핵심 부품 기술의 부재로 연구개발 초기 단계에 있다. 밀리미터파 대역에서 100GHz 이상은 테라헤르츠파 대역과 겹쳐지는 부분으로 300GHz 대역의 밀리미터파 및 테라헤르츠파가 갖는 특성인 종이, 섬유 등의 비이온화 물질에 대한 투과성과 금속에 대한 높은 반사도를 이용하면 인구의 집중도가 높은 공공 장소에서의 은닉된 흉기나 폭발물 등의 위험물 영상을 비접촉식으로 획득할 수 있으며, 식품의 가공 또는 유통 과정 중에 발생할 수 있는 식품 이물질을 제품의 손상 없이 구별해 낼 수 있다.

  • PDF

Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement - (중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 -)

  • Song, Byung Chul;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.1041-1051
    • /
    • 2003
  • Neutron induced prompt gamma activation analysis (PGAA) offers a nondestructive, sensitive and relatively rapid method for the determination of trace and major elements and is proven to be convenient for online analysis of minerals, metals, coal, cement, petrochemical, coating, paper as well as many other materials and products. The technique has found many uses in medicine, industry, research, security and the detection of contraband items. This report reviews the present status and future trends of the PGAA techniques. Requirements for the system are neutron source, high resolution HPGe detectors with a high-voltage power supply, an amplifier, analog-to-digital converter, and a multichannel analyzer for the detection and measurement of prompt ${\gamma}$-ray emit form the neutron capture elements. Introducing a ${\gamma}$-${\gamma}$ coincidence system also improves the quality of the ${\gamma}$-ray spectrum by suppressing the background created from the Compton scattering of high energy prompt ${\gamma}$-rays. A PGAA system using a $^{252}Cf$ neutron source is currently under construction for the on-line measurement of several elements in aqueous samples at KAERI. The system can be applied for the detection of chemical weapons and explosives as well as various narcotics.

Analysis for explosives in contaminated soil using the electrochemical method (폭발물 오염토양에서 전기화학법을 이용한 RDX 흔적량의 분석)

  • Ly, Suw Young
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Cyclic voltammetry (CV) and square wave stripping voltammetry (SW) analysis of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) using the double-stranded ds calf thymus (DNA) mixed in carbon nanotube paste electrode (PE) were provided. The optimum analytical conditions were determined and the peak potential was 0.2 V vs. Ag/AgCl. The linear working ranges of CV (50-75 ug/L) and SW (5-80 ng/L) were obtained. The precisions of RSD in the 10 ug/L was 0.086% (n=15) and the detection limit was 0.65 ng/L ($2.92{\times}10^{-12}M$) (S/N=3) with 300 s adsorption time at the optimum condition. The method was used to determine the presence of explosive chemicals in contaminated soil samples.

Automatic Detection System for Dangerous Abandoned Objects Based on Vision Technology (비전 기술에 기반한 위험 유기물의 자동 검출 시스템)

  • Kim, Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.69-74
    • /
    • 2009
  • Abandoned objects should be treated as possibly dangerous things for public areas until they turn out to be safe because explosive material or chemical substance is intentionally contained in them for public terrors. For large public areas such as airports or train stations, there are limits in man-power for security staffs to check all the monitors for covering the entire area under surveillance. This is the basic motivation of developing the automatic detection system for dangerous abandoned objects based on vision technology. In this research, well-known DBE is applied to stably extract background images and the HOG algorithm is adapted to discriminate between human and stuff for object classification. To show the effectiveness of the proposed system, experiments are carried out in detecting intrusion for a forbidden area and alarming for abandoned objects in a room under surveillance.

  • PDF

Detection of Explosive RDX using Parallel Plate Waveguide THz-TDS (평행판 도파관 THz 분광을 이용한 폭발물 RDX 검출)

  • Yoo, Byung Hwa;Chung, Dong Chul;Kang, Seung Beom;Kwak, Min Hwan;Kang, Gwang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1939-1943
    • /
    • 2012
  • In this paper we presented the detection of the explosive material RDX using a parallel plate waveguide (PPWG) THz time domain spectroscopy (TDS). Normally the explosive materials have been characterized through identification of vibrational fingerprint spectra. Until now, most of all THz spectroscopic measurements have been made using pellet samples where disorder effects contribute to line broadening such that individual resonances merge into relatively broad absorption features. In order to avoid such disadvantages we used the technique of PPWG THz-TDS to achieve sensitive characterization of explosive material RDX. The PPWG THz-TDS used in this work well established ultrafast optoelectronic techniques to generate and detect sub-picosecond THz pulses. The explosive material was analyzed as powder layers in $112{\mu}m$ gap of metal PPWG. The thin later mass was estimated to be about $700{\mu}g$. Finally, we showed spectra of explosives from 0.2 to 2.4 THz measured using PPWG THz-TDS.