• Title/Summary/Keyword: 폭기량

Search Result 98, Processing Time 0.025 seconds

A Study on Radon Removal Efficiencies in Drinking Water according to the Variations of Water Temperature and Aeration Rate in Small Waterwork Facility (소규모 간이상수도 시설에서 수온과 폭기량 변화에 따른 수중 라돈 제거 효율에 관한 연구)

  • Kim, Hyun Gu;Choi, Jung Soo;Joo, Hyun Jong;Kim, Sung Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.52-57
    • /
    • 2013
  • Radon, which is one of the radioactive elements in the natural world, exists in the atmosphere and water. When this element inflows into the human body, it carries the risks of developing lung cancer and stomach cancer. Therefore, in this study, an effective 10 L scaled reactor was produced to mitigate radon in water and the radon mitigation efficiency in water following the changes in water temperature and amount of aeration were evaluated. Based on this, the radon mitigation efficiency (SRRR; Specific radon removal rate) was derived per unit air volume. According to the study result, when water temperature increased from $10^{\circ}C$ to $16^{\circ}C$, the SRRR value increased from 95 $nCi/m^3{\cdot}L$ to 134.4 $nCi/m^3{\cdot}L$, and when the amount of aeration increased from 0.2 L/min to 1 L/min, the SRRR value decreased from 198.1 $nCi/m^3{\cdot}L$ to 72.2 $nCi/m^3{\cdot}L$. Therefore, based on the experimental results, it is considered that it can be applied as a examination factor and objective indicator during the design of future radon-in-water mitigation systems.

The Environmental Control of $Er^{3+}$ ions in $R-SiO_2/ZrO_2$ Sol-Gel Matrix ($R-SiO_2/ZrO_2$ 졸-겔 재료내 $Er^{3+}$이온의 결합 환경 제어)

  • 김주현;권정오;석상일;안복엽
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.224-224
    • /
    • 2003
  • 광통신을 위한 구성 요소는 빛을 발생시키는 발광소자, 빛을 검출하는 수광소자 그리고 광신호를 처리하는 광신호처리 소자로 구성된다. 이때 각 소자간 광전송과 광소자에 의한 광 신호 처리 과정에서 광전송 손실이 심각하게 일어나 광정보를 상실하게 되므로 각 요소별로 광신호 증폭이 반드시 필요하다. 뿐만 아니라 완전 광화에 의한 초고속/대용량 광통신망의 구축에는 저가이며, 광집적화가 가능한 광도파로형 광증폭기가 요구되고 있다. 짧은 거리에 높은 증폭 효율을 얻기 위한 광도파로형 광증폭기를 구현하기 위해서는 광통신 파장대인 1.55$\mu\textrm{m}$ 대역의 증폭이 가능한 Er 이온을 고농도로 도핑 할 필요가 있다. 그러나 Er 이온을 단순히 고농도로 첨가하면 Er-Er 간 뭉침 현상에 의해 더 이상의 증폭이 어렵게 된다. 본 연구에서는 이러한 문제를 해결하면서 스핀 코팅이 가능하여 저가 공정이 가능한 유/무기 졸-겔 재료 내에 Er 이온을 제어된 방법으로 첨가하고 그 결합 환경을 FT-IR 및 $^{17}$ O-NMR로 분석하였다. 유/무기 졸겔 재료 제조를 위하여 먼저 MPTS(MethAcryoxyPropylTrimethoxySilane)를 부분 가수분해한 후 ZrOCl$_2$.8$_2$O (Zirconyl Chloride Octahydrate) 와 ErCl$_3$. 6$H_2O$ (Erbium(III) Chloride Hexahydrate)를 순차적으로 결합시키고, Zr/MPTS 및 Zr/Er의 첨가비에 따른 발광 특성을 PL(photoluminescence) 스팩트럼으로 분석하여 Er 이온의 주위 결합 환경이 PL에 미치는 영향을 조사하였다. 또한 Si 기판에 코팅한 Er이 도핑된 유/무기 하이브리드 졸-겔 코팅막의 굴절율 등 광도파로 재료로서의 특성도 프리즘 커플러 등을 이용하여 조사하였다.

  • PDF

Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage (막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.20-30
    • /
    • 2014
  • A membrane-coupled sequencing batch reactor (MSBR) was used for the advanced treatment of rural village sewage which is very low C/N ratio. The effect of powdered activated carbon, aeration rate, and external organic material loadings on the treatment efficiency and filtration performance were investigated in sequencing batch reactor, in which a flat-sheet type microfiltration membrane with a pore size of $0.4{\mu}m$ was submerged. At the initial operation (within 54 days) MLSS concentration, and the removal efficiencies of COD, T-N, and T-P were increased with the increase of C/N ratio. After 89 days the removal efficiencies of COD, T-N, and T-P were 97.1%, 75.0%, and 48.3%, respectively. Suspended solid-free effluent was obtained by membrane filtration. The T-P removal was relatively low because of depending on the amount of excess sludge wasting. During the operation of MSBR with powdered activated carbon, the particle size of the sludge reduced by the increase of collision frequency and mixing intensity. In comparison with MSBR without powdered activated carbon, TMP of MSBR with that was significantly elevated.

Modeling of Foam Separator for Sea Water Treatment (해수 포말분리공정의 해석 및 모델)

  • HUR Hyun-Chul;SEO Jae-Koan;PARK Eun-ju;KIM Sung-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.165-169
    • /
    • 1999
  • Experiments were conducted to evaluate a experimental model developed for the protein removal by foam separation. The foam separator was operated in well-mixed tank which would be considered as a completely mixed condition. The feasibility of foam separation to remove protein from sea water was investigated. Protein removal characteristics of the foam separator were obtained by batch experiments. To find the effect of the operating parameter to protein removal rate, the foam separation was carried with variation of initial protein concentration and superficial air velocity. The result indicated that the protein removal efficiency was increased with increasing protein concentration and superficial air velocity. The relationship between operation parameters and protein removal rate were evaluated by non-linear regression as the form of exponential function, Using both relationships, the simplified model was determined. The simplified foam separator operation model was verified by the batch operation. The simulation results showed a good relationship with the experimental data.

  • PDF

Optimal DO Setpoint Decision and Electric Cost Saving in Aerobic Reactor Using Respirometer and Air Blower Control (호흡률 및 송풍기 제어 기반 포기조 최적 DO 농도 설정과 전력 비용 절감 연구)

  • Lee, Kwang Su;Kim, Minhan;Kim, Jongrack;Yoo, Changkyoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.581-586
    • /
    • 2014
  • Main objects for wastewater treatment operation are to maintain effluent water quality and minimize operation cost. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. The oxygen uptake rate (OUR) is real-time measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO set-point needed for the micro-organism is suggested based on real-time measurement of oxygen uptake of micro-organism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal set-point decision system by providing the necessary oxygen supply requirement to the micro-organisms coping with the variations of influent loading.

Composting Effectiveness of A Sundry System with A Bin-type Composter for Recyle of Animal Wastes (축분뇨처리를 위한 Bin형 부숙조- Sundry 시스템의 퇴비화효율 평가)

  • 최홍림;김현태;정영윤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.92-103
    • /
    • 1993
  • A sunday system with a horizontal bin-type composter was constructed and operated to evaluate its composting performance for four days for each test in October, 1992. A sundry system is one of popular systems for composting livestock manure, of which main benefit is to utilize unlimited, clean, and free solar radiation. A rectangular concrete bin(composter) with dimension of 300cm(length) X90cm(width) X60cm(height) was bedded alternatively with four lanes of aeration pipes and heating pipes, and was insulated at three walls with 50mm styrofoam. Each aeration pipe of a diameter of 25mm had 4mm perforated holes at every 15cm longitudinally, and supplied air of about 2m$^3$/min to the composter to maintain aerobic condition . A stirrer rotating at 1 rpm made one round trip every 20 minutes on the conveying chain along the the length of the composter. Five tests (Test 1~Test 5) were implemented to evaluate the composting effectiveness of a sundry system with a horizontal bin-type composter. Treatments of two levels of the mixture ratio of swine manure and paper sludge cakes(manure : paper sludge cakes= 1 : 4 and 1 : 2) and two levels of the water content(W/C ; 70% and 50%) were made to test the significance of the physicochemical properties for decomposition of the mixture materials. Temperature, C/N ratio, water content, microbial activity of the composting materials were taken measurements to evaluate its performance with the lapse of composting time for tests. A small-scale sundry system with a bin-type composter did not appear to be an appropriate system for composting livestock manure. Since heat generation by the composting materials could not overcome heat loss due to areation in a small-scale composter, a proper thermal enviroment could not be maintained to propagate massively thermopilic microorganism relatively in a short period of time. Different from the result of Chol et al.(1992) 6), a temperature variation of the composting materials did not show the peak clearly and C/N ratio didn't lower with time as expected. Mesophilic microoragnism seemed to play an important role for decomposition of the mixture materials. A sundry system with a bin-type composter may be good for a large-scale livestock farm household which may produce enough animal manure. Therefore a decision should be made very carefully to choose a system for composting livestock waste.

  • PDF

A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant (하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출)

  • Kim, Min Han;Ji, Seung Hee;Jang, Jung Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • It is important to keep stable effluent water quality and minimize operation cost in biological wastewater treatment plant. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. For optimal control, The oxygen uptake rate (OUR) is realtime measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO seT-Point needed for the microorganism is suggested based on real time measurement of oxygen uptake of microorganism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal setpoint decision system by providing the necessary oxygen supply requirement to the microorganisms coping with the variations of influent loading.

Phosphorus and Nitrogen Reduction from Animal Wastewater with MAP Process (축산폐수에서 질소$\cdot$인의 추출을 위한 MAP공정 개발)

  • Oh I. H.;Lee J. H.;Jeung D. S.;Jo J. W.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.207-214
    • /
    • 2005
  • To reduce phosphorus and nitrogen from the swine wastewater, magnesium chloride $(MgCl_2)$ was used as a reaction material for both soluble phosphorus (SP) and ammonia-nitrogen (AN). The initial value of SP content were $471mg/\ell$ far aeration test and $515 mg/\ell$ for NaOH addition test, but treatment of $MgCl_2$ reduced SP value to $5mg/\ell$ and $4mg/\ell$. The removal efficiency of $MgCl_2$ for SP showed $99\%$ in both treatment, and the removal efficiency of $MgCl_2$ for AN showed $15\%$ with treatment of aeration and $18\%$ with NaOH. All the experiments were done in a low temperature of 6 to $8^{\circ}C$, suggesting that this methods are possibly able to apply to a cold weather conditions. Moreover, the struvite crystal structure was identified by electronic microscope, implying that $MgCl_2$ is an effective material for removal of SP from swine wastewater In addition to the increased removal rate of the AN in wastewater, both $MgCl_2$ and $KH_2PO_4$ were added. The SP value was reduced by $99\%$ with 2g addition of the phosphate. The SP removal rate by 4g addition of the phosphate was increased only as $15-19\%$, but the quantity of removed SP was higher than that of 2g addition test. The value of AN was not reduced as expected by adding $KH_2PO_4$. The AN removal rate were low as $18\%$ and $15\%$ like as the level of the former test with $MgCl_2$ alone. Therefore, it is needed to examine closely the reaction mechanism f3r reducing both SP and AN simultaneously.

  • PDF

Development of an Solid Separation System for Pig Slurry (돈 슬러리용 고형물 분리시스템 개발)

  • 김민균;김태일;최동윤;백광수;박진기;양창범;탁태영
    • Journal of Animal Environmental Science
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • This study was conducted to develope the new solid separating system which can be efficiently and economically removed the solid parts in high pollutants concentration of pig slurry. The pollutants concentration, BOD$_{5}$ , COD and SS of the slurry used in this study was 15,990($\pm$2,389)mg/l, 20,004($\pm$5,512)mg/l and 26,486($\pm$5,935)mg/l, respectively. After removal of solid part in slurry, the pollutants concentration, BOD$_{5}$, COD and SS was change into 5,617($\pm$690)mg/l, 5,553($\pm$633)mg/land 1,456($\pm$341)mg/l, respectively in the Fixed biological membrane tank. The reduction of the pollutants concentration of suspend liquid through membrane will be allowed to greatly improve the water purification by an Activated sludge method. This separating system consisted of a temporary storage, a circulating tank and a Fixed Biological membrane tank. A temporary storage which has a draining system of screw type and an aeration device played a tremendous role in draining the solid by filled an aeration of 0.3 l/min. A Fixed Biological membrane tank of which a styrofoam filled in a 2/3 volume as a Biological media was fixed by a stainless steel net (pore size : 0.5mm) to separate the liquid layer of influx in them. The separating system efficiency factors were the speed of screw motor, cycle number of slurries in a circulating tank and moisture contents of solid effluent through the screw path. Although the pollutants concentration was very variable in temporary storage, the final concentration of $BOD_5$ and SS, except COD of the suspended liquid in a Fixed biological membrane were not different regardless of cycle number of a circulating tank. Moisture contents of effluent from temporary storage was 73% under the speed 1 ppm of screw motor and 62% under the 1/4rpm of it.

  • PDF

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).